Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Adder Technology, модель Cable Box

Производитель: Adder Technology
Размер: 89.22 kb
Название файла: c61b959e-f4eb-48bf-a99c-360fdea6178c.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Also, Adder will not be for any loss, damage or indirectly from the use of this product. Adder’s total liability under circumstances be limited to the replacement value of this product. Regulatory information European EMC directive 89/336/EEC This equipment has been tested and found to comply with accordance with the specifications in the European standard EN55022. These limits are designed to provide reasonable protection against harmful interference. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television reception. However, there is no guarantee that harmful interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to correct the interference with one or more of the following measures: (a) Reorient or relocate the receiving antenna. (b) Increase the separation between the equipment and the receiver. (c) Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. (d) Consult the supplier or an experienced radio/TV technician FCC statement This equipment generates, uses and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device in accordance with specifications in Subpart J of part 15 of FCC rules, which are designed to provide reasonable protection such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area may cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference. Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. Adder Technology Limited, Adder Corporation, Email: support@adder.com Technology House, 29 Water Street, Web: Trafalgar Way, Newburyport, Cambridge, CB3 8SQ, MA 01950, United Kingdom United States of America Tel: +44 (0)1954 780044 Tel: +1-888-932-3337 Fax: +44 (0)1954 780081 Fax: +1-888-275-1117 © 2003 Adder Technology Limited • Release 1.0b • December 2003 • Part No. ADD0052/1 All trademarks are acknowledged. Sun ® Converter User Guide Your Sun converter cable package In addition to this brief guide, your package should Sun converter cable KVM Switch end Keyboard, video and mouse connectors Computer end Video and keyboard & mouse connectors Circuitry shell This moulding contains Sun combined keyboard & mouse connector all of the signal conversion circuitry Connecting Sun ® converter cable Your converter cable is primarily Keyboard, Video and Mouse Note: It is technically monitor directly to the converter you would first need to gender changers for the PS/video connector. To connect your Sun converter cable 1 If possible, switch off your computer(s) and KVM switch. 2 At the end of the converter cable that has three plugs, connect the keyboard, mouse and video plugs to the relevant sockets on your KVM switch. KVM switch Mouse and Keyboard connectors Video connector Sun computer Video connector Keyboard & mouse connector 3 At the other end of the converter cable (with two plugs), connect the video and Sun keyboard & mouse plugs to the relevant sockets on your computer. 4 Switch on your computer(s) and KVM switch, and operate in the usual manner. Note: If you are using your Sun converter cable inconjunction with an Adder MP-type KVM switch no further action is required to ensure correct operation. However, with other Adder switches or non-Adder switches, you need to instruct your Sun converter cable to declare a valid keyboard country code to the system. Further details about this feature are provided in the upgrade notes available from Your Sun converter cable emulates the presence of a keyboard and mouse to the computer at all times. This means that there will be no delay in response when switching to this channel. Connector/icons & Monitor (video) Dark blue Keyboard Purple Mouse or Mid green Important information • For use in dry, oil free indoor environments only. • Your Sun converter cable contains no user-serviceable parts. • For connection only to Sun computer systems and KVM switch connectors. Software upgrades, country codes & keypresses Your Sun converter cable can be upgraded to take advantage improvements and operation changes that may become available in the future. Additionally, it can also be made to declare a particular keyboard country code when used with legacy KVM switches. The necessary upgrade and keyboard files are made available within the Support section of the...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории