Войти:
Оценок - 1, средний балл: 3 ( )

Инструкция по эксплуатации Aero Mist, модель Professional Misting System 52500

Производитель: Aero Mist
Размер: 294.75 kb
Название файла: 3e3b81a6-0ffc-4998-ba46-0468efbc6532.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Complete seal with one wrench turn of fitting. Use Vinyl-Coated Clamps, Screws And Anchors (52509) to secure nylon tubing and filter to the side of the struc- ture. Use Brass Union (52510) to connect additional tubing. 3. Use Brass Elbow (52511) to connect Pre-Fabricated Misting Line (52519) to Flexible Nylon Tube (52516), secure Pre-Fabricated Misting Line (52519) to the bottom outside edge of fascia, header or beam with Vinyl-Coated Clamps, Screws And Anchors (52509). If necessary, cut the Pre-Fabricated Misting Line (52519) with a tubing cutter. Never use a saw to cut copper tubing, this will leave burrs and pre- vent the compression joints from sliding over the tubing. Space clamps on Pre-Fabricated Misting Line (52519) 24" apart. Use Brass Union (52510) to join sections of Pre-Fabricated Misting Line (52519). Terminate system with Brass End Plug (52513). 4. Connect garden hose to inlet of Sediment Filter (52505) and flush sys- tem for several minutes before inserting nozzles. While system is flushing start inserting the .014 Misting Nozzles (52502) nozzles nearest the filter first. Shut water off to insert last nozzle. Caution: hand-tighten only. Never use pliers to tighten nozzles. MAINTENANCE • When turning the misting system off, it is beneficial to drain the water out of the line by disconnecting the garden hose at the filter. This will help eliminate mineral buildup. • Nozzles require cleaning or replacement periodically. Clean nozzles by soaking in vinegar or calcium removal product overnight. • Replace filter annually, water conditions may require replacement sooner. • Winterize your misting system by removing all nozzles. Be sure all water is drained from misting lines. This will prevent water from freezing and damaging the mist line. For summer season start-up, follow Step 4 in the Installation Instructions. Note: Misting system is intended for outdoor use only. INSTALLATION INSTRUCTIONS ........................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................ LIST OF ALL ENCLOSED PARTS QTY PART NO DESCRIPTION 1 52505 Sediment Filter 2 52519 Pre-Fabricated Misting Line (6' section) 2 52516 Flexible Nylon Tube (6' section) 6 52502 .014 Misting Nozzle 1 52511 Brass Elbow 2 52510 Brass Union 1 52513 Brass End Plug 10 52509 Vinyl-Coated Clamp, Screw and Anchor TOOLS REQUIRED Tape Measure Screwdriver Power Drill with 1/4" Bit (if using anchors) Tubing Cutter (if customizing length) 5/8" Open-End Wrench 9/16" Open-End Wrench 1. Start by measuring the length of your patio perimeter (or perimeter of the area to be misted). Proper installation of your new Aeromist Professional Misting System requires mounting the Pre-Fabricated Misting Line (52519) on the bottom outside edge of the fascia, header or beam of patio perimeter. It is important to mount the line along the bottom edge, to prevent mist from spraying on structure. This installation will create a curtain of mist around your patio or misted area and provide maximum cooling. The Aeromist Extension Kit (52501) extends your system by 6 ft. Add multiple extension kits to custom fit a misting system to your patio or misted area mist up to 150 ft (more with optional pump). See the enclosed ac- cessories brochure or go to for a sample of additional accessories and upgrades available including high-pressure pumps for in- creasing your misting system’s cooling performance and length. 2. Start installation by connecting Flexible Nylon Tube (52516) to outlet compression fitting on the Sediment Filter (52505). Finger tighten brass fitting, then insert tubing until it bottoms out in fitting. Complete seal with one wrench turn of fitting. Use Vinyl-Coated Clamps, Screws And Anchors (52509) to secure nylon tubing and filter to the side of the struc- ture. Use Brass Union (52510) to connect additional tubing. 3. Use Brass Elbow (52511) to connect Pre-Fabricated Misting Line (52519) to Flexible Nylon Tube (52516), secure Pre-Fabricated Misting Line (52519) to the bottom outside edge of fascia, header or beam with Vinyl-Coated Clamps, Screws And Anchors (52509). If necessary, cut the Pre-Fabricated Misting Line (52519) with a tubing cutter. Never use a saw to cut copper tubing, this will leave burrs and pre- vent the compression joints from sliding over the tubing. Space clamps on Pre-Fabricated Misting Line (52519) 24" apart. Use Brass Union (52510) to join sections of Pre-Fabricated Misting Line (52519). Terminate system with Brass End Plug (52513). 4. Connect garden hose to inlet of Sediment Filter (52505) and flush sys- tem for several...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории