Инструкция по эксплуатации Agilent Technologies, модель 34980A

Производитель: Agilent Technologies
Размер: 596.6 kb
Название файла: 57b85b3b-1170-4bd5-9386-eb47abfbfa8b.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


All three Input/Output interface connections come standard with the 34980A mainframe. If you choose to modify or upgrade your test system I/O, the 34980A is system ready. You can also easily control the 34980A without connecting to a PC by pressing the front-panel buttons, an advantage when first setting up or troubleshooting a system. Upgrading your test system from using the 3499A/B/C GPIB to the 34980A GPIB, or newer USB or LAN is quick and easy. If you have used I/O Config from the Agilent I/O Libraries to set your GPIB instrument connection, you would use the same I/O Config to set up your LAN or “TCPIP” instrument connection. Retrieve the LAN, TCPIP address from your instrument and enter it into I/O Config. When you address your instrument in a program, it will look similar to; TCPIP0::9::INSTR. For more information on connecting to Agilent instruments you can access the Agilent Technologies USB/LAN/GPIB Interfaces Connectivity Guide at With LAN, the instrument can be located closer to the device under test without worrying about the distance to the PC. A USB to instrument connection is even easier. The computer automatically detects instruments that are USB ready. If you are currently using the 3499A/B/C RS232 interface, it is recommended to upgrade to the 34980A GPIB, USB or LAN interface to achieve optimal data transfer rates. Instrument Control (Programming) The 34980A and 3499A/B/C can both be controlled locally from the front panel, or by sending either instrument or driver commands from a PC for remote control. The 34980A’s instrument commands and drivers are based on modern standards such as SCPI (standard commands for programmable instruments) and IVI-C and IVI COM drivers. The SCPI instrument commands of the 34980A are similar to the 3499A/B/C’s but they are not interchangeable. A comparison of the commands is provided in appendix A. The 34980A's IVI-C and IVI-COM drivers are similar to Plug & Play drivers, the 3499A/B/C's Plug & Play driver for example, but include improvements. The IVI (Interchangeable Virtual Instruments) driver specification was built upon the Plug&Play driver specification but adds the capabilities provided by the Microsoft ActiveX technologies which simplify instrument interchangeability, and product performance. The 34980A also includes many new commands for the operation of the embedded DMM. A 34980A Web interface provides a new easy way to communicate via LAN with the instrument. Table 3 shows a summary of the programming control options available for the 3499A/B/C and the 34980A. There is similarity between the instrument commands, however, the 34980A has evolved to use the most modern and widely accepted instrument command standards. Table 3. Control Options for 3499A/B/C and 34980A 3499A/B/C 34980A Front Panel Buttons 3488 Legacy Commands SCPI Commands Plug & Play driver IVI COM driver IVI-C driver Web Interface LabVIEW driver Listed below are each of the many ways available to communicate and control the 34980A, the communication options and their description Web Page Interface The 34980A comes with a built-in detailed instrument web page that allows you to remotely connect and communicate with the mainframe and installed modules. You establish a LAN connection, either directly between the 34980A and PC, or from the 34980A to an existing Local Area Network. The instrument Web page resides on the 34980A and can be accessed using a standard web browser such as Netscape or Internet Explorer on a PC. Just type the IP address into the web browser. The web interface allows you to select any of the installed modules and view the current configuration, change settings, make measurements, and makes it easy to troubleshoot or debug the switch/measure system. The instrument web interface also allows you to check the current status of the instrument by viewing the error queue, calibration status and the accumulated module switch closures. Web interface display for 34921A MUX Switch module Web interface display of scanned measurements SCPI Commands The 34980A can be programmed using SCPI commands or the IEEE standard commands. Configuration, measurements and system control of the mainframe and modules are easily achieved using these instrument commands. One difference between instrument commands for the 3499A/B/C and the 34980A relates to addressing specific channels in the system. Table 4 shows an example difference in 3499A/B/C switch control commands compared to 34980A commands. Notice the 34980A uses four digits to address the module slot number and channel(s) rather than only three digits as the 3499A/B/C uses. Also, for the 3499A/B/C the [ROUTe] in the command structure is optional, where with the 34980A it is required. The 34980A offers new measurement and module capabilities such as counter/timer and digital I/O with pattern generator/detector that use commands unique to their functionality. Appendix A includes a list of the ...

Эта инструкция также подходит к моделям:
Сетевое оборудование - 34980A (596.6 kb)
Сетевое оборудование - 3499A/B/C (596.6 kb)
Сетевое оборудование - 3499A/B/C (596.6 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории