Производитель: Transition Networks
Размер: 101.43 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Refer to FAULT ISOLATION and CORRECTION SWITCH SET #4 UP) for RIGHT SWITCH SET to have any effect. If E1 is selected ( LEFT SWITCH SET #4 DOWN), RIGHT SWITCH SET is ignored and the default is E1 selected ( LEFT SWITCH SET #3 UP, #4 UP), but RIGHT SWITCH SET is not set to a valid short default is DSX-1 0’ -133’ cable. selected ( LEFT SWITCH SET #3 DOWN, #4 UP), but RIGHT Transmit All Ones onto TP on loss of FiberCarrier Detect UP= Enabled T1/E1 Selection UP= T1 Long Haul/Short Haul (T1 only) UP= Short Haul Transmit All Ones onto Fiber on loss of TP Carrier Detect UP= Enabled 1 2 3 4 NETWORK Switch Settings KEY = UP = DOWN 1 2 3 4 1 2 3 4 toward network connectorstoward chassis LEFT SWITCH SET NOTE: T1 must be selected ( LEFT 3.0V 120. cable. If T1 and short haul are haul value, the short haul If T1 and long haul are SWITCH SET is not set to a valid long haul value, the long haul default is 0db 100. cable. If the media converter fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action: 1. Is the P(o)W(e)R LED on the media converter illuminated? NO • Is the power adapter the proper voltage and cycle frequency for the AC outlet? NOTE: Refer to the “ Power Supply Requirements” on page 7. • Is the power adapter properly installed in the media converter and in the outlet? • Contact Technical Support: (800) 260-1312/(800) LAN-WANS. YES • Proceed to step 2. 2. Is the SDF (Signal Detect/Fiber) LED illuminated? NO • Check fiber cables for proper connection. • Verify that TX and RX cables on media converter are connected to RX and TX ports, respectively, on other media converter. • Contact Technical Support: (800) 260-1312/(800) LAN-WANS. YES • Proceed to step 3. 3. Is the SDC (Signal Detect/Copper) LED illuminated? NO • Check twisted pair cables for proper connection. • Check RJ-45 Pinning Switch for correct twisted pair cable configuration. • Check integrity of device attached to media converter pair cable. • Contact Technical Support: (800) 260-1312/(800) YES • Contact Technical Support: (800) 260-1312/(1 2 3 4 toward network connectors SHORT HAUL Switch Settings* RIGHT SWITCH SET 1 2 3 4 1 2 3 4 toward chassis LONG HAUL Switch Settings* 1 2 3 4 DSX-1 533'-655' 100 ohm cable DSX-1 399’ -533’ 100 ohm cable DSX-1 266’ -399’ 100 ohm cable DSX-1 133'-266' 100 ohm cable DSX-1 1 0’ -133’ and ANSI T1.403 100 ohm cable DSX-1 6.0V 100 ohm cable -22.5db 100 ohm cable -15db 100 ohm cable -7.5db 100 ohm cable 0db 100 ohm cable *Right *Right INSTALLATION (continued) Install Cable COPPER T1 100 OHM (RJ-45 CONNECTOR) 1. Locate or build twisted-pair cables that are compliant with specifications on page 10, with RJ-45 plug connectors at both ends. 2. Ensure that MDI/MDI-X switch is set according to network conditions. 3. Connect RJ-45 plug connector at one end of cable to media converter RJ-45 jack connector. 4. Connect RJ-45 plug connector at other end of cable to network equipment. FIBER 1. Locate ...

Эта инструкция также подходит к моделям:
Ресиверы и усилители - SSDTF1011-100 (101.43 kb)
Ресиверы и усилители - SSDTF1014-100 (101.43 kb)
Ресиверы и усилители - SSDTF1012-100 (101.43 kb)
Ресиверы и усилители - SSDTF1013-100 (101.43 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории