Войти:
Оценок - 5, средний балл: 4.2 ( )

Инструкция по эксплуатации Adder Technology, модель SV16PRO

Производитель: Adder Technology
Размер: 1.64 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


To abandon editing press ESC. Selecting a computer on the menu list With the menu visible on the screen, highlight the computer to be selected using the cursor up/down or page up/down keys as required. Press the ENTER key to switch to the highlighted computer. SmartView Pro has an advanced ‘connection confirmation’ facility which is particularly useful in systems where many computers are displaying the same or very similar video. The selected computer name and port number will briefly flash up on the screen to confirm the selection has been made. If it is not possible to make the connection, perhaps because a cascaded unit is not switched on or is in use locally, the menu will flash ‘computer unavailable’ until the ESC key is pressed. SmartView Installation and Use Page 26 Summary of keys used by the menu and their function ‘HOTKEYs’ and ‘M’ - calls the menu up onto the screen (even if no PC video exists) ‘INSERT’ - adds a computer entry AFTER the currently selected line ‘SHIFT’ and ‘INSERT’ - adds a computer entry BEFORE the currently selected line ‘DELETE’ - deletes the currently selected computer ‘SHIFT’ and ‘DELETE’ - edits the currently selected computer ‘ENTER’ - confirms an entry or selects a computer ‘ESC’ - quits from editing a line or quits from the menu ‘up arrow’ - moves up the menu by one line ‘down arrow’ - moves down the menu by one line ‘page up’ - moves to the top of the menu page, or up 8 lines if more than 8 present ‘page down’ - moves to bottom of page or down 8 lines if more than 8 present 3.8 Mouse control The channels can conveniently be changed on SmartView Pro by using a three button mouse or IntelliMouse. In order to switch to the next channel simply hold down the central mouse button or wheel button and click on the left hand mouse button. The channel will then change. 3.9 RS232 control SmartView Pro can be controlled by a remote RS232 device. To select a channel the data rate of the sending device must be set to 1200 baud, 8 bits, no parity and 1 stop bit. No handshaking is used by the SmartView Pro. Simply send the character for the channel which needs to be selected, for example ASCII ‘1’ (hex code 31) will select channel 1, ASCII ‘2’ (hex code 32) will select channel 2 and so on. Ports 10,11,12,13.14.15 and 16 are selected by sending ASCII codes A,B,C,D,E,F and G respectively. 3.10 Cascading SmartViews Any number of SmartView Pro switches can be connected together to expand the number of connected computers. This can be particularly useful where clusters of computers are located some distance from each other because each unit acts as data booster and can each be up to 30 metres away from the next SmartView. The channel can be selected on remote SmartView units using an extension of the HOTKEY control function or using the On Screen Menu which will store over 300 SmartView Installation and Use Page 27 names. The On Screen Menu is recommended for selecting computers on cascaded SmartViews as this avoids the need to use long hotkey sequences that may be hard to remember. When using the On Screen Menu, limit the cascade depth to three levels (the maximum number of port digits that can be added to the menu). For example, consider a situation where two SmartView Pro units are connected together as shown below. To connect to the computer attached to port 3 on SmartView B the user would hold down the hotkey keys then press ‘2’ followed by ‘3’, whilst keeping the hotkey keys pressed. This will have the effect of connecting to port ‘3’ of the SmartView which is connected into port ‘2’ of the first SmartView unit A. (note: if you are cascading 12 and 16 port units then you will need to type a leading 0 before all single digit port numbers). For example to connect to port 3 on the SmartView SV8PRO cascaded off port 2 of your first SmartView SV8PRO use: press ba baba2 22release 2 22 press 3 33release 3 33ba baba For example to connect to port 14 on the SmartView SV16PRO cascaded off port 1 of your first SmartView SV16PRO use: press ba baba0 00release 0 00 press 1 11release 1 11 press 1 11release 1 11 press 4 44release 4 44ba baba SmartView Installation and Use Page 28 A typical cascade of two SmartViews SmartView Installation and Use Page 29 4. SmartView configuration options All the options described in this section are entered in SmartView configure mode see section 2.5 for instructions on entering configure mode. 4.1 Screen saver time delay SmartView contains a programmable screen saver which will blank the display after the set time delay with no keyboard or mouse activity. Simply typing at the keyboard or moving the mouse will re-enable the display. The display will flash whilst the SmartView is in screen save mode. B1 - screen saver disabled (default) B2 - Blank screen after 1 minute of inactivity B3 - Blank screen after 2 minutes of inactivity B4 - Blank screen after 4 minutes of inactivity B5 - Blank screen after 8 minutes of inactivity B6 - Blank screen after 12 minutes of inactiv...

Эта инструкция также подходит к моделям:
Сетевое оборудование - SV12PRO (1.64 mb)
Сетевое оборудование - SV4PRO (1.64 mb)
Сетевое оборудование - SV8PRO (1.64 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории