Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации Avaya, модель 16-300310

Производитель: Avaya
Размер: 196.93 kb
Название файла: c183a83f-6e0c-4975-ab50-01fccfc65e29.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


When setting up these systems, you will need to know the following: . Maximum number of VSX/HDX, V500, and V700 systems on your network. . PIN for each VSX/HDX/V500/V700 system. The PIN can consist of a maximum of eight numeric characters and is defined by the System Administrator. . The key code that combines the Avaya option with any other Polycom options. . If the VSX/HDX system has the multipoint option or IMCU option. If so, you must combine the Polycom Software License for this capability with the Avaya Option Polycom Software License to create a single Key Code to input into the unit. . IP address of the voice system . IP codec sets you want to use . IP network regions you want to use AVTS R 6.0 Quick Setup For feedback, use document@avaya.com August 2010 14 Configure H.323 video endpoints on Communication Manager 6.0 Configuring Polycom Endpoints Use this procedure to configure the Video calling facility for all Polycom endpoint users. Table 6: Configuring Polycom Endpoints 1 Enter display system-parameters customer-options to verify the Maximum Video Capable Stations (page 2 of screen). This number is provided by the RFA license file. The Maximum Video Capable Stations was determined using the following criteria: . Each V500/700 system is considered to be one station . Each single-point VSX/HDX system is considered to be one station . Each VSX multpoint system can be three to six stations Each HDX system can be three stations for multipoint plus four and seven for multipointplus eight multipoint licensed options for the HDX9004. The HDX9002 only has multipoint plus 4 as an option. 2 Enter change cos to set Priority Video Calling (page 2 of screen) for the appropriate COS levels. 3 Enter add station to add a station for the Polycom system. Set the following parameters: . Type :H.323 . Security Code : the “pin” you will administer for the VSX, HDX, V500 or V700 system . IP Video : y . If you want this station to be able to make priority video calls, make sure you select a COS level that has Priority Video Calling enabled. (See Step 2) . On page 2 of the screen, set Direct IP-IP Audio Connections to y Note: You can create an alias for VSX/HDX stations. Add Users/stations to Polycom endpoints Use this procedure to add users/stations to the Polycom endpoints. AVTS R 6.0 Quick Setup For feedback, use document@avaya.com August 2010 15 Configure H.323 video endpoints on Communication Manager 6.0 Table 7: Add users/stations to Polycom endpoints 1 Install the Polycom system and connect it to your network. 2 Upgrade the Polycom system software (if necessary). 3 Using a web browser, access the Polycom home page for the unit, and select Admin Settings > Network > IP Network. 4 Check the Enable IP H.323 check box. 5 Check the Display H.323 Extension check box. 6 In the H.323 Extension (E.164) box, enter the station number you specified for this system on the Avaya Communication Manager system. 7 From the Use Gatekeeper box, select Specify with PIN. 8 In the Gatekeeper IP Address box, enter the IP address of the CLAN or PCLAN followed by: 1719 (to specify the correct port to use). 9 In the Authentication PIN box, enter the security code you entered in Step 5. 10 In the Number box in the Gateway area, enter the extension you specified in Step 8. 11 Select the Enabled PVEC check box. 12 In the Type of Service box in the Quality of Service area, select the appropriate setting. Both IP Precedence and Diffserve are supported. Contact your Network Administrator for this information. 13 In the Type of Service Value boxes (Video, Audio, and Far End Camera Control), enter the QoS values for the IP Network Region settings in which the VSX/HDX station belongs. 14 Select the Dynamic Bandwidth check box. 15 From the Maximum Transmit Bandwidth box, select the setting that matches the Maximum Call Rate for Direct-IP Multimedia setting you specified for the Avaya Communication Manager system. 16 From the Maximum Receive Bandwidth box, select the setting that matches the Maximum Call Rate for Direct-IP Multimedia setting you specified for the Avaya Communication Manager system. 17 Complete the Firewall and Streaming sections as necessary. 18 When finished, click the Update button. 19 Repeat Steps 1 through 18 for each Polycom system. AVTS R 6.0 Quick Setup For feedback, use document@avaya.com August 2010 16 Configure H.323 video endpoints on Communication Manager 6.0 Configuring Polycom RMX Series Video Conferencing Bridge Platform Use this procedure to configure the Polycom RMX series video conferencing Bridge platform. Table 8: Configuring Polycom RMX Series Video conferencing on Bridge Platform 1. Enter change node-names ip to add an entry for the RMX system. Be sure to enterthe IP address of the IP board for the RMX system. 2 Enter add trunk-group to add a two-way trunk group for the RMX system. Set the following parameters: . Group Type: ISDN . Direction: Two-way . Carrier Medium: H.323 . Service Type: Tie 3 Enter add signal...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории