Производитель: AEG
Размер: 242.31 kb
Название файла:
|
Фрагмент инструкции
Young children or infirm persons should be supervised to ensure that they do not play with the appliance. • Always store in a dry place. • Do not use to pick up liquids. • Avoid sharp objects. • Do not pick up hot cinder or lighted cigarette ends. • Do not use near flammable gases. • Avoid tugging on the mains cable and check cable regularly for damage. • WARNING: Do not pull the appliance by the cord. Do not unplug by pulling on the cord. Do not use the cleaner with a damaged cable. If the cable damaged, it should be replaced at a service center. This is not covered by the warranty. • The Plug must be removed from the socket-outlet before cleaning or maintaining the appliance. • All service and repairs must be carried out by authorised AEG-Electrolux service staff. Getting Started (see page 4) BSf* Check the dustbag is in place. Insert the hose until the catches click to engage. (Press catches inwards to release). HSf* Attach the telescopic tube to the hose handle and floor nozzle by pushing and twisting together. (Twist and pull apart to dismantle). Extend the cable and connect to mains. The cleaner is fitted with cable rewind, ensure cable is not twisted before use. (Press foot pedal to rewind. Note: Please hold the plug to prevent it striking you or the machine). BSf* Press the On/Off button to activate the cleaner. HSf* By moving the variable power control, the suction power can be adjusted. Suction can also be regulated on the hose handle by opening/closing the aperture. 9 Getting the best results (see page 5) • Carpets: Use the floor nozzle with the lever in horizontal position. • Hard floors: Use the floor nozzle with the lever in vertical position. • Loose rugs/curtains/lightweight fabrics: Reduce the suction power. Use the floor nozzle for loose rugs and the upholstery nozzle for curtains, cushions etc. • Confined areas: Use the crevice nozzle for crevices, corners and radiators. Dustbag indicator and changing the dustbag (see page 5) For peak performance the dustbag must be changed when full. If the dustbag should accidentally get broken in the cleaner, take cleaner to an AEG-Electrolux Service Centre for cleaning. Check the dustbag regularly and replace when necessary. The dustbag indicator window will gradually turn red when filling and completely red when full. To check the dustbag, the cleaner must be switched on, with all attachments connected and off the floor. The dustbag full indicator may signify that the bag is blocked (occasionally caused by very fine dust) which will cause loss of suction and may result in overheating. If this occurs change the dustbag even if it is not full. To change the dustbag Release catch and swing back lid before removing the dustbag. Kg* Remove the dustbag. IS!3 Insert new dustbag by fitting the bag slots over holders. We recommend the dustbag is changed • after using a carpet cleaning powder • if there is a bad smell from the cleaner, then you should also change the filter • Note: Use only AEG original dustbags and filters (ref GR51). Dustbag safety device: To avoid damaging the cleaner do not use it without a dustbag. A safety device is fitted which prevents the cover closing without a dustbag. Do not attempt to force cover shut. JO, Changing the filters (see page 5) There are two filters inside your cleaner. Never use the cleaner without the filters in place. To clean Motor Protection filter The Motor Protection filter should be cleaned when dirty. IE^ Pull dustbag upward and remove the motor protection filter. IE^ Rinse the filter under tap water and dry it completely. lE^ Put the filter back into the cleaner and close the cover. To change Micro filter The Micro filter should be changed with every fifth dustbag. IS!3 Open the filter grill and remove the exhaust filter. IES3 Rinse the filter under tap water and dry it completely. IES3 Put the filter back into the cleaner and close the filter grill. V 10 Troubleshooting • Power: If the electric power does not come on, disconnect from mains and check plugs, cable and fuses where appropriate. • Blockages/dirty filters: The cleaner may switch itself off in the event of a severe blockage or excessively dirty filter(s). In such cases, disconnect from mains and allow to cool for 20-30 minutes. Clear blockage and/or replace filter(s) and restart. The clearning of blocked hoses is not covered by the guarantee. • Water: If water is sucked into the cleaner the motor must be changed at an AEG-Electrolux Service Centre. • Please also see AEG-Electrolux additional information in the separate AEG-Electrolux Warranty Booklet. The symbol /tA on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences ...
Эта инструкция также подходит к моделям:Пылесосы - ELECTROLUX 485 (242.31 kb)