Войти:
Оценок - 0, средний балл: 0 ( )

Инструкция по эксплуатации Philips, модель SBCSC468/00

Производитель: Philips
Размер: 2.18 mb
Название файла:
Язык инструкции:svitentresfrdenlptdafi
Перейти к скачиванию



Фрагмент инструкции


• Use the microphone sensitivity switch (A-8) to adjust the baby unit microphone sensitivity to the desired level. You can use your own voice as a sound reference. > The POWER light (A-7) on the baby unit lights up yellow when a sound is picked up. Monitoring baby silently • Use the ON/OFF switch / VOLUME control (B-9) on the parent unit to set the volume to the lowest level. Do not switch off the parent unit completely! > The sound level lights (B-1) on the parent unit visually alert you to baby’s sounds. The more sounds your baby makes, the more lights you will see. > When no sound is detected all sound level lights (B-1) will be off. Switching the night-light on and off 1 Press the baby unit night light (A-2) to switch it on and off. Features EN Switching the LINK alarm on and off You can switch on the LINK alarm on the parent unit. The LINK alarm will beep when connection between the units is lost. 1 Open the parent unit’s battery compartment (B-12) by sliding down the cover. 2 Set the switch (B-13) inside the compartment to the ON ( ) position. 3 Slide the battery compartment cover (B-12) back in place until it clicks in position. • To switch off the alarm, set the switch (B-13) to the OFF ( ) position. Connecting / disconnecting the belt clip If the parent unit is operating on batteries, you can carry it in and around your house, giving you freedom of movement while still monitoring your baby. Connecting the belt clip • Insert the little spindle on the rear of the belt clip (B-15) into the recess on the rear of the parent unit. Turn the belt clip (B-15) to the left until it clicks in position. Disconnecting the belt clip • Turn the belt clip (B-15) to the right (TURN 2) and take it off. EN Troubleshooting Problem Possible cause Solution No sound on parent unit. Volume off or too low. Turn VOLUME control (B-9) on parent unit downwards. Units out of range. Move parent unit closer to baby unit. No connection between units. Units are set to different channels. Set channel selection switches (A-9, B-11) to the same position on both units. Parent unit out of range of tansmitted signal. Move parent unit closer to baby unit. Battery pack does not charge. Battery life at an end. Replace battery pack (B-14) of parent unit. Interference or poor reception. Mobile or cordless phone(s) too close to baby monitor. Move phone(s) away from baby monitor. Interference from other baby monitors in the neighborhood. Switch both units to another channel using the channel selection switch (A-9, B-11) Battery power running low. Recharge battery pack in time. Transmitted signal is out of range; e.g. there are too many walls and/or ceilings between baby unit and parent unit. Move parent unit closer to baby unit. Parent unit located too close to a window and picking up interfering signals from other appliances. Move parent unit away from window. LINK light (B-9) flashing red / LINK alarm (B-8) beeps. Units are out of range. Interference from another baby monitor. Move units closer together. Switch to a different channel (A-9, B-11). Interference from another FM source. Remove other FM source. Frequently asked questions EN Question Answer Why does a new rechargeable It takes about 3 times full recharge and discharges before the battery pack has no full rechargeable NiMH batteries have their full capacity available. operating time capacity after the first charge? My rechargeable battery pack Leaving the rechargeable battery pack continuously connected has very short duration, why? to a charging unit can shorten it’s lifetime. If the product is not used for some time, the charged battery pack slowly looses it’s load. This is normal; a short recharge will bring it back to it’s full capacity again. The charging light (B-6) on the The charging light (B-6) is always activated as soon as the parent unit charging base (B-5) parent unit is installed. It gradually dims when the batteries are remains lit red, even after the fully charged but remains lit, indicating that the parent unit is full charge duration. Why? powered. When installed on the At this point your battery is probably completely empty. charging base, the parent unit After some 30 minutes of charging it will be possible to switch cannot be switched on the parent unit on, while installed on the charging unit. immediately. Parent unit reacts too slow/ Set microphone sensitivity on the baby unit to a higher level late on baby's cry. and/or move the baby unit closer to the baby (keep minimal distance of 1 meter / 3 feet). Parent unit reacts too quick Set microphone sensitivity on the baby unit to a lower level on other ambient sounds. and/or move the baby unit closer to the baby (keep minimal distance of 1 meter / 3 feet). The link is lost every now and You are probably approaching the outer boundaries of the then, sound interruptions etc. practical range. Try a different location or reduce the distance slightly. Please note that it takes about 30 seconds each time before a new li...

Эта инструкция также подходит к моделям:
Радионяни - SCX468/84 (2.18 mb)
Радионяни - SBCSC468/84 (2.18 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории