|
Фрагмент инструкции
wrench, remove the two gauge bracket screws/nuts (Figure 24). 3. Remove the gauge bracket and the gauge from the inside of the oxygen door. Gauge Bracket Screws Gauge Bracket Bracket Gauge Figure 24. Front View of the New-style Figure 25. Rear View of the New-style Gauge (mounted on door) Gauge (removed from door) Installation of New-style Gauge 1. Order the following from SSCI: • New-style Gauge - P/N 854771 • Gauge Bracket -P/N 600162-2 Note: Order a new gauge bracket only if replacing an old-style gauge. If replacing a new-style gauge, use your existing bracket. 2. Loosely mount the gauge bracket (Figure 25) onto the inside of the oxygen door with the screws and nuts removed above. Use the existing gauge bracket mounting holes. 3. Place the gauge into the gauge bracket making sure the gauge is right-side-up. 4. Tighten the bracket screws and nuts to secure the gauge. 5. On the front of the polycarbonate door, mark the centers of the two buttons on the face of the gauge (Figure 12). Form No. 702703 Rev. E August, 2006 23 Chapter 4 - Repairs and Replacements 6. Loosen the gauge bracket nuts and remove the gauge from the door. 7. With a 1/16 in. bit, drill two holes in the door at the locations marked in Step 5 (Figure 26). This will provide easy access to the buttons on the front of the gauge. 8. Smooth out the outside and inside edges of the holes to eliminate any rough edges. 9. Remove the tape marked “REMOVE TO START” from the battery compartment. When the tape is removed, the gauge will begin operating. 10. Position the Centigrade/Fahrenheit (°C / ° F) slide switch to display the preferred units (Refer to Page 13). 11. Place the gauge into the gauge bracket, again making sure the gauge is right-side-up. 12. Tighten the screws and nuts to secure the gauge. Drill Holes Here Figure 26. Drilling Button Access Holes SSCI - Suburban Surgical Company, Inc. Owner’s Manual - Oxygen Therapy Door Ice Tray Hang the new ice tray on the button hooks provided on the door (Figures 27 and 28). P/N 202975 Ice Tray Button Hooks Ice Tray Figure 27. Ice Tray Button Hooks Figure 28. Ice Tray in Place Ice Tray Valve Tools Required • Pliers P/N 854545 • Utility knife Procedure 1. Remove the ice tray from the oxygen therapy door. 2. If tubing is attached to the valve barb fitting, pull or cut it off. 3. Holding the valve body with a pliers, unscrew the valve from the tray. 4. Screw the new valve into the tray. 5. Reattach any tubing that was connected to the old valve. 6. Hang the ice tray on the oxygen therapy door. Form No. 702703 Rev. E August, 2006 25 Chapter 4 - Repairs and Replacements Seal Strip Retainer and Seal Strip Refer to Tables 3 and 4 for Part Numbers The following instructions cover both the seal strip retainers and the seal strips. All seal strip retainers are the same except for length and number of mounting holes. The same is true for all seal strips. Parts Identification Table 3 on Page 27 and Table 4 on Page 28 give the part numbers for the various seal strip retainers and seal strips. Note: The dimensions refer to the door/cage size, and not to the actual lengths of the retainers and seals. Tools Required • 3/8 in. box-end or open-end wrench • Phillips screwdriver Procedure Note: You do not have to remove the door from the cage to replace a seal strip retainer or a seal strip. 1. Open the oxygen therapy door. 2. With a 3/8 in. wrench and a Phillips screwdriver, remove the mounting nuts and screws (Figures 29 and 30) that hold the seal strip retainer and seal strip to the door. Note: The number of mounting screws/nuts varies with the dimensions of the door. Seal Strip Mounting Screw Mounting Nut Seal Strip Seal Strip Retainer Figure 29. Outside View - Seal Strip and Figure 30. Inside View - Seal Strip Retainer Mounting Screws Retainer and Seal Strip 3. Lift off the seal strip retainer. 4. If you are replacing the seal strip, remove it at this time. SSCI - Suburban Surgical Company, Inc. Owner’s Manual - Oxygen Therapy Door 5. If you are replacing the seal strip, hold the new strip in position. 6. Hold the new or existing seal strip retainer in position. 7. Secure the seal strip and retainer to the door with the screws/nuts you removed in Step 2. 8. Close the door and observe the seal to be sure it works satisfactorily. Door Model Door Dimensions Seal Strip Retainer P/N Quantity 12155-00-DRDRAANew P/N: 102563-1Old P/N: x 24 in. H24 in. W 60.96 cm W x 60.96 cm H 605365All 4 Sides 605365Top/Bottom 605367R & L Sides 605367Top/Bottom 4 12155-00-DREPAANew P/N: 102566-1Old P/N: 24 in. W x 30 in. H 60.96 cm W x 76.20 cm H 2 2 12155-00-EPDRAANew P/N: 102564-1Old P/N: 30 in. W x 24 in. H 76.20 cm W x 60.96 cm H 2 605365R & L Sides 2 12155-00-EPEPAANew P/N: 102567-1Old P/N: 30 in. W x 30 in. H 76.20 cm W x 76.20 cm H 605367All 4 Sides 4 12155-00-EPFNAANew P/N: 102568-1Old P/N: 36 in. W x 30 in. H 91.44 cm W x 76.20 cm H 605009Top/Bottom 2 605367R & L Sides 605363Top/Bottom 605367R & L Sides 605009All 4 Sides 605363To...
Эта инструкция также подходит к моделям:Прочие персональные приборы - OXYGEN THERAPY DOOR 12155-00-DRDRAA (1.56 mb)
Прочие персональные приборы - OXYGEN THERAPY DOOR 12155-00-DREPAA (1.56 mb)
Прочие персональные приборы - OXYGEN THERAPY DOOR 12155-00-EPDRAA (1.56 mb)
Прочие персональные приборы - OXYGEN THERAPY DOOR 12155-00-EPEPAA (1.56 mb)