6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max. Note: Vertical (V1) + Vertical (V2) = 20' max. Figure 30 - Vertical Rigid Venting Configuration Using Two 90° Elbows 14 106573 OWNER’S MANUAL VENTING INSTALLATION Continued HIGH ALTITUDE INSTALLATION Your Vanguard direct-vent fireplace has been AGA tested and approved for elevations from 0-2000 feet and CGA certified for elevations from 0-4500 feet. When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification. When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities. Consult your local gas company to help determine the proper orifice for your location. For assistance with any high altitude installation contact DESA International’s Technical Service Department at 1-800-DESALOG (1-800-337-2564). PARTS LISTS FOR VENTING KITS AND COMPONENTS *NOTICE: The 7" x 30° Elbow supplied with kits CVK, BVK, SVK, and RVF cannot be used. It MUST be replaced with a 7" x 45. Starter Elbow (D2060). Vanguard Rigid Venting Number Description *CVK Corner Vent Kit Includes: 7" x 30. Elbow, 7" x 90. Elbow, 7" Adjustable Galvanized Pipe (7-12"), 6" Pipe, Wall Thimble, Horizontal Termination, RTV Silicone and 20 Screws *BVK Basement Rigid Vent Kit Includes: 7" x 30° Elbow, 7" x 4' Galvanized Pipe, 7" x 90° Elbow, 7" Adjustable Galvanized Pipe (7-12"), Wall Thimble, Horizontal Termination, RTV Silicone and 20 Screws Vanguard Rigid Venting (Cont.) Number Description *SVK Snorkel Rigid Vent Kit Includes: 7" x 30° Elbow, 7" x 4' Galvanized Pipe, 7" x 90° Elbow, 7" Adjustable Galvanized Pipe (7-12"), Wall Thimble, 36" Snorkel Termination, RTV Silicone and 28 Screws *RVF Roof Rigid Vent Kit Includes: Flue Restrictor, Storm Collar, 7" x 30° Elbow, 7" x 4' Galvanized Pipe, 7" x 2' Galvanized Pipe, 7" Adjustable Galvanized Pipe (7-12"), Firestop Support, Roof Flashing, RTV Silicone, Vertical Termination, and 26 screws D1000 7" x 12" Galvanized Coaxial Pipe (6 pcs.) D1010 7" x 24" Galvanized Coaxial Pipe (6 pcs.) D1020 7" x 48" Galvanized Coaxial Pipe (6 pcs.) D1030 7" Adjustable (7-12") Galvanized Coaxial Pipe (6 pcs.) D1050 7" x 6" Galvanized Coaxial Pipe (6 pcs.) D2000 7" x 90° Elbow (6 pcs.) D2010 7" x 45° Elbow (6 pcs.) D2060 7" x 45° Starter Elbow D3000 Wall Strap/Offset Support (6 pcs.) D3010 Storm Collar (6 pcs.) D3020 Wall Thimble (6 pcs.) D3050 Vertical Restrictor (6 pcs.) D3060 Ceiling Firestop/Support (6 pcs.) D3070 Rectangular Horizontal Rigid Vent Termination Cap D3071 Adjustable Horizontal Rigid Vent Termination Cap D3090 Cathedral Ceiling Support Box D4000 Roof Flashing 6/12-9/12 D4010 Roof Flashing 9/12-12/12 D4020 Flex Connector (6 pcs.) D4030 Flex Wall Thimble (6 pcs.) D4040 4" Hose Clamp (6 pcs.) D4050 7" Hose Clamp (6 pcs.) D5000 Vinyl Siding Standoff (6 pcs.) Vanguard Flexible Venting Number Description FGFVK Flex Ground Floor Vent Kit Includes: Flex Adapter, 7" x 4' Flexible Pipe, 4" x 4' Flexible Pipe, Wall Thimble, Horizontal Termination, (4) Spacer Springs, (2) 4" Hose Clamps, (2) 7" Hose Clamps, RTV Silicone, and 10 Screws D1040 7" x 25' Coaxial Flex Pipe with Spacer Springs D3080 Rectangular Horizontal Flex Termination Cap SIMPSON DURA-VENT GS 4" x 6 5/8 " Number Description 902 7" x 48" Pipe 903 7" x 36" Pipe 904 7" x 24" Pipe 906 7" x 12" Pipe 907 7" x 9" Pipe 908 7" x 6" Pipe 911 7" Adjustable (11"-14 5/8") Pipe 940 Wall Thimble 941 Cathedral Ceiling Support Box 943 Roof Flashing 0/12-6/12 943S Roof Flashing 7/12-12/12 945 7" x 45° Elbow 950 Vinyl Siding Standoff 953 Storm Collar 963 Ceiling Firestop 981 36" Snorkel Termination 984 Horizontal Termination Vent Cap 988 Wall Strap 990 7" x 90° Elbow 991 Vertical High Wind Termination 106573 15 16 106573 DIRECT-VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN ® INSTALLATION INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2 NOTICE: The GWMS2 includes 25' of wire for installation. Your fireplace includes 15' of wire for accessory installation. Choose the length that best fits your needs when installing this accessory. The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off. The wall switch is to be connected to the incoming 120 volt regular household wiring that supplies electricity to the fireplace. Refer to wiring diagram on page 22. For Optional Fan Kit From Blower Assembly CAUTION: Due to high temperatures, make sure no wires are touching the bottom of the firebox. OPTIONAL BLOWER ASSEMBLY INSTALLATION Before blower assembly can be operated, it must be properly connected to a standard 120 VAC power source. Refer to Wiring Diagram on page 22. 1. To remove lower louver, pull both top spring latches toward the center of the appliance at the same time until they are disengaged fr...

Эта инструкция также подходит к моделям:
Прочие аксессуары для дома - EVDDVF36PN (683.8 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории