Войти:
Оценок - 3, средний балл: 4.7 ( )

Инструкция по эксплуатации Cal Spas, модель GFCI

Производитель: Cal Spas
Размер: 8.96 mb
Название файла: 2008_09_19_manuals_spa_portable_us.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


ST Indicates heater is in standard mode. Ec Indicates heater is in economy mode. SL Indicates heater is in sleep mode. 9800 Electronic Control Operation When first powered up, the 9800 electronic system will perform a self-diagnostic check and then it will automatically heat to and maintain a temperature of 100°F (37.5°C) until you change the set temperature as listed in the “Temperature Adjustment” section below. These instructions will describe features and options that your particular spa may not be equipped with. Initial Start-up When your spa is first powered up, it displays some configuration codes and then goes into priming mode (Pr will appear on the display panel). This mode lasts up to four minutes and then the spa begins to heat to its pre -programmed temperature of 100°F. Temperature Adjustment (Range 80°F to 104°F, 26°C to 40°C) The start-up temperature is set at 100°F (37.5°C). The last measured temperature is constantly displayed on the control panel. Note that the last measured spa temperature is displayed. The displayed temperature will be updated when the pump has been running for at least two minutes. Press the “UP” or “DOWN” buttons once to display the set temperature. Each time either button is pressed again, the set temperature will increase or decrease depending on which button is pressed. After three seconds, the control panel will automatically display the last measured spa temperature. Time When time hasn’t been programmed, the “TIME” icon flashes. To set the time, press the “TIME” button and then the “MODE/PROG” button. Use the “UP” and “DOWN” buttons to adjust time. See the next page for more detailed instructions. Standard, Economy, Sleep, and Standby Modes Mode/Prog: This button is used to switch between standard, economy, and sleep modes. Press “MODE/PROG” to enter mode programming.1. Press the “DOWN” button to cycle through to the 2. desired mode. Press “MODE/PROG” to confirm selection.3. Standard Mode: This is programmed to maintain the desired temperature. Note that the last measured spa temperature displayed is current only when the pump has been running for at least two minutes. The “STAND” icon will display until the mode is changed. Economy Mode: Economy mode heats the spa to the set temperature only during filter cycles. The “ECON” icon will display until the mode is changed. Pressing the “JETS 1” button while in economy mode puts the spa in standard-in-economy mode, which operates the same as standard mode but reverts back to economy mode automatically after one hour. During this time, pressing the “MODE/PROG” button will revert to economy mode immediately. Sleep Mode: Sleep mode heats the spa to within 20°F (11°C) of the set temperature only during filter cycles. The “SLEEP” icon will display until the mode is changed. Standby Mode: Pressing “Warm” or “Cool” then “JETS 2” will turn off all spa functions temporarily. This is helpful when changing a filter. Pressing any button resets the spa. Jets 1 Press the “JETS 1” button once to turn pump 1 on or off and to shift between low and high speeds if equipped. If left running, the low speed turns off after two hours and the high speed turns off after 15 minutes. On non- circulation systems, the low speed of pump 1 runs when the blower or any other pump is on. It may also activate for at least two minutes every 30 minutes to detect the spa temperature and then to heat to the set temperature if needed, depending upon the mode. When the low speed turns on automatically, it cannot be deactivated from the panel; however, the high speed may be started. Jets 2 Press the “JETS 2” button once to turn pump 2 on or off and to shift between low and high speeds if it is a two- speed pump. If left running, the pump will turn off after 15 minutes. Option This is an optional feature. Press the “OPTION” button to turn the optional equipment on and off. If left on, the equipment will automatically turn off after 15 minutes. Light Press the “LIGHT” button to turn the spa light on and off and to shift between dim and bright settings if your light is dimmable. On dim, the control panel will show the center circle plus one quarter of the light beams. Half of the light beams will show on medium brightness, and all of the light beams will show on bright. Invert Press the “INVERT” button to change the numbers in the display to read upside down. Another press returns the display to the right-side-up position. This enables you to read the display while you are in the spa. Locking the Panel To lock the panel: Press “TIME”, “JETS 1”, and the “UP” button within • three seconds. When locked, the panel will display “LOCK”. All buttons are frozen except the “TIME” button. To unlock the panel: Press “TIME”, “JETS 1” then the “DOWN” button • within three seconds. Setting the Temperature Lock To activate the temperature lock: Press the “UP” or “DOWN” button, “TIME”, “JETS 1”, • then the “UP” button within three seconds. The panel will display “TEMP LOCK” wh...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории