Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации ResMed, модель Positive AirwAy Pressure Device S8 Elite II

Производитель: ResMed
Размер: 221.17 kb
Название файла: ba4a6bc4-dc02-4741-aa5e-d7f8cc5e0f43.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


The keypad backlight is always on while the S8 Series II is on. Selecting the Mask Type To ensure your device functions as intended with your selected mask, you need to select the mask type that you are using. 1 With the RAMP or SETTLING screen displayed, press . (In CPAP mode, the standby screen displays RAMP. In AutoSet mode (S8 AutoSet Spirit II only) the standby screen displays SETTLING.) 2 Press until MASK is displayed. 3 Press to change the setting. 4 Press or until you see the setting that you require. 5 Press to apply. Using the Mask-fitting Feature You can use the S8 Series II mask-fitting feature to help you fit your mask properly. This feature delivers air pressure for a three-minute period, prior to starting treatment, during which you can check and adjust your mask fit to minimise leaks. Note: Make sure that the mask setting on the MASK screen is the same as the mask you are using. 1 Fit your mask as described in the mask user instructions. 2 With the RAMP or SETTLING screens displayed, hold down for at least three seconds until air pressure delivery starts. Your device will ramp to the mask-fit pressure and will remain at this pressure for three minutes. The following displays on the LCD screen indicating that the mask-fitting feature is operating, where: ***** is an excellent fit;****- is a very good fit; ***-- is a good fit; while **---, *---- and ----- each require you to adjust your mask. MASK FIT: ***** excelnt 3 Adjust your mask, mask cushion and headgear until you have a secure and comfortable fit. After three minutes, the pressure reverts to the set pressure and treatment will begin. If you do not wish to wait three minutes, hold down for at least three seconds to start treatment immediately. If you press for less than three seconds, the unit will return to standby mode (the RAMP or SETTLING screen). Starting Treatment 1 Make sure the power is on. The product name is displayed briefly on the screen, then the standby screen displays RAMP (or SETTLING). The key and LCD backlights also turn on. 2 Lie down and arrange the air tubing so that it is free to move if you turn in your sleep. ! CAUTION Do not leave long lengths of air tubing around the top of your bed. They could twist around your head or neck while you are sleeping. 3 Alter the ramp or settling time if required. English Using the S8 Series II 4 To start treatment, press . 5 Fit your mask as described in the mask user instructions. WARNING A mask should not be used unless the S8 Series II device is powered and operating properly. Stopping Treatment To stop treatment at any time, remove your mask and press . If your clinician has enabled SmartStart, simply remove your mask and treatment will end. Changing the Settings on your S8 II Device You can change settings (such as Ramp Time, EPR Level) on S8 II devices by using the keypad and LCD. When the device is in standby mode you can display a series of screens (a menu) on the LCD screen in order to view and change the settings for a particular function. The Standard Menu Your clinician will have enabled a standard menu on your S8 Series II device. The figure below shows the standard menu in each mode. To enter the standard menu from the standby (RAMP or SETTLING) screen, press . CPAP AUTOSET ! RAMP: 10min menu WELCOME >>>>>> EPR LEVEL: 1 change exit MASK: ULTRA change exit exit SW: SX4800100 USED HRS: 08000 exit USAGE: 1000/1068 exit * SETTLING: 10min menu WELCOME >>>>>> MASK: ULTRA change exitSW: SX4800100 USED HRS: 08000 exit USAGE: 1000/1068 exit EPR LEVEL: 1 change exit * exit * Only displayed if access set by clinician. Note: The AutoSet menu is available on the S8 AutoSet Spirit II only. The Detailed Menu Your clinician may have enabled a detailed menu on your S8 Series II device. The figure below shows the detailed menu in each mode. To enter the detailed menu from the standby (RAMP or SETTLING) screen, press . Note: The AutoSet menu is available on the S8 AutoSet Spirit II only. RAMP: 10min menu WELCOME >>>>>> SETTINGS enter exit SETTLING: 10min menu WELCOME >>>>>> EPR LEVEL: 1 change exit MASK: ULTRA change exit TUBE LENGTH: 2m change exit HUMID: NONE change exit SMARTSTART: ON change exit LEAK ALERT: OFF change exit CPAP AUTOSET MASK: ULTRA change exit TUBE LENGTH: 2m change exit HUMID: NONE change exit SMARTSTART: ON change exit LEAK ALERT: OFF change exit AUTOSET CPAP USED HRS: 08000 exit USAGE: 1000/1068 exit RESULTS enter exit SERVICING enter exit OPTIONS enter exit LANG: ENGLISH change exit SN: 12345678912 exit PCB: 123456789123 4567 exit SW: SX4800100 exit SMART DATA enter exit SMART DATA enter exit AUTO APPEAR: OFF change cancel EPR LEVEL: 1 change exit * * Only displayed if access set by clinician. ** * * English Changing the Settings on your S8 II Device Messages on the S8 Series II LCD Your clinician may have set your S8 Series II device to remind you about important events, such as when to replace your mask, when to insert your Data Card (if your device is Data C...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории