Войти:
Оценок - 2, средний балл: 3 ( )

Инструкция по эксплуатации Precision Trading, модель PM5200

Производитель: Precision Trading
Размер: 311.22 kb
Название файла: e5dd2ce3-18f0-4e24-9170-b5df5e28b896.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067 USA Fax: (+001) 610-262-6080 CONTENTS RECEIVING / INSPECTION.........................................................2 INTENDED USE..........................................................................2 READ ALL INSTRUCTIONS BEFORE USING ............................2 ExPLANATION OF ABBREVIATIONS.........................................2 SAFETY INFORmATION - WARNINGS AND CAUTIONS...........3 SPECIFICATIONS ......................................................................5 DIAGRAmS..................................................................................7 COmPONENT DESCRIPTION ....................................................8 COmPONENT DESCRIPTION ....................................................9 ALARm TEST.............................................................................10 REVERSE GAS FLOW PROCEDURE.......................................10 OPERATING INSTRUCTIONS...................................................10 PERFORmANCE CHECk..........................................................11 CLEANING ................................................................................11 mAINTENANCE.........................................................................12 TECHNICAL DESCRIPTION .....................................................12 RETURNS..................................................................................12 DISPOSAL INSTRUCTIONS .....................................................12 TROUBLESHOOTING...............................................................13 LImITED WARRANTY ...............................................................14 DECLARATION OF CONFORmITY...........................................15 Blender Air-Oxygen 1 RECEiViNg / iNSPECTiON Remove the Precision medical, Inc. Air-Oxygen Blender from the packaging and inspect for damage. If there is any damage, DO NOT USE and contact your Provider. iNTENdEd USE Precision medical, Inc. Air-Oxygen Blender dispenses a continuous and precise blend of medical air and USP oxygen via outlet ports to infant, pediatric and adult patients. The exact Fractional Concentration of Inspired Oxygen (FiO2) blend of gases corresponds to the dialed in FiO2 setting indicated by the control knob (dial). REAd ALL iNSTRUCTiONS BEFORE USiNg This manual instructs a Professional to install and operate the Air-Oxygen Blender. This is provided for your safety and to prevent damage to the Air-Oxygen Blender. If you do not understand this manual, DO NOT USE the Air-Oxygen Blender and contact your Provider. dANgER This product is not intended as a life-sustaining or life- supporting device. ExPLANATiON OF ABBREViATiONS FiO2 Fractional Concentration of Inspired Oxygen DISS Diameter Indexed Safety System NIST Non-Interchangeable Screw Thread psi Pounds Per Square Inch lpm Liters Per minute Blender Air-Oxygen 2 SAFETy iNFORMATiON - WARNiNgS ANd CAUTiONS WARNiNg CAUTiON CAUTiON dANgER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage. CONSULT ACCOmPANYING DOCUmENTS Symbol for “USE NO OIL” Symbol indicates the device complies with the requirements of Directive 93/42/EEC concerning medical devices and all applicable International Standards. (On CE marked devices ONLy) WARNiNg • • • • • Only trained, qualified medical personnel under the direct supervision of a licensed physician should operate the Air-Oxygen Blender . Use this Air-Oxygen Blender only for its Intended Use as described in this manual. Confirm prescribed dose before administering to patient. monitor on a frequent basis. The Air-Oxygen Blender shall be serviced by a qualified service technician. Always follow ANSI and CGA standards for medical Gas Products, Flowmeters and Oxygen Handling. Blender Air-Oxygen 3 WARNiNg • • • • • • • • An Oxygen Analyzer/monitor must be used to verify oxygen concentration. Accuracy of oxygen concentration will be affected if bleed is not activated at flow settings below 15 lpm for the High Flow Blender, and 3 lpm for the Low Flow Blender. dO NOT obstruct the alarm. dO NOT use Blender when alarm is sounding. dO NOT use oil in or around the Blender. dO NOT occlude or obstruct the bleed port on the auxiliary outlet of the Blender. dO NOT use near any type of flame or flammable/ explosive substances, vapors or atmosphere. Oxygen Concentration dial does not rotate 360 degrees. Rotating the dial less than 21% or over 100% oxygen will damage the Blender. CAUTiON • • • • • • • • • • • Turn off gas supplies when Air-Oxygen Blender is not in use. Store...

Эта инструкция также подходит к моделям:
Прочие персональные приборы - PM5300 (311.22 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории