Войти:
Оценок - 4, средний балл: 4.5 ( )

Инструкция по эксплуатации Campbell Hausfeld, модель PS120B

Производитель: Campbell Hausfeld
Размер: 7.58 mb
Название файла: 76a00f39-342e-4809-8a36-a5a0ff44c6c9.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


hOw TO ChANGE SPrAy TIPS It may be necessary to change spray tips during a paint job. Follow these steps for safe, easy tip changes. 1. Depressurize and turn off unit per manufacturer’s instructions. 2. Engage gun trigger lock. 3. Pull red tip insert out of spray base and replace with different tip, fully inserting tip into base. hOw TO ATTACh rOllEr ACCESSOry 1. Depressurize and turn off unit per manufacturer’s instructions. 2. Engage gun trigger lock. 3. Remove spray base, tip, seal and washer assembly. 4. Attach roller accessory (AL2275 shown) to airless spray gun. If needed use thread adapter and washer between roller and spray gun as shown. Figure - Attach roller accessory to spray gun 9 Cleanup cleanup fo r OVERNIGHT STORAGE NOTE: Cleaning and maintenance of the pump are the most important steps you can take to ensure proper operation and a long life for your airless paint sprayer. Please follow the cleaning instructions carefully and . . . WEAR ALL NECESSARY SAFETY GEAR Necessa ry Too ls / Mate ria ls: • One (1) bucket • Water • Plastic wrap W hen reusing the sprayer with the same paint the next day at the same job site, it is not necessary to flush the paint from the system. However, it is important to keep air from coming into conta ct with the paint. NOTE: Do NOT disconnect any hoses. 1. Turn prime/spray control to PRIME position. High pressure hose may still be pressurized with prime/spray control in the PRIME position. With the gun pointed in a safe direction, pull the gun trigger to relieve any pressure in the hose. 2. Engage gun trigger lock. 3. Place spray gun in bucket of water. There should be enough water to cover spray tip. This will prevent paint from drying or clogging tip. 4. Leave suction and bypass tubes in bucket of paint. Make sure ends of suction and bypass tubes are below surface of paint in bucket. 5. Cover bucket and tubes with plastic wrap or a damp towel to prevent film forming on paint. Or, if using latex paint, pour a very thin layer of water over top of paint. Stir water into paint the next morning. Airless Paint Sprayers Operating Instructions and Assembly Instructions Turn Prime/Spray Control to PRIME Position 1 3 Place Gun in Water Latex Paint: Use Thin Layer of Water to Cover Paint 5 Engage Trigger Lock Cover Bucket 2 Suction and Bypass Tubes Remain in Bucket with Ends Below Paint Surface 4 or PAINT PAINT 10 Temporary Cleanup To Lock Locked Water 11 Operating Instructions and Assembly Instructions Airless Paint Sprayers Cleanup fo r Changing Paints or Tempo rary Sto rage fo r Mo re Than One Nig ht WEAR ALL NECESSARY SAFETY GEAR Necessa ry Too ls / Mate ria ls: • Rag • Gloves • Two (2) buckets • At least one (1) gallon of cleaning fluid (water or mineral spirits depending on coating type) • C leaning brush NOTE: Do NOT disconnect any hoses. 1. Turn prime/spray control to PRIME position. 2. Turn power switch to ON. High pressure hose may still be pressurized with prime/spray control in the PRIME position. With the gun pointed in a safe direction, pull the gun trigger to relieve any pressure in the hose. 3. Turn pressure to HIGH (completely clockwise). 4. Lift suction assembly above fluid level in bucket. While holding suction assembly above paint level, allow pump to run until empty. 5. Immediately place both suction assembly and bypass tube in a bucket containing enough cleaning fluid to cover suction filter by two inches. Allow pump to prime and begin circulating fluid. 6. While fluid is circulating, soak rag in fluid and wipe exterior of suction assembly and bypass tube. Remove suction filter. Wipe suction filter with rag removing excess paint buildup. Reinsert filter into suction tube. Cleaning Pump Turn Pressure to HIGH (completely clockwise) 3 4 Lift Suction Assembly above Paint Level in Bucket Turn Prime/Spray Control to PRIME Position 1 6 Wipe Exterior of Suction Assembly and Bypass Tube Suction Assembly and Bypass Tube in Bucket of cleaning fluid 2 Turn power switch to ON (shown in the OFF position) 5 Airless Paint Sprayers Operating Instructions and Assembly Instructions Cleaning Hose and Gun Turn Prime/ Spray Control to SPRAY (knob is horizontal) If Reversible Tip is Used, Rotate Spray Tip to CLEAN Position. While Pulling Trigger, Direct Fluid Stream Along Inside of Bucket 9 10 Cleanup fo r Changing Paints or Tempo rary Sto rage fo r Mo re Than One Nig ht (Continued) Allow the cleaning fluid to continue circulating for approximately 10 minutes. 7. Turn pressure to HIGH (completely clockwise). 8. Turn prime/spray control to SPRAY position. 9. Rotate spray tip to CLEAN position. 10. Point spray gun into bucket of paint and pull trigger. NOTE: To reduce splashing, direct fluid stream along inside of bucket and above the paint level. 11. As soon as cleaning fluid is flowing from spray gun, release trigger. NOTE: It should take less than one minute to clear each 25 feet of high pressure hose. 12. Engag...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории