К этому устройству также есть другие инструкции:
Фрагмент инструкции
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS FOR THE USER
Before using the vacuum cleaner, please observe these basic precautions.
WARNING: To reduce the risk of fi re, electric shock, or injury
• This appliance is not intended for use by young children or infi rm person without supervision; young children should be supervised to ensure that
they do not play with the appliance.
• Do not use the appliance if the mains lead or plug is damaged or faulty.
• This appliance is provided with a mains lead and if this becomes damaged, it must be repaired by an Authorized Service Centre or a qualifi ed
person in order to avoid any hazard.
• Unplug from the socket outlet when not in use and before cleaning the appliance or undertaking maintenance operations.
• Turn off the appliance before removing the plug. Do not pull on the mains lead, always pull on the plug body itself.
• Do not handle plug or vacuum cleaner with wet hands.
• Do not use wet fi lters after wash, make sure they are completely dry to avoid damaging the cleaner.
• Do not vacuum fl ammable or combustible substances, neither use in areas where they may be present.
• Do not vacuum hot ash, embers or large and sharp objects.
• Do not vacuum water or other liquids.
• Keep the vacuum cleaner away from heat sources such as radiators, fi res, direct sunlight, etc.
• This vacuum cleaner is fi tted with a thermal cut-out device which automatically turns off the cleaner to prevent overheating of the motor. When
this happens, disconnect the cleaner from the socket outlet and check the dust compartment and fi lters as they may be full or clogged with fi ne
dust. Check for any other obstructions in the hose or tube. After removing the obstruction, leave the cleaner to cool down until the thermal cut-
out resets after approximately 60 minutes.
C-2
Cord rewind button (K)
A - IDENTIFICATION OF MAIN PARTS
After correct setting the dust compartment and the dust
compartment handle, pull out the total length of the mains
A) Turbine nozzle (Only MC-CL676, MC-CL675)
lead and plug into the socket outlet. To rewind the cord,
B) Floor nozzle (Only MC-CL673)
press the button.
C) Floor nozzle (Only MC-CL671)
IMPORTANT: In case it is impossible or not smooth to
D) Connection pipe
pull the mains lead, separate the dust
E) Hose (MC-CL676, MC-CL675)
compartment from the main body, then empty
(MC-CL673) (MC-CL671)
the dust compartment.
F) Suction regulator
NOTE: To pull out the mains lead smoothly, we suggest the
G) Curved wand
appliance is switched off. To secure the main fi lter
H) Telescopic wand (MC-CL676, MC-CL675)
rotation, it is advisable to pull out the mains lead
(MC-CL673) (MC-CL671)
pushing down the dust compartment handle. Please
I ) Hose inlet
hold the plug to prevent it striking you or the product.
J) ON/OFF Switch button / Variable power control
ON/OFF Switch button / Variable power control (J)
K) Cord rewind button
To start or stop the cleaner, press the button.
L) Crevice nozzle
To increase or reduce the power, turn the same button.
M) Upholstery nozzle
Manual suction control
N) Exhaust cover
The curved pipe of the hose is attached with a manual
O) Plug
suction control, which allows you to briefl y reduce the suction
P) Dust compartment handle
level.
Q) Dust compartment cover
C-3
Switching between carpet and fl ooring
R) Main fi lter
(Only
MC-CL673,
MC-CL671)
S) Pre-fi lter
Flooring:
Press
lever
A
T) Dust compartment
Carpet: Press lever B
C-4
Switching 3 positions
(Only
MC-CL676,
MC-CL675)
B - HOW TO ASSEMBLE YOUR CLEANER
Flooring (PARQUET): Set position A
Carpet (short): Set position B
B-1
Insert the connection pipe into the hose inlet and turn the
Carpet (long or hard to push): Set position C
pipe to the right.
C-5
The curved wand of the hose is attached with a manual
B-2
Insert the curved wand into the upper end of the telescopic
suction regulator, which allows you to briefl y reduce the
wand, and the fl oor nozzle to the other end. (Only MC-
suction level.
CL673, MC-CL671)
C-6
After you fi nish vacuuming, remove the plug from the
B-3
Insert the curved wand into the upper end of the telescopic
socket outlet and press the cord rewind button.
wand. Twist the telescopic wand so that the round hole will fi t
When rewinding the power cord, press the cord rewind
into the tab on the curved wand. (When removing the hose,
button by holding the plug so that it does not become
push the tab down while pulling out the telescopic wand)
damaged.
Attach the Turbine Nozzle to the other end. (Removal as per
NOTE: In case it is impossible to rewind the mains lead,
reverse procedure) (Only MC-CL676, MC-CL675)
separate dust compartment from the main body, then
B-4
Hold the grip and extension adjuster and extend telescopic
re-press the cord rewind button.
wand to the required length.
C-7
Storage position
Slide the wand holder attached to nozzle pipe straight into
the wand supporter on the under side of the main body.
C-8
Park position
C - HOW TO OPERATE YOUR CLEANER
For short breaks during vacuuming, slide the wand holder
attached to the nozzle pipe into the wand supporter on the
C-1
Pull out the mains lead and put the plug into the socket
rear side of main body.
outlet.
NOTE: When you use park position, we suggest the
NOTE: This product is provided Auto Filter Refreshing
appliance is switched off.
System which works by pulling out the mains lead.
The more the mains lead is pulled, the more this
system works well. So before starting cleaning, it
is advisable to pull out the total length of the mains
lead.
24
...Эта инструкция также подходит к моделям:
Пылесосы - MCCL673 (2.09 mb)
Пылесосы - MCCL675 (2.09 mb)
Пылесосы - MCCL676 (2.09 mb)