Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Brinkmann, модель MAXFIRE 800-2200-0

Производитель: Brinkmann
Размер: 184.6 kb
Название файла: 800-2200-0.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• A damaged battery can leak acid. Avoid contact with eyes and skin. If contact occurs, flush immediately with large amounts of water. DO NOT ingest. If contact with eyes or ingestion occurs, consult physician immediately. USE CAUTION AND COMMON SENSE WHEN OPERATING YOUR SPOTLIGHT. FAILURE TO ADHERE TO THE SAFETY WARNINGS AND GUIDELINES IN THIS MANUAL COULD RESULT IN BODILY INJURY OR PROPERTY DAMAGE. SAVE THIS MANUAL FOR FUTURE REFERENCE. INSTR-800-2200-0_Dual Xenon.qxd 6/24/03 3:23 PM Page 3 OPERATING INSTRUCTIONS READ AND FOLLOW ALL SAFETY WARNINGS AND INSTRUCTIONS IN THE OWNER’S MANUAL BEFORE OPERATING SPOTLIGHT. Inspect contents of the box to ensure all parts are included and undamaged. 1 2 3 Step 1: Depress trigger switch in handle to turn spotlight ON. Step 2: Release trigger switch to turn spotlight OFF. Continuous Beam Using Lock Button: Step 1: For a continuous beam, depress trigger switch and slide the lock button to the LOCKED position. Step 2: To unlock and turn spotlight OFF, slide the lock button to the UNLOCKED position. NOTE: To lock the Dual Xenon in the OFF position, release trigger switch, then slide the lock button to the LOCKED position. WARNING: Always turn spotlight off when not in use. Switching Between Single and Dual Beams: Step 1: For single beam, slide switch on back of light to one dot, as illustrated. Step 2: For dual beam, slide switch on back of light to two dots, as illustrated. NOTE: The Dual Xenon will burn for approximately 40 minutes if using both beams, or approximately 85 minutes if using only one beam. Step 1: Make sure trigger switch is not locked in the ON position. Step 2: Plug the AC charger or DC charger/adapter into the socket located on the base of the spotlight handle as illustrated. Step 3: For DC Charger/Adapter: Plug the other end of the DC charger/adapter into a cigarette lighter receptacle. For AC Charger: Plug the other end of the AC charger into a wall outlet. 2 Dual Xenon spotlight 120-volt AC charger 12-volt DC charger/adapter lighter plug Parts List 1 2 3 Owner’s Manual To Operate Beam Trigger Switch Switch Button Lock Unlocked Single Locked Beam Dual Beam To Charge LED Indicator INSTR-800-2200-0_Dual Xenon.qxd 6/24/03 3:23 PM Page 4 IMPORTANT: The EPA Certified RBRC® Battery Recycling Seal on the lead acid (Pb) battery contained in our product indicates The Brinkmann Corporation is voluntarily participating in an industry program to collect and recycle these batteries at the end of their useful life, when taken out of service in the United States or Canada. The RBRC® program provides a convenient alternative to placing Step 4: Allow the spotlight to charge for at least 8 hours. Do not allow to charge more than 12 hours. Note: LED indicator on base of handle turns off automatically when battery is fully charged. Step 5: Remove spotlight from the charger before operating. See chart for recommended charge times. Charge Times Charge time is dependent on usage of the product. See chart below for recommended charge time. 85 Battery Charge 4 812 used Pb batteries into the trash or the municipal waste stream, which may be illegal in your area. Please call 1-800-8-BATTERY™ for information on Pb battery recycling and disposal bans/restrictions in your area. The Brinkmann Corporation’s involvement in this program is part of our commitment to preserving our environment and conserving our natural resources. USAGE (Minutes) 40 CHARGE TIME (Hours) Only use Brinkmann xenon bulb that is designed for the Dual Xenon To Replace Bulb spotlight as a replacement. Use of any other bulb may result in poor performance and may damage your spotlight. NOTE: Handling the bulb can leave oil from your fingers on the bulb. To extend the life of the new bulb and maximize brightness, gently clean off bulb with soft cloth or tissue. Make sure the reflector does not touch or bend the bulb while replacing spotlight head. Step 1: Disconnect spotlight from charger. Step 2: Remove front rubber cap from barrel of spotlight. Step 3: Pinch the wings of the glass retainer together and lift as illustrated. Glass & Reflector Rear Housing Glass Rubber Retainer Cap Step 4: Pull glass and reflector away from rear housing. Step 5: Pull old bulb straight out of bulb holder. Step 6: Make certain that "legs" on new bulb are straight. Insert "legs" into the two holes in the bulb holder. Step 7: Gently push bulb straight in until fully seated and centered. Step 8: To reassemble, place the glass and reflector on the rear housing. Insert the glass retainer into the rear housing. Step 9: Replace rubber cap. WARNING: Do not touch the lamps when light is on or if it was recently on. The lamps will be hot and could cause serious burns. 3 INSTR-800-2200-0_Dual Xenon.qxd 6/24/03 3:23 PM Page 1 To Hang/Store Dual Xenon Tips to Avoid Damage to Your Dual Xenon Spotlight The retractable hanging ring allows spotlight to hang while in use or during storage. • Never attempt to wipe or clean the inner reflective surface...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории