Фрагмент инструкции


This module consists of a B-size component card (labeled E1345-66201) and a screw terminal block that plugs onto the component card. The E1345A is functionally similar to the E1347A. The E1345A multiplexer is arranged into two banks of eight switches, each having its own common high, low, and guard screw terminals accessible on the terminal block. Tree- switched common high, low, and guard screw terminals and analog bus connections provide access to all 16 channels. The module may be programmed as either a single 1x16 three-wire multiplexer, two independent 1x8 three-wire multiplexers (for four-wire W ), or a 1x8 six-wire multiplexer. Refer to the Agilent Technologies Website for instrument driver availability and downloading instructions, as well as for recent product updates, if applicable. Configuration One analog bus cable is shipped with each module, making it easy to connect common outputs together for slot-adjacent modules. If you are using a B-size mainframe, Agilent E1300B or E1301B, use the analog bus cable shipped with the E1326B DMM to connect it to the multiplexer(s). C-size Adapter For installing the E1345A in a C-size mainframe, the E1403C active adapter is recommended. PDFINFO H5601 -01 Product Specifications Input DC: Maximum voltage (any terminal to any other terminal or chassis): AC rms: Maximum voltage (any terminal to any other terminal or chassis): Maximum current (per channel common, non- inductive): Maximum power per channel: 120 Vdc 120 V rms 50 mA 1 VA DC Maximum thermal offset per channel, differential Hi-Lo: 4 m V Closed channel resistance: 100 W ± 10% Insulation resistance (between any two points): 10E9 W Insulation resistance (Hi to Lo, power off): n/a AC Minimum bandwidth (-3 dB, 50 W source/load): 10 MHz (protection resistors shorted) Crosstalk (channel-tochannel): 100 kHz: ±70 dB 10 MHz: ±20 dB Both: n/a Closed channel <150 pF Hi-Lo, <150 pF Lo-Guard, <2000 pF capacitance: Guard-Chassis General Characteristics Relays: Minimum relay life: No load: Rated load: Screw terminal wire size: Scanning rate: Reed relays Break-before-make Relays open on power down Relays open on power up 10E8 operations 10E7 operations 16 to 26 AWG (1.5, 1.2, 0.9, 0.75, 0.5 mm) 600 channels/s typ. General Specifications VXI Characteristics VXI device type: Register based, A16, slave only Size: B Slots: 1 Connectors: P1 Shared memory: None VXI busses: None C-size compatibility: Requires E1403C Instrument Drivers See the Agilent Technologies Website (inst_drivers) for driver availability and downloading. Command module firmware: Downloadable Command module firmware rev: A.01 I-SCPI Win 3.1: Yes I-SCPI Series 700: Yes C-SCPI LynxOS: Yes C-SCPI Series 700: Yes Panel Drivers: Yes VXIplug&playWin Framework: Yes plug&playWin 95/NT Framework: Yes VXIplug&playHP-UX Framework: No PDFINFOH5601 -02 Module Current IPM IDM +5 V: 0.2 0.01 +12 V: 0.13 0.01 ±12 V: 0 0 +24 V: 0 0 ±24 V: 0 0 ±5.2 V 0 0 ±2 V: 0 0 Cooling/Slot Analog bus cables for MUX-to-MUX and MUX-to-multimeter Watts/slot: 1.00 connections D P mm H2O: 0.02 Air Flow liter/s: 0.10 Ordering Information Description Product No. 16-Channel Low-Offset Relay Multiplexer E1345A Service Manual E1345A 0B3 Japan - Japanese Localization E1345A ABJ 3 Yr. Retn. to Agilent to 1 Yr. OnSite Warr. E1345A W01 Extra terminal block for the E1345A E1345-80001 Analog bus cables for MUX-to-MUX and MUX-to-multimeter connections PDFINFOH5601 -03 Signal Conditioning Components/Current Shunt PDFINFOH5601 -04 Related Literature 2000 Test System and VXI Catalog CD-ROM, Agilent Pub. No. 5980-0308E (detailed specifications for VXI products) 2000 Test System and VXI Catalog, Agilent Pub. No. 5980-0307E (overview of VXI products ) 1998 Test System and VXI Products Data Book, Agilent Pub. No. 5966-2812E Online Internet access for Agilent product information, services and support VXI product information Defense Electronics Applications Agilent Technologies VXI Channel Partners Agilent Technologies' HP VEE Application Website Agilent Technologies Data Acquisition and Control Website Agilent Technologies Instrument Driver Downloads Agilent Technologies Electronics Manufacturing Test Solutions Get assistance with all your test and measurement needs at or check your local phone book for the Agilent office near you. Agilent Technologies' test and measurement service/support commitment Agilent strives to maximize the value our test and measurement products give you, while minimizing your risk and service/support problems. We work to ensure that each product is realistically described in the literature, meets its stated performance and functionality, has a clearly stated global warranty, and is supported ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории