Инструкция по эксплуатации Amtrol, модель EXTROL 200 LBC

Производитель: Amtrol
Размер: 789.42 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


6. The EXTROL® may now be piped to the system (use the suggested EXTROL® piping diagrams on the next page). 7. Using the table below, select appropriate pipe size. Connection to each EXTROL® must have a lock shield gate valve and union to allow isolation and removal if required. Make up and fill valves, whether manual or automatic, should be tied into the connecting line. This will ensure that pump operation will not affect valve operation. operational Limits Maximum Operating Pressure: As stamped on nameplate Maximum Operating Temperature: 240 °F Minimum Operating Temperature: 35°F (non-glycol application) If unit is being installed in a glycol system where minimum temperatures fall below 35°F, contact the AMTROL technical service department at (401) 535-1216. operating Instructions 1. Check the expansion tank pre-charge before the system is filled with water. The charge is 12 psig unless noted otherwise on the tank label. Check to make sure this is the correct pre-charge pressure specified for the system. 2. If the tank pre-charge pressure needs to be changed on a dry system follow the following procedure: a. Check the expansion tank air pressures at the pre-charge connection with an accurate tire type pressure gauge. The pre-charge connection is the same kind of connection found on automobile tires. b. If the pressure is low, charge the tank with nitrogen gas or with oil free compressed air. Check the pressure frequently during this process as you would when filling a tire with air. dANGEr: Excessive pressure can cause tank to explode. Exercise care when filling a tank with air so the pressure does not exceed that required or does not exceed the working pressure of the tank as stamped on the nameplate. Failure to follow these instructions will result in serious personal injury or death and property damage. 3. If, after the system has been filled with water and operating, it is found that the expansion tank pre-charge must be changed use the following procedure: a. Turn off the heat source and allow the system water to cool to ambient temperature. IMPorTANT: Expansion tank cannot be properly air charged other than at ambient temperature. b. Close the lock-shield valve in the tank-to-system piping. c. Open the drain valve to empty the water from the tank. d. Check the tank air pressure at the pre-charge connection with an accurate tire type air gauge. e. Refer to 2b above. f. Close the drain valve, open the lock-shield valve and turn on the heat source. g. Relock the lock-shield valve. Firing rate of Boiler Length of Pipe Connecting Tank to System: MBTU/H 2,000 4,000 8,000 12,000 16,000 20,000 Below 11’ 1/2” 3/4” 1” 1 1/4” 1 1/4” 1 1/2” 11’ – 30’ 3/4” 1” 1 1/4” 1 1/2” 2” 2” 31’ – 100’ 1” 1 1/4” 1 1/2” 2” 2 1/2” 2 1/2” SUGGESTEd PIPING dIAGrAMS ALTErNATE PIPING dIAGrAMS AMTroL INC. LIMITEd ProdUCT WArrANTY AMTroL INC. LIMITEd ProdUCT WArrANTY Products covered: all Products manufactured by AMTroL Inc. (“AMTroL”) . This warranty cannot be transferr...

Эта инструкция также подходит к моделям:
Прочие персональные приборы - EXTROL 300 LBC (789.42 kb)
Прочие персональные приборы - EXTROL 130 LBC (789.42 kb)
Прочие персональные приборы - EXTROL 165 LBC (789.42 kb)
Прочие персональные приборы - EXTROL 400 LBC (789.42 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории