Added new cmdlets
The following cmdlets have been added:

Set-HPiLOIPv6NetworkSetting: Modifies the IPv6 network settings of the host server where
the iLO is located.

Get-HPiLOServerInfo: Gets the host server embedded health by iLO.
Updated cmdlet parameters

Set-HPiLOSharedNetworkPort: Added new parameter SNPPort for iLO 4 Version 2.00.

Set-HPiLONetworkSetting: Added new parameter ILONICAUTO_SELECT for iLO 4 Version
2.00.

Find-HPiLO: Added SerialNumber and UUID property.

Get-HPiLOModuleVersion: Show current and available UICulture.
New language support
Added support for Simplified Chinese and Japanese in addition to English.
Other enhancements

Changed write-host to write-error for the errors that would terminate cmdlet execution. Changed
write-host to write-warning for warning messages.

Added samples scripts located in the directory where you unzipped the HPiLOCmdlets install
package.

Enhanced parameter validation to check the correctness of input parameters before sending a
command to iLO.
NOTE:
More detail about the following three enhancements is included in the HP Scripting Tools for
Windows PowerShell User Guide iLO Cmdlets.

Support for Invoke-HPOAiLOCommand for interoperation of iLO and Onboard Administrator
cmdlets.

Support for credential parameter for each cmdlet.

Enhanced pipeline processing, which enables user piping parameters to iLO cmdlets in multiple
ways.
Fixes
The following items are fixed in this release:

Corrected issue of cmdlets not taking string/array as parameters in pipeline mode.

Corrected parameter handling for array input. After changing, parameters are matched by array
element one at a time.

Corrected an issue where cmdlets are not executed successfully with the force parameter.

Corrected an issue where uninstalling iLO cmdlets removes an environment variable which causes
OA cmdlets to fail.

Removed unused parameter WebAgentIPAddress in Set-HPiLONetworkSetting.

Corrected an issue that caused a syntax error with
Add-HPILOSSORecord/Import-HPiLOSSHKey.