Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации Emerson, модель OXYMITTER 4000

Производитель: Emerson
Размер: 3.29 mb
Название файла: cbcf810d-c237-40c7-9e47-dd1490830ae8.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Based on its review, IARC classified crystalline silica as a group 2A carcinogen (probable human carcinogen). The OSHA permissible exposure limit (PEL for cristobalite is 0.05 mg/m3 (respirable dust). The ACGIH threshold limit value (TLV) for cristobalite is 0.05 mg/m3 (respirable dust) (ACGIH 1991-92). Use NIOSH or MSHA approved equipment when airborne exposure limits may be exceeded. The minimum respiratory protection recommended for given airborne fiber or cristobalite concentrations are: CONCENTRATION 0-1 fiber/cc or 0-0.05 mg/m3 cristobalite Optional disposable dust respirator (e.g. 3M 9970 (the OSHA PEL) or equivalent). Up to 5 fibers/cc or up to 10 times the Half face, air-purifying respirator equipped with high OSHA PEL for cristobalite efficiency particulate air (HEPA) filter cartridges (e.g. 3M 6000 series with 2040 filter or equivalent). Up to 25 fibers/cc or 50 times the OSHA Full face, air-purifying respirator with high efficiency PEL for cristobalite (2.5 mg/m3) particulate air (HEPA) filter cartridges (e.g. 3M 7800S with 7255 filters or equivalent) or powered air -purifying respirator (PARR) equipped with HEPA filter cartridges (e.g. 3M W3265S with W3267 filters or equivalent). Greater than 25 fibers/cc or 50 times the Full face, positive pressure supplied air respirator OSHA PEL for cristobalite (2.5 mg/m3) (e.g. 3M 7800S with W9435 hose & W3196 low pressure regulator kit connected to clean air supply or equivalent). If airborne fiber or cristobalite concentrations are not known, as minimum protection, use NIOSH/MSHA approved half face, air-purifying respirator with HEPA filter cartridges. Rosemount Analytical Inc. A Division of Emerson Process Management Instruction Manual IB-106-340 Rev. 3.0 Oxymitter 4000 December 2003 Insulation surface should be lightly sprayed with water before removal to suppress airborne dust. As water evaporates during removal, additional water should be sprayed on surfaces as needed. Only enough water should be sprayed to suppress dust so that water does not run onto the floor of the work area. To aid the wetting process, a surfactant can be used. After RCF removal is completed, dust-suppressing cleaning methods, such as wet sweeping or vacuuming, should be used to clean the work area. If dry vacuuming is used, the vacuum must be equipped with HEPA filter. Air blowing or dry sweeping should not be used. Dust-suppressing components can be used to clean up light dust. Product packaging may contain product residue. Do not reuse except to reship or return Ceramic Fiber products to the factory. Rosemount Analytical Inc. A Division of Emerson Process Management Instruction Manual IB-106-340 Rev. 3.0 December 2003 Oxymitter 4000 WHAT YOU NEED TO KNOW BEFORE INSTALLING AND WIRING A ROSEMOUNT OXYMITTER 4000 OXYGEN TRANSMITTER 1. What type of installation does your system require? Use the following drawings, Figure 1 and Figure 2, to identify which type of installation is required for your Oxymitter 4000 system. LINE VOLTAGE 4-20 mA CAL. GAS INSTR. AIR (REF. AIR) INTEGRAL SPS 4000 OPTION NOTE: SPS MAY BE INSTR. AIR (REF. AIR) MOUNTED REMOTELY. LINE VOLTAGE 4-20 mA OXYMITTER 4000 WITH REMOTE LINE VOLTAGE 4-20 mA LINE VOLTAGE CAL. GAS 1 CAL. GAS 2 INSTR. AIR (REF. AIR) 37260001 Figure 1. Installation Options – Oxymitter 4000 with Integral Electronics CAL. GAS 1 CAL. GAS 2 OXYMITTER 4000 OXYMITTER 4000 WITH IMPS 4000 OPTION IMPS 4000 LOGIC I/O CAL. GAS REF. AIR Rosemount Analytical Inc. A Division of Emerson Process Management Instruction Manual IB-106-340 Rev. 3.0 Oxymitter 4000 December 2003 OXYMITTER 4000 LINE VOLTAGE 4-20 mA CAL. GAS INSTR. AIR (REF. AIR) OXYMITTER 4000 REMOTE ELECTRONICS WITH INTEGRAL SPS OPTION INSTR. AIR (REF. AIR) LINE VOLTAGE 4-20 mA 37260049 INSTR. AIR (REF. AIR) CAL. GAS 1 CAL. GAS 2 OXYMITTER 4000 REMOTE ELECTRONICS WITH WALL-MOUNTED SPS OPTION LINE VOLTAGE LINE VOLTAGE 4-20 mA Figure 2. Installation Options – Oxymitter 4000 with Remote Electronics Rosemount Analytical Inc. A Division of Emerson Process Management Instruction Manual IB-106-340 Rev. 3.0 December 2003 Oxymitter 4000 CAN YOU USE THE FOLLOWING QUICK START GUIDE? Use this Quick Start Guide if ... 1. Your system requires an Oxymitter 4000 with or without the INTEGRAL SPS 4000 OPTION. Installation options for the Oxymitter 4000 are shown in Figure 1. 2. Your system does NOT require an IMPS 4000 OPTION installation. 3. Your system does NOT use a Remote Electronics as shown in Figure 2. 4. You are familiar with the installation requirements for the Oxymitter 4000 Oxygen Transmitter. You are familiar with the installation requirements for the Oxymitter 4000 Oxygen Transmitter with an integral SPS 4000. If you cannot use the Quick Start Guide, turn to Section 2, Installation, in this InstructionBulletin. Rosemount Analytical Inc. A Division of Emerson Process Management Instruction Manual IB-106-340 Rev. 3.0 Oxymitter 4000 December 2003 QUICK START GUIDE FOR OXYMITTER 4000 SYSTEMS Before using...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории