Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации ResMed, модель VPAP ST

Производитель: ResMed
Размер: 1.23 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Only ResMed products are designed to be connected to the data communication port. Connecting other devices could result in injury, or damage to the VPAP device. • These VPAP devices should only be used with masks (and connectors ) recommended by ResMed, or by a physician or respiratory therapist. A mask should not be used unless the VPAP device is turned on and operating properly. The vent hole or holes associated with the mask should never be blocked. Explanation: These VPAP devices are intended to be used with special masks (or connectors ) which have vent holes to allow continuous flow of air out of the mask. When the device is turned on and functioning properly, new air from the device flushes the exhaled air out through the mask vent holes. However, when the device is not operating, insufficient fresh air will be provided through the mask, and the exhaled air may be rebreathed. Rebreathing of exhaled air for longer than several minutes can, in some circumstances, lead to suffocation. This applies to most models of PAP devices. In the event of power failure1- or machine malfunction, remove the mask. These VPAP devices can be set to deliver pressures up to 25 cm H2O. In the unlikely event of certain fault conditions, pressures up to 40 cm H2O are possible. Follow all precautions when using supplemental oxygen. Oxygen flow must be turned off when the flow generator is not operating, so that unused oxygen does not accumulate within the flow generator enclosure and create a risk of fire. If the oxygen has been left on, turn off the device, then wait 30 minutes before turning on the device again. Do not use the VPAP Auto 25, VPAP ST or VPAP S if there are obvious external defects or unexplained changes in performance. Do not open the VPAP case. There are no user serviceable parts inside. Repairs and internal servicing should only be performed by an authorized service agent. Explosion hazard - do not use in the vicinity of flammable anesthetics. Cautions At low pressures, the flow through the exhalation ports of your mask may not clear all exhaled gas from the tubing. Some rebreathing may occur. The airflow for breathing produced by this device can be as much as 11°F (6°C) higher than the temperature of the room. Caution should be exercised if the room temperature is warmer than 90°F (32°C). When AC mains power (100-240V AC) is not available, always use a ResMed DC/DC converter 24V/50W output converter. (The DC/DC converter 24V/50W output converter is available as an optional accessory.) Note: The above are general warnings and cautions. Specific warnings, cautions and notes appear with the relevant instructions in the manual. * Ports may be incorporated into the mask or in connectors that are near the mask. 1 During partial (below rated minimum voltage) or total power failure, therapy pressures will not be delivered. When power is restored, operation will recommence with no change to settings. 16 Guidance and Manufacturer's Declaration - Electromagnetic Emissions and Immunity Guidance and manufacturer's declaration - electromagnetic emissions The VPAP Auto 25, VPAP ST and VPAP S devices are intended for use in the electromagnetic environment specified below. The customer or the user of the VPAP device should assure that the device is used in such an environment. Emissions test Compliance Electromagnetic environment - guidance RF emissions CISPR11 Group 1 The VPAP device uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. RF emissions CISPR 11 with serial adapter Class B The VPAP device is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage network that supplies buildings used for domestic purposes. RF emissions CISPR 11 with USB adapter Class B Harmonic Emissions IEC 61000-3-2 Class A Voltage Fluctuations/Flicker Emissions IEC 61000-3-3 Complies Warnings: The VPAP device should not be used adjacent to or stacked with other equipment. If adjacent or stacked use is necessary, the VPAP device should be observed to verify normal operation in the configuration in which it will be used. The use of accessories (eg, humidifiers) other than those specified in this manual is not recommended. They may result in increased emissions or decreased immunity of the VPAP device. Recommended separation distances between portable and mobile RF communications equipment and the VPAP series of devices The VPAP device is intended for use in an environment in which radiated RF disturbances are controlled. The customer or the user of the VPAP device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the VPAP device as recommended below, according to the maximum output power of the communications equipment. Sepa...

Эта инструкция также подходит к моделям:
Прочие персональные приборы - VPAP S (1.23 mb)
Прочие персональные приборы - VPAP AUTO 25 (1.23 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории