Производитель: HP
Размер: 184.29 kb
Название файла: 93036.pdf
|
Фрагмент инструкции
Specifically, it has not been manufactured to European CE standards and does not carry the European CE-mark. © CLEMCO INDUSTRIES CORP. One Cable Car Drive Washington, MO 63090 Phone (636) 239-4300 Fax (636) 239-0788 ® CLEMCO SUPPLIED AIR RESPIRATOR MODEL 60 HP O.M. 10533 MC FILE NUMBER: 690-0985 DATE OF ISSUE: 09/85 REVISION: K, 05/15/98 WARNING Do not proceed with these instructions until you have READ the orange cover of this MANUAL and YOU UNDERSTAND its content.* These WARNINGS are included for the health and safety of the operator and those in the immediate vicinity. *If you are using a Clemco Distributor Parts and Maintenance Guide refer to the orange warnings insert preceding the Index before continuing with the following instructions. APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 1 Clemco Industries Corp. Washington, Missouri USA (314) 239-0300 TYPE C AND CE CONTINUOUS FLOW SUPPLIED-AIR RESPIRATOR IS APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS: TC# PROTECTION 1 MODEL Components Alternates Cautions andLimitations 2 HelmetFlow RegulatorFlow RegulatorFlow RegulatorCont. Flow Conn.Hose 25 Ft.Hose 50 Ft.Hose 100 Ft. 19C-130 SA APL 1050604440044100441121422043970441504398 xxxxxxxxB C D E J N O S 1 PROTECTION SA-Supplied -air 2 CAUTIONS AND LIMITATIONS B-Not for use in atmospheres immediately dangerous to life or health. C-Do not exceed maximum use concentrations established by regulatory standards. D-Air-line respirators can be used only when the respirators are supplied with respirable air meeting the requirements of CGA G-7.1 Grade D or higher quality. E-Use only the pressure ranges and hose lengths specified in the user's instructions. J-Failure to properly use and maintain this product could result in injury or death. M-All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations. N-Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer. O-Refer to users instructions, and/or maintenance manuals for information on use and maintenance of these respirators. S-Special or critical users instructions, and/or specific use limitations apply. Refer to instruction manual before donning. 1.0 INTRODUCTION 1.1 Scope of manual 1.1.1 This manual covers setup, operation, maintenance, replacement parts, and important warnings for safe operation of the Clemco Apollo 60 HP Supplied-Air Respirator. 1.1.2 OSHA requires the employer to establish a comprehensive respiratory protection program per regulations 29 CFR 1910.134(a)(b) and 29 CFR 1926.103, to include the following: 1. Program coordination by a designated responsible individual. 2. Evaluation of each worker’s ability to perform the work while wearing a respirator. 3. Periodic training. 4. Periodic environmental monitoring. 5. Respirator-fit testing. 6. Maintenance, inspection cleaning, and storage of the respirators. 7. Selection of the proper NIOSH-approved respirator. 1.1.3 For safe use of the respirator, it is essential that the user be properly instructed in its use and maintenance. This manual must be made available to all users of the respirator. [Reference OSHA Regulations 1910.134.] Read the entire manual before installing or operating the equipment. 1.1.4 The respirator must be supplied with respirable air meeting requirements described herein. It is the responsibility of the owner to provide quality breathing-air to the respirator, and to establish a program to ensure that the respirator is properly used and maintained. 1.1.5 The following manuals are available for accessories that may be used in conjunction with the Apollo Respirator. Description Manual No. CAT Cool-Air Tube 08956 CCT Climate Control Tube 08850 CPF Particulate Air Filter 04143 ABL 4021 CarbonMonoxide Alarm 21457 1.2 Hazard Alerts 1.2.1 Clemco uses signal words, based on ANSI Z535.21991, to alert the user of a potentially hazardous situation that may be encountered while operating this equipment. ANSI’s definitions of the signal words are as follows: ! NOTICE “Notice” is used to indicate a statement of company policy as the message relates directly or indirectly to the safety of personnel or protection of property. ! CAUTION “Caution” is used to indicate a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 2 ! WARNING “Warning” is used to indicate a potentially hazardous situation which, if not avoided, could result in death or serious injury. ! DANGER “Danger” is used to indicate an imminently hazardous situation which, if not avoided, will result in death or serious injury. 1.3 Respiratory and Health Alerts ! WARNING TOXIC DUST POISONING Research by the Occupational Safety and Health Administration (OSHA) has discovered potential risks of lead and other heavy metal poisoning to unprotected abrasive blasting operators and other personnel who may be expo...
Эта инструкция также подходит к моделям:Прочие персональные приборы - Clemco 60 HP (184.29 kb)