|
Фрагмент инструкции
In places with high dust or soot levels, maintenance may need to be performed more often. Refer to Preventive Maintenance Record on page 25. Routine Maintenance NOTE: The following routine maintenance should be performed more frequently. See recommended intervals in each section and preventive maintenance record. Cleaning the Cabinet Filter CAUTION DO NOT operate the concentrator without the filter installed. NOTE: For this procedure, refer to FIGURE 6.1 on page 24. NOTE: There is one cabinet filter located on the back of the cabinet. 1. Removethefilterandcleanatleastonceaweekdepending on environmental conditions. NOTE: Environmental conditions that may require more frequent cleaning of the filters include but are not limited to: high dust, air pollutants, etc. Part No 1143482 23 Perfecto2 ™Series SECTION 6—MAINTENANCE Perfecto2 ™Series 24 Part No 1143482 2. Clean the cabinet filter with a vacuum cleaner or wash in warm soapy water and rinse thoroughly. 3. Dry the filter thoroughly before reinstallation. FIGURE 6.1 Cleaning the Cabinet Filter Cleaning the Cabinet Clean the cabinet with a mild household cleaner and non.abrasive cloth or sponge. Cleaning the Humidifier NOTE: To clean the oxygen humidifier, follow the instructions provided by the manufacturer. If none are provided, follow these STEPS: 1. Clean the humidifier every day. 2. Wash it in soapy water and rinse it with a solution of ten parts water and one part vinegar. 3. Rinse thoroughly with hot water and refill with distilled water to the level shown on the humidifier. SECTION 6—MAINTENANCE MODEL NO. IRC SERIAL NO. PREVENTIVE MAINTENANCE RECORD ON EACH INSPECTION Record Date of ServiceRecord Elapsed Hours On Hour MeterClean Cabinet Filter(s)Check Prescribed L/min. Flow RateEVERY 4,380 HOURSCheck Oxygen Concentration(UNITS WITHOUT SensO 2 ) EVERY 26,280 HOURS OR 3 YEARS, WHICHEVER COMES FIRST ( Check Oxygen ConcentrationUNITS WITH SensO 2 )DURING PREVENTIVE MAINTENANCE SCHEDULE, OR BETWEEN PATIENTS Clean/Replace Cabinet Filter(s)Check Outlet HEPA Filter*Check Compressor Inlet Filter*Check Power Loss AlarmAS REQUIREDClean Heat ExchangerReplace Exhaust MufflerRebuild Top End of Compressor *NOTE: Refer to Preventive Maintenance NOTE: 4,380 hours are equivalent 26,280 hours are equivalent FIGURE 6.2 Preventive Maintenance Record Part No 1143482 25 Perfecto2 ™Series SECTION 7—TROUBLESHOOTING GUIDE SECTION 7—TROUBLESHOOTING GUIDE SYMPTOM: PROBABLE CAUSE: SOLUTION: Alarm: Short beeps, long pause Main Power Loss: 1. Power cord not plugged in. 1. Insert plug into outlet. Concentrator not operating, power switch On. Beep......Beep...... 2. No power at outlet. 2. Inspect house circuit breakers or fuses. If problem recurs, use a different outlet. 3. Tripped circuit breaker. 3. Call Service Provider. Alarm: Continuous System Failure: 1. Unit overheating due 1a. Remove and clean cabinet filters. Concentrator not operating, Power Switch On. to blocked air intake. 1b. Move oxygen concentrator at least three inches away from walls, draperies or furniture. Beeeeeeeep.... 2. Insufficient power at outlet. 2. DO NOT use extension cords. Move to another electrical outlet or circuit. 3. Internal repairs required. 3. Call Service Provider. Alarm: Rapid Beep....Beep... Beep...Beep Low Flow Alarm: 1. Kinked or blocked tubing, cannula or humidifier. 1. Inspect for kinks or blockages. Correct, clean or replace item. Once corrected, turn power Off for 60 seconds and then turn power back ON. 2. Flowmeter set at 0.5 L/min or less. 2. Reset flowmeter to prescribed flowrate. If prescribed flowrate is below 0.5 L/min, use the Pediatric Flowmeter IRCPF16 (Only with Perfecto2 5). Perfecto2 ™Series 26 Part No 1143482 SECTION 7—TROUBLESHOOTING GUIDE SYMPTOM: PROBABLE CAUSE: SOLUTION: YELLOW or RED light Illuminated. Alarm: Continuous On RED light only. 1. Low oxygen purity.* 1. Clean or Replace filters. 2. Kinked or blocked tubing, cannula or humidifier.* 2. Inspect for kinks or blockages. Correct, clean or replace item. Once corrected, turn power Off for 60 seconds and then turn power back On. * Only applies to IRC5PO2. 3. Flowmeter set at 0.5 L/min or less.* 3. Check flowmeter is set to 1.0 L/min or more. 4. Unit overheating due to blocked air intake. 4a. Remove and clean cabinet filters. 4b. Move concentrator at least three inches from walls, draperies, and furniture. 5. Insufficient power at outlet. 5. DO NOT use extension cords. Move to another electrical outlet or circuit. 6. Internal repairs required. 6. Call Service Provider. GREEN light with YELLOW Light Flashing. 1. Internal repairs required. 1. Call Service Provider. Part No 1143482 27 Perfecto2 ™Series NOTES NOTES Perfecto2 ™Series 28 Part No 1143482 NOTES NOTES Part No 1143482 29 Perfecto2 ™Series NOTES NOTES Perfecto2 ™Series 30 Part No 1143482 LIMITED WARRANTY LIMITED WARRANTY NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975. This warranty is ext...
Эта инструкция также подходит к моделям:Прочие персональные приборы - IRC5PO2V (1.57 mb)