Фрагмент инструкции


This document provides information about the B.11.31.1003 (AR1003) of the HP IB4X-00 driver
for InfiniBand.
IB4X-00 Driver for InfiniBand overview
This document details defect fixes made to the IB4X-00 Driver for InfiniBand on HP-UX 11i v3
for the B.11.31.1003 release.
New and changed features in this release
New features
The following feature is new with the B.11.31.1003 version of the IB4X-00 Driver for InfiniBand:

There are no new features with this release.
Changed features
The following feature has been changed with the B.11.31.1003 version of the IB4X-00 Driver for
InfiniBand:

There are no changed features with this release.
Known problems fixed in this version
Table 1 lists the issues that have been fixed in the IB4X-00 Driver for InfiniBand HP-UX 11i v3
March 2010 (AR1003) release. To view the entire details of each issue fix, refer to the HP IT
Resource Center at: http://forums1.itrc.hp.com/service/forums/home.do
Table 1 HP-UX March 2010 (AR1003) Fixes
Defect ID
Description
QXCR1000968186
Opening device file resulted in a system panic. This occurred regardless of
whether or not the IB adapter was installed. This problem has now been fixed.
Table 2 HP-UX September 2009 (WR0909) Fixes
Defect ID
Description
QXCR1000940168
The DART81 BA929AA 11iv3 VSE OE software with InfiniBand adapter 448397-B21 failed to
boot at the ESWL_IGNITEUX stage, due to timeout at iux_monitor_reboot. The driver code
has been modified to resolve this issue.
QXCR1000946862
The new ituil command option, x, has been provided to display the link speed of an InfiniBand
interface.
QXCR1000938720
In the cluster environment, where HP-UX and Linux nodes are connected to the switch,
whenever the HP-UX node reboots, there is an LID change at the HP-UX node, which is
non-compliant with InfiniBand subnet manager protocol.
QXCR1000938766
The PM subsystem in the InfiniBand driver is not responding to ClassPortInfo requests.
For this reason, some of the Linux/OFED tools generate an error when there is an HP-UX host
in the cluster. The tools affected are:
ibcheckerrs
ibcheckerrors
ibdatacounters
ibclearcounters
ibclearerrors
QXCR1000962014
There is a shutdown error during CVA, due to an issue with the RDMA/InfiniBand Driver
Control Script.