Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации ADTRAN, модель Threat Analysis Reporter TAR

Производитель: ADTRAN
Размер: 3.18 mb
Название файла: 685c6c7c-8352-4850-8fa4-2b2b822dfeab.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


2. Align the four (4) square holes on the right inner slide against the hooks on the right side of the chassis as show below on the left. 3. Securely attach the slide to the chassis with two M4 flat head screws and repeat the steps 1-3 to install the left inner slide to the left side of the chassis. Install the Outer Slides 1. Measure the distance from the front rail of the rack to the rear rail of the rack. 2. Attach a short bracket to the rear side of the right outer slide, and a long bracket to the front side of the right outer slide as shown above on the right. 3. Adjust the short and long brackets to the proper distance so that the chassis can snugly fit into the rack. 4. Secure the slides to the cabinet with screws. 5. Repeat steps 1-4 for the left outer slide. Install the Slide Assemblies to the Rack 1. After you have installed the short and long brackets to the outer slides, you are ready to install the whole slide assemblies (outer slides with short and long brackets attached) to the rack. (See the previous page.) 2. Use M5 screws and washers to secure the slide assemblies into the rack as shown below: Install the Chassis into the Rack 1. Push the inner slides, which are attached to the chassis, into the grooves of the outer slide assemblies that are installed in the rack as shown below: 2. Push the chassis all the way to the back of the outer slide assemblies as shown below: Rack Mount Instructions for MSA Servers Optional: Install the Chassis Rails NOTE: If your chassis does not come with chassis rails, please follow the procedure listed on the last page of this sub-section to install the unit directly into the rack. CAUTION: Please make sure that the chassis covers and chassis rails are installed on the chassis before you install the chassis into the rack. To avoid personal injury and property damage, please carefully follow all the safety steps listed below: Before installing the chassis rails: • Close the chassis using the chassis cover. • Unplug the AC power cord(s). • Remove all external devices and connectors. 1. Included in the shipping package are a pair of rail assemblies. In each rail assembly, locate the inner rail and the outer rail. 2. Press the locking tab to release the inner rail from its locking position and pull out the inner rail from the rail assembly. NOTE: The inner rails are to be attached to the chassis and the outer rails are to be installed in the rack. 3. Locate the three holes on each side of the chassis and locate the three corresponding holes on each of the inner rail. 4. Attach an inner rail to each side of the chassis and secure the inner rail to the chassis by inserting three Type G screws through the holes on each side of the chassis and the inner rail. (See the diagram below for a description of the Type G screw.) 5. Repeat the above steps to install the other rail on the chassis. Optional: Install the Traditional UP Racks After you have installed the inner rails on the chassis, you are ready to install the outer rails of rail assemblies to the rack. NOTE: The rails are designed to fit in the racks with the depth of 28” to 33”. • Determine the placement of each component in the rack before you install the rails. • Install the heaviest server components on the bottom of the rack first, and then work up. 1. In the package, locate a pair of front (short) and rear (long) brackets. Please note that the brackets are marked with Up/Front Arrows (front) and Up/Rear arrows (rear). 2. Secure the front (short) bracket (marked with the Up/Front arrows) to the outer rail with two Type G screws. (See the previous page for a description of the Type G screw.) 3. Attach the rear (long) bracket to the other end of the outer rail and secure the rear (long) bracket to the outer rail with a Type G screw as shown below. 4. Measure the depth of your rack and adjust the length of the rails accordingly. 5. Repeat the same steps to install the other outer rail on the chassis. 6. Secure both outer rail assemblies to the rack with Type H screws and Type I washers. (See the previous page for descriptions of Type H and Type I hardware components.) 7. Slide the chassis into the rack as shown below. NOTE: The chassis may not slide into the rack smoothly or easily when installed the first time. Some adjustment to the slide assemblies might be needed for easy installation. 8. You will need to release the safety taps on both sides of the chassis in order to completely remove the chassis out of the rack. Optional: Install the Open Racks After you have installed the inner rails on the chassis, you are ready to install the outer rails of rail assemblies to the rack. NOTE: The rails are designed to fit in the racks with the depth of 28” to 33”. • Determine the placement of each component in the rack before you install the rails. • Install the heaviest server components on the bottom of the rack first, and then work up. 1. In the package, locate a pair of front (short) and rear (long) brackets. Please...

Эта инструкция также подходит к моделям:
Сетевое оборудование - Threat Analysis Reporter TAR (3.18 mb)
Сетевое оборудование - Threat Analysis Reporter TAR (3.18 mb)
Сетевое оборудование - Threat Analysis Reporter TAR (3.18 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории