|
Фрагмент инструкции
In the event of a power outage the pump will be powered by the battery. Once line power is restored, the charger will recharge the battery. If there is a failure of the primary pump, the charger will supply power to the pump through the battery if line power is present; otherwise, the battery will take over until the problem has been corrected. The lights on the front panel of the charger indicate the state of system: The red light: Indicates that AC line power is present. The green light: Indicates that the battery is charged to 12V DC*. During periods of extended power outage the charge on the battery may drop below 12V DC which would cause the green light to go out. This is normal. The green light will be illuminated once the charger restores the voltage level to 12V DC. The yellow light: Indicates that the battery is charged above 8V DC. If the yellow light is not illuminated, it indicates that the charge on the battery is below 8V DC. If the line power is out, the pump may have depleted the battery due to normal operation. If there has been no power outage and the primary pump is working properly, it may indicate that the battery is defective or that the controller is defective. Refer to the Troubleshooting guide on page 8 for further instructions. If the Green and Yellow lights flash intermittently, refer to Section G in the Trouble Shooting Guide on page 8. *Voltage is only one indicator of the state of the battery, and does not reflect the true condition of the battery. Use a hydrometer to more accurately determine the condition of the battery. Operation of the Audible Alarm (All Models) All Aquanot® pump systems are equipped with an alarm which sounds when the pump is activated. The alarm will automatically silence when the pumping cycle is completed. Activation of the audible alarm indicates that the primary pump has failed or line power to the primary pump is not present. Whenever the alarm is activated the primary pump and outlet should be inspected. The On/Off switch, located on the side of the alarm enclosure, allows the audible alarm to be turned off, however, this practice is not recommended. Verify that the alarm switch is in the “on” position, by manually turning the pump “on”. The Aquanot® Battery There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality. A defective battery will never become fully charged and may damage the circuits of the charger. It is for this reason that Zoeller offers its own line of batteries. We offer both a Water/Acid Deep-Cycle Battery which can run the pump continuously for over 7. hours, and an AGM battery, which will power the pump for over 3. hours. These times are based on continuous pumping at 10’ of static head. Actual times will vary depending on static head, volume of water entering the pit, and the condition of the battery. Follow these recommendations: • Use a B.C.I. size 27 deep-cycle battery, 175 minute reserve capacity, or larger. • Do NOT use a “maintenance-free” battery unless it is Gel-filled or AGM battery. • Replace your battery every 3 years. • Do not let corrosion build up on the battery terminals. • Do not place your battery on a concrete floor where it will discharge faster. • To check specific gravity, follow the instructions on a hydrometer (not applicable for Gel or AGM batteries). PROTECT YOUR WARRANTY: • Water level in batteries must be checked once a month (not applicable for Gel or AGM batteries). © Copyright 2009 Zoeller Co. All rights reserved. 6 7 © Copyright 2009 Zoeller Co. All rights reserved. Before servicing a pump, always shut off the main pow er breaker and then unplug the pump - making sure you are not stand ing in water and are wearing in su lat ed pro tec tive sole shoes. Un der fl ooded con di tions, con tact your local elec tric company or a qualifi ed licensed electrician for dis con nect ing electrical service prior to pump re mov al. If the following checklist does not solve the prob lem, con sult Zoeller’s Technical Service De part ment 1-(800) 928-7867 - Do not at tempt to service or oth er wise dis as sem ble pump. SK1786 REF. NO. MOD ELS: 580-A 580-B 580-C 580-D 580-E 585-A 585-B 585-C 585-D 585-E 585-F 585-G DESCRIPTION QTY 1 Motor Brushes 2 011882 011882 011882 013878 *Consult Factory 011882 011882 011882 011882 013878 *Consult Factory *Consult Factory 2 Pump Alarm 1 012485 012485 012485 012485 012485 012485 012485 012485 012485 012485 012485 012485 3 Pump Switch 1 011990 011990 017205 017205 017205 011990 011990 011990 017205 017205 017205 017205 4 Float Kit & Cable 1 012109 012109 012709 012709 012709 012109 012109 012109 012709 012709 012709 012709 5 Lead Wires 1 012401 012401 012401 012401 012401 012401 012401 012401 012401 012401 012401 012401 6 Terminal Spade 1 004442 004442 004442 004442 004442 004442 004442 004442 004442 004442 004442 004442 7 Terminal Ring 1 011939 011939 011939 011939 011939 011939 011939 011939 011939 011939 011939 011939 8 Pump Mot...
Эта инструкция также подходит к моделям:Сантехника - AQUANOT 585 (459.59 kb)