Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Addtron Technology, модель Firewall VPN DSL/Cable Router with 4-Port Switch TELEWELL TW-640

Производитель: Addtron Technology
Размер: 793.44 kb
Название файла: 5706332e-d247-4ab8-beeb-1cf877a7f5f4.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Default settings: DHCP client of TW-640 will take 1 IP address from ADSL operator with TW-EA701 modem. DHCP server will share automatically 1 IP for workstations. NAT protocoll is used as on default. DHCP client has to be default in workstations. Billion BIPAC-640 DSL/Cable IP-Sharing Router TELEWELL TW-640 Features SOHO firewall to automatically detect and block the DoS (Denial of Service) attack. Security logging for hacker’s attack with timestamp. All PCs in a LAN can share the connection using one ISP account. Support VPN (PPTP client or IPSec & PPTP pass through) to provide a secure Internet connection Software DMZ host setting. Web-based Firmware upgrade. Web-based configuration and Management. Remote configuration and management from WAN interface. 4 ports 10/100 Mbps N-way Ethernet Switch. Quick Start Guide Automatic MDI/MDIX crossover for 100BASE-TX and 10BASE-T ports. Support Fast Ethernet Switch Function. PPP over Ethernet (PPPoE) support for DSL connection. NAT for sharing single IP address DHCP Server and Client. DHCP server allocates up to 253 client IP addresses. SNTP for getting network real time clock. Internet applications such as Web browser, ICQ, FTP, Telnet, E-Mail, AoE, News, NetMeeting, Ping, mIRC, AOE, VDOLive Player, PCAnyWhere… DNS relay. Virtual server. Rich packet filters Support Windows 95 / 98 / ME / NT / 2000 / XP, Unix, and Mac. Billion BIPAC-640 DSL/Cable IP-Sharing Router The Front Panel LEDs 1 2 3 4 5 6 7 LED Meaning 1 Power Lit green when AC power is connected. 2 LAN 1 3 LAN 2 Lit green when connected at 100 Mbps. 4 LAN 3 Lit orange when connected at 10 Mbps. 5 LAN 4 Flashes when sending/receiving data. 6 WAN Lit when connected to a WAN device. Flashes when sending/receiving data. Lit green when using PPPoE. 7 PPP/SYS Lit orange when system ready. Quick Start Guide The Rear Ports Power Connect the supplied power (jack) adapter to this jack. Connect an UTP Ethernet cable Global or crossover cable to this port when connecting to the Internet (RJ-45 or making other WAN connector) connections. Connect an UTP Ethernet cable Local 1- 4 to this four ports when (RJ-45 connecting to a LAN of connector) 10Mbps or 100Mbps such as an office or home network. Connecting the TELEWELL TW-640 Refer to the following to connect the TELEWELL TW-640 to a WAN (Wide Area Network) and a LAN (Local Area Network): 1. Connect the TELEWELL TW-640 as shown below. 2. Power on the device. 3. Ensure the Power, LAN, and WAN LEDs are lit. Billion BIPAC-640 DSL/Cable IP-Sharing Router 6 AC Power Adapter UTP Ethernet standard cross-over cable #4 (Midx\Mdi) can be connected to a Hub or Workstation RJ-45 UTP network cable Configuring PC in Windows 95/98/ME 1. Go to Start/Settings/Control Panel. In the Control Panel double-click on Network and choose the Configuration tab. 2. Select TCP/IP -> NE2000 Compatible, or any Network Interface Card (NIC) in your PC. Quick Start Guide 3. Select the Obtain an IP address automatically radio button. 4. Then select the DNS Configuration tab. 5. Select the Disable DNS radio button and click Ok to finish the configuration. Configuring PC in Windows NT4.0 1. Go to Start/Settings/Control Panel. In the Control Panel double- click on Network and choose the Protocols tab. 2. Select TCP/IP Protocol and click Properties. Billion BIPAC-640 DSL/Cable IP-Sharing Router 3. Select the Obtain an IP address from a DHCP server radio button and click Ok. Configuring PC in Windows 2000/Xp 1. Go to Start/Settings/Control Panel. In the Control Panel double-click on Network and Dial-up Connections. 2. Double-click Local Area Connection. 3. In the Local Area Connection Status window click Properties. Quick Start Guide 4. Select Internet Protocol (TCP/IP) and click Properties. 5. Select the Obtain an IP address automatically and the Obtain DNS server address automatically radio buttons. 6. Click Ok to finish the configuration. Billion BIPAC-640 DSL/Cable IP-Sharing Router Configuring the TELEWELL TW-640 To configure this device, you must have IE 4.01 or above installed. 1. Open web browser and type in the browser’s address box. This number is the default IP address for this router. Press Enter. 2. A user name and password prompt will appear. Click Ok. Default is; No user name and password) Checnge in System / Password area and write down the new password. 3. Select from the following: ..xDSL user (Dynamic): Users who are using PPPoE. Quick Start Guide .. Cable users (Dynamic): Users who do not have static IP addresses from their ISPs. . . xDSL/Cable users (Static): Users who have obtained at least one dedicated IP address from an ISP. Please also check that DNS setting is ccorrect (Automatic is the best setting). Billion BIPAC-640 DSL/Cable IP-Sharing Router 4. Click Apply to store all configurations. The device will reboot automatically. Connecting to the Internet To see if the IP sharing router is visible on the local network, go to Start/Run. In the Run dialog box type “Pi...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории