Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации AEG, модель VAMPYR 731I

Производитель: AEG
Размер: 270.34 kb
Название файла:
Язык инструкции:ende
Перейти к скачиванию



Фрагмент инструкции


Manchester SK41QR Tel.: 061 4872205 Telefax: 061 474 11 91 Service Appointments Bristol Tel.: 0272 252880 (call diverted to Slough) Norfolk Tel.: 06 03 76 5515 (call diverted to Slough) AEG UK Limited Head Office 217 Bath Road Slough, Berks. SL14AW Tel.: 0753 872506 Telex: 847541 Telefax: 0753 512271 AEG Scottish Service Centre Block 11, Unit 1 Dundyvan Industrial Estate Coatbridge Lanarkshire ML5 4AQ Tel.: 0236 440387 Telefax: 0236 440256 Assembling the vacuum-cleaner ready for use The hose, tubes and accessories can befitted together by pushing and twisting, and taken apart by twisting and pulling. Fitting the suction hose and suction tube together Push the two tubes into one another and twist, to secure firmly. Connecting the suction hose Insert the hose holder into the suction opening. When the hose is to be disconnected from the appliance, press the release button and pull the hose holder out of the suction opening. 20 1/SBM1 OS/91 GB/Ell - 1 /SBM2 09/01 GB/EU - 1/SBM3 09/91 G3/EU - 1/SBM5 09/91 1/53M6 09/91 GB/EU-1/ADI 09/91 GB/Ell - 1/AK 09/01 Mains connection/Rex rewind The mains cable is located in the cable compartment. Press the foot button lor the cable, and pull the cable out Insert the plug into the socket Atthe end of vacuuming switch off and pull the plug out of the socket Press the flex rewind button and the cable rewinds automatically. Using th* cleaning head and accessory nozztos The cleaning head and nozzles are attached to the suction tube by pushing and twisting, and taken apart again by twisting and pulling. Using the floor cleaning head For care of carpets and hard floors, the cleaning head can be adjusted to suit the type of floor with your foot: for carpets Symbol for carpet brush withdrawn for hard floors Symbol for hard floor, brush extended For other optional extra floor cleaning heads see Special Accessories. 21 Accessory Nozzles - Crevice and Upholstery The integrated accessories compartment contains 2 nozzles -crevice and upholstery. Open the compartment by pressing the button vertically downwards. Crevice Nozzle For vacuuming in those normally inaccessible places i.e. reaching cobwebs, or down the side of a sofa! For vacuuming upholstery, mattresses, etc. The thread collectors help to pick up the threads and fluff. The crevice and upholstery nozzles can be attached to the suctions tubes as well as the handle of the suctions hose. 1/IBN1 09/81 GB/ELJ - 1/IBN4 07/92 GB/EU Switching on and adjusting Switching on Press the On/Off-button to switch the vacuum cleaner on or off. © ES Adjusting power - rotating/sliding regulator The vacuuming powercan be adjusted tosuitany situation with the electronic power control. 250 W = For delicate fabrics, e.g. net curtains 500 W = For upholstery 650 W = Economy setting for light to normally soiled carpets 750 W = For non--fitted carpets (mats and rugs) max = For hard floors and heavily soiled carpels m 23 HalnAenanea and cleaning Before the appliance is cleaned or maintenance in carried and ii has to be switched off arid unplugged from the mains supply. Changing the paper dustbag & ^// lit ■ Ear's m\ N HZ] The dustbag needs changing when the cleaner is set to maximum power and the cleaner head is off the floor but the “bag full" indicator window is completely coloured red. Even if the dustbag does not appear to be fullatihis stage, it should be changed. It could be that a great deal of very fine dust has clogged up the pores of the dustbag. Open the cover by pressing the button, and lifting it up until it snaps into place. -Hygienic dustbag change: when you take out the full dustbag, you automatically cover the opening by pulling on the closure tag. You may have to over-come a slight resistance as you pull. Full dustbags can be disposed of with the normal household rubbish. 24 Push the new dustbag into the guide rails as far as it will go, only then will the oover close. If no dustbag is inserted the cover cannot be shut Please do not use force! Paper dustbag sizes Please use original AEG dustbags, Size 22, ordustbags which carry the AEG Quality Seal. They are available from electrical retailers under the order-number E 618899 682, or from the AEG Service Centre under ET-No. 668 901262. Damage resulting from the use of any other dustbag is not covered by the Guarantee. 1/W1 08/93 Changing the mlcro-fitter/ultra-micro-fllter Switch off and pull out the mains plug before changing the micro-filter. Changing the micro-filter/ultra-micro-filter is necessary: For appliances wHh no micro-fitter Indicator - when the dustbag lull indicator lights up, even when aciean dustbag has been inserted, with the appliance switched on, hold the head/nozzle upwards or off the floor, if the light remains on,this indicates the micro-filter should be changed. We recommend changing the micro-1iIter with every fifth bag. For appliances with micro-filter indicator - when this comes On. The cassett...

Эта инструкция также подходит к моделям:
Пылесосы - VAMPYR 751I (270.34 kb)
Пылесосы - VAMPYR 732I (270.34 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории