Войти:
Оценок - 4, средний балл: 4.5 ( )

Инструкция по эксплуатации Panasonic, модель MCV7357

Производитель: Panasonic
Размер: 1.87 mb
Название файла: MCV7357.PDF
Язык инструкции:enes
Перейти к скачиванию



Фрагмент инструкции


When dry, slide this filter back into place. Insert the secondary foam filter with a ruler or something fiat. It should be fully inserted under the plastic rib projections all the way to the rear. REPLAClNGHERAiMPEEXHAUSTFIlTER The HEPA type exhaust filter is located inside the dust cover. The purpose of this filter is to remove dust and dirt from the recirculated air. When installing a new dust bag, check this filter. When the filter Retainer becomes dirty, remove the filter and the frame from the bottom of the dust cover by pulling straight up on the two retainers on the frame. Do one side at a time Replace the filter. DO NOT CLEAN WITH WATER*. Place the new filter in the frame with the four slots in the filter aligned with the four tabs on the frame. Place the frame and the filter back into the dust cover, making sure the white side is facing up. ‘This filter cannot be cleaned and should be replaced at least once each year if the cleaner Is used at least one hour each week. Exhaust Filter (HEPA Type) and Frame Retainer Duat Cover - 14 - -■'ôsï®' CHANGING THE DUST BAG Always operate the vacuum with a genuine Panasonic Type U3 Standard, or U6 Electrostatic dust bag installed. Panasonic dust bags may be ordered through any authorized Panasonic dealer. 1. Pull outward on the dust cover grip, located on the top of the dust cover and remove the cover. 3. Spread out the end of the new dust bag. NOTE: Pull carefully so as not to tear the bag at the folds. 2. To remove the dust bag, grasp the cardboard portion of the dust bag and pull it out. - г ■ ■ CD Oo CD CD 4. Fold the new dust bag to clear the slots as shown in illustration. Failure to do so will prevent the dust cover from closing properly. Attach the new dust bag onto the bag holder by holding the cardboard portion and pushing back as illustrated. 5. Reinsert the tab provided on the end of the dust cover Into the grooves on the dust com partment to allow the cover to rotate closed. NOTE: The dust cover must be completely and correctly installed for proper operation. 6. Rotate the dust cover up into the closed position and press into place. NOTE: The dust bag should not be caught between the lower edge of the dust cover and the gasket as indicated by the arrow in the illustration. Electrical Shock or Personal Injury Hazard, When the lower plate Is removed for any reason, before reinstalling, be sure that all electrical wires are routed In a manner that prevents them from coming Into contact with the lower plate, lower plate screws, or any moving parts. Be sure that the wires are not pinched in any way when the lower plate Is reinstalled. Before replacing any parts, disconnect the vacuum cleaner from the electrical outlet. PLATE Two Locking Tabs Latchet Replacing some of the parts In this section involves the removal and Installation of the lower plate. Always place paper under nozzle anytime the lower plate Is removed to protect the floor surface. Lower Plate To Remove Lower Plate. Start by placing the handle in the upright position. See the HANDLE ADJUSTMENTS section. Turn the vacuum cleaner over, exposing the underside. Release the lower plate by pressing inward on the two (2) latches and pressing inward on the two (2) locking tabs that secure the lower plate, as shown in the illustration. Remove the lower plate and remove any residue that may exist in the belt area. To Reinstall Lower Plate. Hook the front end of lower plate into the slots on the front of the nozzle housing. Press the lower plate into place until the locking tabs snap into place, then press outward on the two (2) latches. NOTE: To ensure maximum cleaning efficiency, the belt should be checked regularly to make sure it is in good condition. Check to see if the belt is stretched, cracked, or if excessive slippage has occurred. Replace if necessary. 1. Remove the lower plate using the procedure in the REMOVING/INSTALLING THE LOWER PLATE section. 2. Grasp the bulb socket, wiggle the socket back and forth while pulling it up out of the nozzle housing. To remove the old bulb, push it in toward the bulb socket while turning counterclockwise, then remove. 3. Install the new bulb by pushing it in toward the bulb socket and turning it clockwise. Use any standard bayonet base appliance bulb rated at 15 Watts. NOTE: Do not use a bulb rated over 15 Watts. During extended use, heat from the bulb could overheat the surrounding plastic parts. 4. Reinsert the bulb socket Into the nozzle housing by pushing it back down into the slot. Replace the lower plate as outlined In the REMOVING/INSTALLING THE LOWER PLATE section. - 16- REPLACING THE BELT ^ " ■ 4 . ? A WARNING Personal injury Hazard. I Be careful when removing agitator. The belt tension is high. Failure to do so could result In personal injury from agitator releasing quickty and snapping away. Place the carpet/bare floor selector in the carpet position. Unplug and turn the unit over. ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории