Фрагмент инструкции


Wall anchors used must have a minimum pull-out rating of 1,000lbs. Product warranties may be foundunder "Product Information" on our web site at Installation Instructions OBSOLETE SS-3/AST/WH97TAS Express® LavatorySystem SS-Series *Complies with Texas Accessibility Standards (TAS) for Juvenile Height applications. Table of Contents Pre-Installation Information . . . . . . . . . . . . . . . .2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 Installation Instructions . . . . . . . . . . . . . . . .5-11 Cleaning and Maintenance . . . . . . . . . . . . . . . .12Soap Dispenser Maintenance . . . . . . . . . . .13-14 Check Valve Troubleshooting . . . . . . . . . . . . . .14Assembly of Components . . . . . . . . . . . . . .15-16Metering Air Valve Maintenance . . . . . . . . . . .17Metering Air Valve Troubleshooting . . . . . .17-18Vernatherm™ Thermostatic Mixing Valve . . . .19 215-1240 Rev. E; EN 08-805 P.O. Box 309, Menomonee Falls, WI 53052-0309 © 2008 Bradley Corporation TEL. 1-800-BRADLEY FAX 262-251-5817 Page 1 of 19 4/24/08 Express® Lavatory System SS-Series SS-3/AST/WH97TAS Installation - Obsolete Pre-Installation Information Texas Accessibility Standards compliant: The SS-3/AST/WH97TAS Express® Lavatory System meets Texas Accessibility standards (TAS) for barrier-free clearances, reaches and controls. Always check local codes and ordinances for compliance. Pushbutton and air valve Each sprayhead is controlled by a pushbutton air valve, enabling each user to activate a single flow of water. Air valves use 0.5 gpm for a ten-second duration, meeting the ANSI/ASHRAE/IES 90A-1980 Standard. Supplies required for installation: • (10) 3/8" wall anchors, bolts and washers to mount frame and bowl to wall (minimum pull-out rating of 1,000 lbs.) • 1/2" NPT hot and cold supply piping • 1-1/2" NPT drain piping 4/24/08 Bradley Corporation • 215-1240 Rev. E; EN 08-805 Express® Lavatory System SS-Series Installation - Obsolete SS-3/AST/WH97TAS SS-3/AST/WH97TAS Express® Lavatory System Dimensions Dimensions continue . . . Bradley Corporation • 215-1240 Rev. E; EN 08-805 4/24/08 Express® Lavatory System SS-Series SS-3/AST/WH97TAS Installation - Obsolete Dimensions continued . . . Juvenile Height SS-3/AST/WH97TAS Grades Pre-K thru 5 or 6 Juvenile Height SS-3/AST/WH97TAS Grades 6 thru 8 or 9 4/24/08 Bradley Corporation • 215-1240 Rev. E; EN 08-805 Express® Lavatory System SS-Series Installation - Obsolete SS-3/AST/WH97TAS Installation Instructions Step 1: Rough in Note: See Figure 1a (below) and Figures 1b and 2 (on page 6) when roughing in the Express®. IMPORTANT: Flush the supply lines before making connections. Debris in supply lines will cause the valves to malfunction. IMPORTANT: Dimensions shown in Figure 1a are for Juvenile Height grades Pre-K thru 5 or 6, and in Figure 1b for Juvenile Height grades 6 thru 8 or 9. 1. Rough in 1/2" NPT hot and cold supply lines through wall at dimensions shown. 2. Rough in 1-1/2" NPT drain waste connection through wall at dimensions shown. 3. Install (10) 3/8" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by installer) at the locations shown in Figures 1a and 1b. NOTE: The anchors will be used to mount the Express® bowl and frame to the wall. SS-3/AST/WH97 Express® Lavatory System Dimensions Juvenile Height Mounting (Grades Pre-K thru 5 or 6) Figure 1a Installation Instructions continue . . . Bradley Corporation • 215-1240 Rev. E; EN 08-805 4/24/08 Express® Lavatory System SS-Series SS-3/AST/WH97TAS Installation - Obsolete SS-3/AST/WH97 Express® Lavatory System Dimensions Juvenile Height Mounting (Grades 6 thru 8 or 9) Figure 1b Figure 2 Installation Instructions continue . . . 4/24/08 Bradley Corporation • 215-1240 Rev. E; EN 08-805 Express® Lavatory System SS-Series Installation - Obsolete SS-3/AST/WH97TAS Installation Instructions continued . . . Step 2: Mount frame to wall 1. Remove the nine Torx-head screws securing the panel to the frame, and remove the panel (see Figure 3). 2. Position the frame against the wall, ensuring that it is level. IMPORTANT: Anchoring the frame to a wall that is not flat may cause the frame tobend. If necessary, install shims to compensate for wall distortion. 3. Ensure that the back of the frame is flat against the wall. If wall is not flat, insert shims behind the frame to ensure that it will not bend when anchored. 4. Once you have positioned the frame such that it is level and flat against the wall or shimmed, use the 3/8" bolts and washers to mount the frame to the wall (see Figure 4). Figure 3 (9) TORX-HEAD SCREW FRAME PANEL FRAME 3/8" BOLTS AND WASHERS Figure 4 Installation Instructions continue . . . Bradley Corporation • 215-1240 Rev. E; EN 08-805 4/24/08 7 Figure 5 Express® Lavatory System SS-Series SS-3/AST/WH97TAS Installation - Obsolete Installation Instructions continued . . . Step 3: Install bowl assembly IMPORTANT: Moving and positioning the bowl wil...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории