Войти:
Оценок - 15, средний балл: 4.3 ( )

Инструкция по эксплуатации Oregon Scientific, модель RRM902

Производитель: Oregon Scientific
Размер: 2.86 mb
Название файла: 9fdce2b4-5219-4487-950f-61fa5c211b00.pdf
Язык инструкции:svitenesfrdenlpt
Перейти к скачиванию



Фрагмент инструкции


: daily alarm is on 12. VOL: volume level is displayed 1 2 3 4 5 6 7 8 BACK VIEW 89 123 9 10 11 12 10 4 567 11 12 13 14 1. : activate / deactivate alarm function; set alarm; view alarm status (when radio is on) 2. : toggle station number (when radio is on); save radio frequency 3. : turn radio on / off 4. TUNE +/-: auto search / adjust radio frequency 5. °C / °F: user selectable temperature units 1. SNOOZE · SOUND: activate snooze alarm; turn soothing sound on / off; select soothing sound 2. : clock signal reception indicator 3. ZONE: time zone offset 4. : external audio device successfully connected 5. : radio is on 6. : soothing sound is on 7. : radio station selected (user can set up to 8 stations); soothing sound selected for alarm option 8. Name of soothing sound selected is displayed 9. OFF Zz: sleep function enabled (ZZ) / disabled (OFF ZZ) 2 EN 6. DIMMER: select display brightness 7. COLOUR (OFF·PROGRAM·LOOP): activate / deactivate color-changing light show; select pre- programmed (sound specific) light show or rainbow loop effect 8. : set clock 9. ZZ: activate sleep timer; adjust timer settings (120, 90, 60, 30, 15, 0) 10. VOL+ / VOL-: increase / decrease value of the setting; increase / decrease volume 11. RESET: reset unit to default settings 12. SEARCH: initiate sensor search 13. PAUSE: select a specific color lighting; restart color- changing effect 14. Socket for audio line-in BOTTOM VIEW 1. Adapter socket 2. Battery compartment 12 REMOTE SENSOR 2 1 4 3 5 1. LED status indicator 2. Wall mount hole 3. Battery compartment 4. RESET hole: reset unit to default settings 5. CHANNEL switch: select Channel 1 GETTING STARTED POWER SUPPLY Adapter The adapter powers the unit. Plug adapter into socket, making sure the adapter is not obstructed and is easily accessible to the unit. To completely disconnect from power, the adapter should be disconnected from the main unit. 3 EN NOTE The main unit and adapter should not be exposed to wet conditions. No objects filled with liquid, such as vases, should be placed on the main unit and adapter. 1 x CR2032 battery for memory back-up To insert batteries: 1. Remove the battery compartment cover. 2. Insert the battery, matching the polarities. 3. Press RESET after each battery change. LOCATION MEANING Clock area Main unit batteries low Outdoor temperature Sensor batteries low area TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results. NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing. REMOTE SENSOR SENSOR DATA TRANSMISSION To set up the remote sensor: Outdoor sensor: 1. Slide open the battery compartment. The sensor reception icon in the remote sensor area shows the status: 2. Slide channel switch to select channel 1. 3. Insert the battery, matching the polarities. 4. Press RESET after each battery change. 5. Close the battery compartment. 6. Press and hold SEARCH on main unit to initiate search and start receiving time and temperature data from the sensor. 7. Place the sensor within 30 m (98 ft) of the main unit ICON DESCRIPTION Main unit is searching for sensor(s) A channel has been found The sensor cannot be found using the table stand or wall mount. 4 EN NOTE If the sensor is not found, check the batteries, obstructions and remote unit location. Press and hold SEARCH to force another sensor search. For best results: • Place the sensor out of direct sunlight and moisture. • Position the sensor so that it faces the main unit, minimizing obstructions such as doors, walls and furniture. • Place the sensor in a location with a clear view to the sky, away from metallic / electronic objects. • Position the sensor close to the main unit during cold winter months as below-freezing temperatures may affect battery performance and signal transmission. TIP Ideal placements for the sensor would be in any location on the exterior of the home at a height of not more than 1.5m (5 ft) and which can shield it from direct sunlight or wet conditions for an accurate reading. CLOCK CLOCK RECEPTION This product is designed to synchronize its clock automatically with a clock signal. RRM902: EU: DCF-77 signal: within 1500km (932 miles) of Frankfurt, Germany. RRM902U: UK: MSF-60 signal: within 1500km (932 miles) of Anthorn, England. RRM902A: US: WWVB-60 signal: within 3200km (2000 miles) of Fort Collins, Colorado. To enable / disable signal reception: Press and hold VOL+ to enable, or VOL-to disable signal reception. NOTE Reception takes 2-10 minutes. If the signal is weak, it can take up to 24 hours to get a valid signal. If signal reception is unsuccessful, place your unit next to a window, press and hold VOL+ to force another signal search. Clock signal reception indicator: STRONG SIGNAL WEAK / NO SIGNAL MANUALLY SET CLOCK To set the clock manually, disable the clock signal reception first. 5 EN 1. Press and hold . 2. Press VOL+ or VOL-to cha...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории