Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Southern Pride, модель XLR-600-SL

Производитель: Southern Pride
Размер: 191.69 kb
Название файла: xlr_600spec_2-04.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Steel or 12 gauge Stainless Steel. Exterior: 22-gauge Polished Stainless Steel Firebox: 14” Diameter 1/4” thick H.R. pipe. 1/4” thick firebox door. Uses wood logs or charcoal. Capacity: 3-4 logs 4”-6” dia. 12-16” long. Dimensions: 76” tall, 47” wide, 87 3/8” deep (including covers) w/ 15” legs Shell Dimensions: 61” tall, 33” wide, 79 3/8” long. Food Racks: Rotisserie with four (4) hanger racks, each with three (3) 18”x 22” food racks (12 Total). Thirty Three (33) Sq.Ft. of Cooking Surface. 4 11/16” Spacing between food racks. Air Circulation: Low Velocity Convection Fan. Temperature Range: 100-325 degrees F. Burner: Electronic Pilot Gas Burner (Specify Natural or L.P. gas.) Approvals: UL, ULC, NSF Venting: See back page for venting instructions. COOKING CAPACITIES FOR THE XLR-600 Pork Butt (7 lb.) 108 pieces 756 lb. total St. Louis Ribs (2.75lb.) 48 pieces 132 lb. total w/Optional Rib Racks 120 pieces 330 lb total Chicken (3lb.) 144 pieces 432 lb. total Brisket (12 lb.) 54 pieces 648 lb. total Spare Ribs (3.5lb.) 36 pieces 126 lb. total 12 1/2" 6” Flue 10” Flue 16 1/2" 47" NOTE: Drawings Show the Optional Smoke Extractor on SLSE Models. Optional Smoke Extractor Optional Smoke Extractor NOTE: Dimensions Show position of the 10” flue on the optional smoke extractor on the -SLSE Model. 8" 5 1/2" Electrical Connection for VSP Hood 51/ 2" Electrical Connection for VSP Hood XLR-600-SL VENTING INSTALLATION VSP HOOD SYSTEM: Purchased through Southern Pride VSP HOODS are U/L Listed to the applicable Southern Pride oven models and are NSF Certified. HOOD SYSTEM TO INCLUDE: 1. Ventilation Hood 2. Two speed fan (1380/2000) 3. Curb with vented extension and hinge kit (Specify roof pitch) 4. Grease capture trough 5. Combustion chamber flue vent SUPPLIED BY CUSTOMER: 6. Duct from hood to fan NOTE: If you have a duct longer than 10 feet or an elbow in your duct your installation, it may require a larger capacity exhaust fan. Please specify your duct requirements when ordering the VSP Hood System. XLR-600-SL with recommended optional VSP Vent Hood System. 1 2 3 SPECIFY ROOF PITCH WHEN ORDERING 4 5 6 ALL MODELS MAY ALSO BE INSTALLED UNDER A CANOPY HOOD RATED FOR COMMERCIAL COOKING APPLIANCES. NOTE: THE SIX INCH ALLFUELCHIMNEY SHOULD EXTEND AT LEAST3’ ABOVE THE THROUGH THE WALL HIGHESTSIDE OF THE ROOF OPENING RAIN AND BE ATLEAST2’ HIGHER THAN ANY CAP DIRECT VENT INSTALLATION 10 ” ALL FUEL SMOKE EXTR ACTOR CH IMNEY HORIZON TAL. 6” ALL FUEL CHIMNEY EXHAUS T FAN NOTE: THE 10 ” ALL FUEL SMOKE EX- TRACTOR CHIMNEY TERMIN ATES AT THE ROOF C URB NOTE 1. When installing an Oven through a wall constructed of combustible material, use the Southern Pride Insulation Kit between the oven and the wall. 2. The room that the face of the oven is installed into should have a balanced or positive air pressure. If the room has negative air pressure, smoke could escape into the room during operation. SUPPLIED BY SOUTHERN PRIDE: (*) Smoke Extractor Damper with 10” chimney adapter plate SUPPLIED BY CUSTOMER: 6” All Fuel Chimney, 6” Rain Cap, and all accessories necessary for installation of the 6” chimney. 10” All Fuel Chimney, Exhaust Fan (NOTE: Fan must be listed for use as a commercial kitchen ventilator), fan curb, and all accessories necessary for installation of the smoke extractor system. The oven’s minimum clearances from combustible materials are 18" on left side, 24" on right, 18" on top, 48" from front, and 2" on back. Minimum clearances 18" to chimney connector and to smoke extractor chimney connector. Floor may be constructed of a combustible material. (Note: minimum clearance dimensions are from the oven cabinet, not from component cover.) (If provision is made for access to service, minimum clearance can be reduced to 2" on left side.) May be installed through wall with zero clearance with BBR kit No. 2099. ANY VENTILATION SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES. CONSULT WITH LOCAL OFFICIALS AND A COMMERCIAL KITCHEN VENTILATION CONTRACTOR PRIOR TO INSTALLATION. Southern Pride Distributing, L.L.C. Phone: 618-997-9348 2102 East Main Street - Marion, Illinois 62959 Fax: 618-993-5960 sales@sopride.com service@sopride.com parts@sopride.com Sales: 800-851-8180 Service: 800-437-2679 Service Fax: 618-993-0378 9/1/04 ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории