Войти:
Оценок - 3, средний балл: 5 ( )

Инструкция по эксплуатации Aube Technologies, модель TI035

Производитель: Aube Technologies
Размер: 584.59 kb
Название файла: TI035.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


If you have entered your city’s parameters (see section 7), the parameters P1 ON and P2 OFF show the sunset time and sunrise time for this time of the year. If the timer is used for lighting, when placed in AUTO mode, it will turn the light ON at sunset and will turn it Off at sunrise. For example: P1 ON : 20:38 (sunset) P1 OFF : --:-- (blank) P2 ON : --:-- (blank) P2 OFF : 6:10 (sunrise) • Press the HOUR and MIN buttons to set the time. Example: If you want your lights to turn On at sunset and to turn Off at 10:00 PM, set P1 OFF to 22:00. If you also want your lights to turn back On at 5:00 AM then turn Off at sunrise, set P2 ON to 5:00. P1 ON : 20:38 (sunset) P1 OFF : 22:00 (programmed) P2 ON : 5:00 (programmed) P2 OFF : 6:10 (sunrise) NOTE: P1 OFF and P2 OFF have priority over P1 ON and P2 ON respectively. For example, if sunrise is at 4:58 and P2 ON is set to 5:00, the lights will not turn on. You can replace the sunrise and sunset times by fixed times. Select program P1 ON or P2 OFF and enter the desired time using the HOUR and MIN buttons. • Press one of the control buttons or close the switch door to return to normal operation. Clearing a programmed time • Press the PGM button to display the programmed time. • Press the CODE button. The time will be erased and -:--will be displayed. NOTE: For P1 ON and P2 OFF, if you have programmed the city parameters, the programmed time will be replaced by sunset time and sunrise time respectively. • Press one of the control buttons or close the switch door to return to normal operation. • Troubleshooting Blank display • Verify circuit breaker at main panel. • Ensure the ON/OFF selector is at ON. • Reset the switch using a paper clip. Faded or irregular display Ambient temperature below freezing point Cannot switch between 24hour format and 12-hour format First, press one of the control buttons so that MAN or AUTO appears on display. Programs do not run as expected • Make sure the switch is properly programmed. • Note that -:-- indicates an inactive program, 00:00 indicates midnight. • If the switch has been configured for 12-hour format, check that PM appears on the left side of the screen when an afternoon time is displayed. The switch resets itself without apparent reason when used to control an inductive load such as a relay or a contactor. The reset is caused by the load. Install a snubber (AC130-03) at each relay/contactor. After I have bypassed the Any temporary bypass is cancelled at midnight. program to turn the light Off, Thus, the light has turned back On, the state the it turns back On at midnight. light should be at midnight according to the program. If you often bypass programming before midnight, you should program P1 OFF to midnight or earlier. This ensures that the light will remain Off when you bypass programming. • Technical Specifications Supply: 120 VAC, 50 / 60 Hz Maximum load: 2400 watts resistive or inductive, 1 HP motor Operating temperature range: 5°F to 122°F (-15°C to 50°C) Storage temperature range: -4°F to 122°F (-20°C to 50°C) Power outage: The programs are protected by a rechargeable battery. The screen is blank during the power outage. Solar table precision: +/- 11 min. (max error around poles) Certifications: CSA & UL TI035 400-035-001-C 13/3/07 2/2 TI034-3W / TI035 Addendum CANADA CITY LAT LONG Lc BANFF 51 -115 1 BURNABY 49 -122 0 CALGARY 51 -114 1 CAPE - DORSET 64 -76 0 CHICOUTIMI 48 -71 0 DAWSON 64 -139 1 EASTMAIN 52 -78 0 EDMONTON 53 -113 1 FORT SEVERN 56 -87 1 HALIFAX 44 -63 0 IGALUIT 63 -68 0 INUKJUAK 58 -78 0 KITCHENER 43 -80 0 LONDON 42 -81 0 MISTASSINI 50 -73 0 MONTREAL 45 -73 0 OSHAWA 43 -78 0 OTTAWA 45 -75 0 QUEBEC 46 -71 0 REGINA 50 -104 1 RICHMOND 49 -123 0 SASKATOON 52 -106 1 SEPT-ILES 50 -66 -1 SHERBROOKE 45 -71 0 ST. ANTHONY 51 -55 0 SAINT JOHN (NB) 45 -66 0 ST. JOHN'S (NFLD) 47 -52 0 SUDBURY 46 -81 0 THUNDER BAY 48 -89 1 TORONTO 43 -79 0 TROIS-RIVIERES 46 -72 0 URANIUM CITY 59 -108 0 VANCOUVER 49 -123 0 WINDSOR 42 -83 1 WINNIPEG 49 -97 0 USA CITY LAT LONG Lc ABILENE 32 -99 1 ALBUQUERQUE 35 -106 0 ALLENTOWN 40 -75 0 AMARILLO 35 -101 1 ANCHORAGE 61 -149 1 ATLANTA 33 -84 1 AUSTIN 30 -97 0 BAKERSFIELD 35 -119 0 BALTIMORE 39 -76 0 BATON ROUGE 30 -91 0 BEAUMONT 30 -94 0 BILLINGS 45 -108 0 BIRMINGHAM 33 -86 0 BOISE 43 -116 1 BOISE CITY 36 -102 1 BOSTON 42 -71 0 BROWNSVILLE 25 -97 0 BUFFALO 42 -78 0 CEDAR RAPIDS 41 -91 0 CHARLOTTE 35 -80 0 CHATTANOOGA 35 -85 1 CHEYENNE 41 -104 0 CHICAGO 41 -87 0 CINCINNATI 39 -84 1 CLEVELAND 41 -81 0 COLOMBUS 39 -82 0 COLORADO SPRINGS 38 -104 0 CORPUS CHRISTI 27 -97 0 DALLAS 32 -96 0 DENVER 39 -104 0 DES MOINES 41 -93 0 DETROIT 42 -83 1 DULUTH 46 -92 0 EL PASO 31 -106 0 ERIE 42 -80 0 EUGENE 44 -123 0 EVANSVILLE 37 -87 0 FLINT 43 -83 1 FORT LAUDERDALE 26 -80 0 FORT WAYNE 41 -85 1 FRESNO 36 -119 0 GRAND RAPIDS 42 -85 1 GREAT FALLS 47 -111 0 GREENSBORO 36 -79 0 HAMPTON 37 -76 0 HARTFORD 41 -72 0 HONOLULU 21 -157 0 HOUSTON 29 -95 0 HUNTSVILLE 34 -86 0 INDIANAPOLIS 39 -86 1 JACKSON 32 -90 0 JA...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории