This will prevent build-up of alkaline residue in the system. If spray jets become clogged, remove the spray tips, wash them thoroughly, and blow-dry. NOTE: Do not use pins, wire, etc. to clean nozzles as this could destroy spray pattern. Periodically inspect all hoses, electrical cables and connections on your machine. Frayed or cracked hoses should be repaired or replaced to eliminate vacuum or solution pressure loss. If the cable insulation is broken or frayed, repair or replace it immediately. Don’t take chances with electrical fire or shock. DAILY / REGULAR MAINTENANCE Before making any adjustments or repairs to the machine, disconnect the power cord from electrical source. 1. Empty unused cleaning solution from the solution tank. 2. Inspect and clean filter screen in solution tank. 3. Flush pumping system with 4 or 7 liters of clean, hot water. 4. After each use, rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a 1-10 bleach to water solution. Waste water should be disposed of properly. 5. Check for and remove any lint or debris around vac shoe. 6. Check spray jets for full spray pattern. 7. Remove lint and dirt build-up from brush and housing. NOTE: Brush removal. A. To remove brush, grab and pull brush out from end opposite drive belt (operator’s right). Remove other end from brush driver. B. To install brush, line up slots in brush core with pin in driver on drive belt side (operator’s left) and push brush onto driver. Then snap bearing end (opposite end) of brush into retaining clip. 8. Check cooling air screen (located on frame behind left wheel) for lint or debris. 9. Check float and shut-off screen and clean as necessary. NOTE: Always store machine with brush in “Store” position. ADMIRAL 86038230 03/16/07 MAINTENANCE ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE ! WARNING: FOLLOWING REPAIRS. VACUUM MOTOR REPLACEMENT 1. Turn off all switches and unplug machine. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame. 4. Locate the vacuum motor wires and disconnect at the connector. Close the solution tank. 5. Remove the (6) screws holding the vacuum motor cover (p/n 27809) to the solution tank. 6. Remove the vacuum motor. 7. Reverse process to install vacuum motor. Important: These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely. Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long. 3/8 (9.5mm) Vacuum Motor Carbon Brushes Replacement (Ametek) Note: When replacing carbon brushes loosen wire terminal BEFORE removing screws on bracket. Note: Place stop in groove. Wire Terminal WARNING: The green ground wire must be attached for safe operation. See wiring diagram. End Cap Carbon Brushes Vacuum Motor Carbon Brushes Replacement (Windsor) WARNING: The green ground wire must be attached for safe operation. See wiring diagram. End Cap Carbon Brushes If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center. Important: These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely. Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long. 38 [9.5mm] Wire Terminal If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center. 4-3 ADMIRAL 86038230 03/16/07 MAINTENANCE WARNING: ! ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS. PRV NO. 62759 BELT REPLACEMENT 86249420 1. Turn off all switches and unplug machine. 2. Remove recovery tank and brush. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame. 4. Loosen the (4) screws that hold the brush motor in place and slide motor forward to release tension in belt. 5. Remove the (2) screws that fasten the vacuum shoe links (p/n 05016) to the brush housing. 6. Remove the (3) screws that fasten the side plate (p/n 62759) to the brush housing to remove belt. NOTE: All components associated with driving the brush will come out with the side plate. 86287330 PRV NO. 05016 7. Reverse process to install belt. ADMIRAL 86038230 03/16/07 WIRING DIAGRAM 86238820 PRV NO. 41351 86268290 PRV NO. 88229 86268460 PRV NO. 88333 86268430 PRV NO. 88323 86238840 PRV NO. 41356 8638830 PRV NO. 41355 86266890 PRV NO. 88655 86266720 PRV NO. 880043 ADMIRAL 86038230 03/16/07 TROUBLESHOOTING CHART PROBLEM CAUSE SOLUTION No Power, Nothing Runs Is the cord plugged in. Plug in cord. Circuit breaker tripped in...
Эта инструкция также подходит к моделям:Пылесосы - ADM8 10080170 (2.1 mb)