Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Omega Vehicle Security, модель PTC900

Производитель: Omega Vehicle Security
Размер: 1.35 mb
Название файла: M4494.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


The meter configuration data can be saved to a file for later recall. Once the meters have been initially configured, the parameter list may be locked out from further modification entirely, or the setpoint, timer start/stop values, counter start/stop values, RTC time SET, and Display Intensity can be made accessible. This lockout is possible through a security code or user input. The meters have been specifically designed for harsh industrial environments. With a NEMA 4X/IP65 sealed bezel and extensive testing to meet CE requirements, the meter provides a tough yet reliable application solution. SAFETY SUMMARY All safety related regulations, local codes and instructions that appear in this literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Do not use this unit to directly command motors, valves, or other actuators not equipped with safeguards. To do so can be potentially harmful to persons or equipment in the event of a fault to the unit. CAUTION: Risk of Danger. Read complete instructions prior to installation and operation of the unit. CAUTION: Risk of electric shock. DIMENSIONS In inches (mm) Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.1" (53.4) H x 5" (127) W. C US LISTED UL R IND. CONT. EQ. 51EB TABLE OF CONTENTS General Meter Specifications. . . . . . . . . . . . . 4 Optional Plug-In Cards and Accessories . . . . 5 Installing the Meter . . . . . . . . . . . . . . . . . . . . 6 Setting the Jumpers . . . . . . . . . . . . . . . . . . . 6 Installing Plug-In Cards. . . . . . . . . . . . . . . . . 7 Wiring the Meter. . . . . . . . . . . . . . . . . . . . . . 7 Reviewing the Front Buttons and Display . . 10 Programming the Meter. . . . . . . . . . . . . . . . 11 Factory Service Operations. . . . . . . . . . . . . 26 Programming Overview. . . . . . . . . . . . . . . . 29 GENERAL METER SPECIFICATIONS 1. DISPLAY: 6 digit, 0.56" (14.2 mm) red sunlight readable or standard green LED 2. POWER: AC Versions (PTC901, PTC900): AC Power: 85 to 250 VAC, 50/60 Hz, 18 VA Isolation: 2300 Vrms for 1 min. to all inputs and outputs. (300 V working) DC Versions (PTC901-LV, PTC900-LV): DC Power: 11 to 36 VDC, 14 W (Derate operating temperature to 40°C if operating <15 VDC and three Plug-in cards are installed) AC Power: 24 VAC, ± 10%, 50/60 Hz, 15 VA Isolation: 500 Vrms for 1 min. to all inputs and outputs (50 V working) 3. SENSOR POWER: 12 VDC, ±10%, 100 mA max. Short circuit protected. 4. ANNUNCIATORS: TMR -Timer Display SP1 -Setpoint 1 Output CNT -Cycle Counter Display SP2 -Setpoint 2 Output DAT -Real-Time Clock Date Display SP3 -Setpoint 3 Output -Real-Time Clock Time Display SP4 -Setpoint 4 Output 5. KEYPAD: 3 programmable function keys, 5 keys total. 6. TIMER DISPLAY: Timer Range: 23 Selectable Ranges Timing Accuracy: ± 0.01% Minimum Digit Resolution: 0.001 Sec. Maximum Least Significant Digit Resolution: 1 Hr. Maximum Display: 999999 7. CYCLE COUNTER DISPLAY: Counter Range: 0 to 999999 Digit Resolution: 1 cycle Maximum Count Rate: 50 Hz 8. REAL-TIME/DATE DISPLAY (PTC901): Real-Time Display: 5 display formats Hr/Min/Sec (12 or 24 Hr. format); Hr/Min (24 Hr.); Hr/Min (12 Hr. with or without AM/PM indication) Date Display: 7 display formats Month/Day or Day/Month (numeric or 3-letter Month format); Month/Day/Year or Day/Month/Year (all numeric); Day of Week/Day (3-letter Day of Week format) 9. REAL-TIME CLOCK CARD: Field replaceable plug-in card Time Accuracy: ± 5 secs./Month (1 min./year) with end-user calibration Battery: Lithium 2025 coin cell Battery Life Expectancy: 10 yrs. typical Synchronization Interface: Two-wire multi-drop network (RS485 hardware), 32 units max., operates up to 4000 ft. Isolation To Timer & User Input Commons: 500 Vrms for 1 min. Working Voltage: 50 V. Not isolated from all other commons. 10. TIMER INPUTS A and B: Logic inputs configurable as Current Sinking (active low) or Current Sourcing (active high) via a single plug jumper. Current Sinking (active low): VIL = 0.9 V max., 22K. pull-up to +12 VDC. Current Sourcing (active high): VIH = 3.6 V min., 22K. pull-down, Max. Continuous Input: 30 VDC. Timer Input Pulse Width: 1 msec min. Timer Start/Stop Response Time: 1 msec max. Filter: Software filtering provided for switch contact debounce. Filter enabled or disabled through programming. If enabled, filter results in 50 msec start/stop response time for successive pulses on the same input terminal. 11. USER INPUTS: Three programmable user inputs Logic inputs configurable as Current Sinking (active low) or Current Sourcing (active high) through a single plug jumper. Current Sinking (active low): VIL = 0.9 V max., 22K. pull-up to +12 VDC. Current Sourcing (active high): VIH = 3.6 V min., 22K. pull-down, Max. Continuous Input: 30 VDC. ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории