Войти:
Оценок - 1, средний балл: 3 ( )

Инструкция по эксплуатации Cooper Lighting, модель CMS185, CMS185W

Производитель: Cooper Lighting
Размер: 161.82 kb
Название файла: bae9f286-d856-4c3c-82de-b15ffe48922b.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


325-1417 1/7/04 3:59 PM Page 2 Congratulations. You have purchased a Regent motion activated floodlight. This security lighting system will provide years of convenience and protection for your home and family. How it works Your Regent motion activated floodlight senses heat images from objects such as people, large animals and automobile engines. When motion is detected, the lights will automatically turn on. Once motion has stopped, the lights will turn off after a preselected time delay. Your motion activated floodlight may also be used as a stan- dard floodlight. What you need •Phillips screwdriver •Outdoor weatherproof silicone caulking •(2) 150 Watt (max) PAR 38 floodlight bulbs (A) What’s included •Motion detector and light fixture (B) •Coverplate gasket (C) •(2) Lampholder gaskets (D) •(4) Mounting bracket screws (E) •(3) Wire nuts (F) •Color matched center hole plug (G) •Center bolt (H) •Mounting bracket (I) What to know •For outdoor use only. •UL and cUL LISTED for wet locations. • This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Under Part 15 of the FCC Rules, any changes or modifications to the motion detector described in this instruction sheet that are not expressly approved by Cooper Lighting could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inter- ference in a residential installation. This equipment generates, uses and can radi- ate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encour- aged to try to correct the interference by one or more of the following measures: 2 ENGLISHMS185, CMS185 (Bronze) MS185W, CMS185W (White) 70 foot 180 degrees A B C D E F G H I • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. •Fixture must be connected to a 120 Volt, 60 Hz 2.5, 300 watt power source. Any other connection voids warranty. •This motion activated twin floodlight should be installed by persons with experi- ence in household wiring or by a qualified electrician. The electrical system, and the method of electrically connecting the fixture to it, must be in accordance with the National Electrical Code and local building codes. •For proper operation and protection against damage, the motion sensor head adjustment knobs must be facing the ground. •Disassembly of your fixture will void the warranty. For best results •Install your fixture 8-12 feet above ground (motion detector is less sensitive above 12 feet). •Locate fixture so motion moves across detection zone (J). •Locate fixture away from heat producing sources to prevent false triggering. Also be very careful not to include objects such as windows, white walls and water in the detection zone whenever possible. •Locate fixture away from moving objects such as trees and street traffic. •Do not install more than one motion activated floodlight on one wall switch. Mounting your fixture Step 1: Turn off the power at the main fuse/breaker box. Check to make sure power has been disconnected before continuing. Step 2: Line up the holes on the mounting brack- et with the holes on your junction box. Using either (2) #6 screws or (2) #8 screws (depending on size of the holes in your junction box), attach the mounting bracket to your junction box (K). Step 3: Thread fixture wires through coverplate gasket. Step 4: Connect black wire to house black wire and con- nect white wire to house white wire using wire nuts provided. Step 5: Attach fixture to the junction box with two screws provided. Step 6: Attach fixture to the mounting bracket using the center bolt provided. Insert plastic color matched plug in center bolt hole for finished appear- ance. Step 7: Apply silicone caulking around edges of coverplate and in any open holes to provide a watertight seal from rain and moisture. Step 8: Insert gaskets into lampholder assembly, tight- ly against lampholder and screw bulbs into each lampholder. (Do not overtighten bulbs). Step 9: Turn power on at main fuse/breaker box. ENGLISH 3 J Round Rectangular (horizontal) Octagonal Your fixture mounts to t...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории