|
Фрагмент инструкции
If damaged, promptly inform dealer or distributor where you bought the product. Safely retain these items for later installation. For more information, visit more information, visit 108796-01E 4 4 INTRODUCTION Before You Begin INTRODUCTION Models M36E(B,H), VM36E(B,H), M42E(B,H) and VM42E(B,H) are vented gas fireplaces that use an electronic gas control valve and electronic ignition system. A 6" B-Type venting system and a listed type vent cap are not supplied but are required for proper operation. See venting instructions on pages 9 and 10. WARNING: This gas appliance must not be connected to a chimney flue servicing a solid fuel burning appliance. Models M36E(B,H), VM36E(B,H), M42E(B,H) and VM42E(B,H) are factory equipped for use with natural gas and must be converted when intended for use with propane/LP gas. A respective model PCBE-36 or PCBE-42 conversion kit may be purchased for simple conversion to propane/LP gas. See Accessories, page 27. BEFORE YOU BEGIN Before beginning the installation of your appliance, read these instructions through completely. This DESA appliance and its approved components are safe when installed according to this installation manual and are operated as recommended by DESA. Unless you use DESA approved components tested for this appliance, YOU MAY CAUSE A FIRE HAZARD! The DESA warranty will be voided by, and DESA disclaims any responsibility for the following actions : A) Modification of the appliance or any of the components. B) Use of any component part not approved by DESA in combination with this appliance. C) Installation and/or operation in a manner other than instructed in this manual. D) The burning of anything other than the type of gas approved for use in this gas appliance. The installation must conform with local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1 or with the current CAN/CGA B149 Installation Codes. This appliance complies with ANSI Z21.50-2000 and CSA 2.222000 as Vented Gas Fireplaces and is listed and tested by the Canadian Standards Association to the above test standards. WARNING: Installationof this appliance should be done by a qualified service person well trained in the installation of such appliances. You will also need a building permit from your local Building and Safety Commissioner before installing this appliance; otherwise your insurance co. may not cover this appliance. The appliance and it’s individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). For the purpose of input adjustment two pressure taps (for IN and OUT pressures) are provided on the gas control valve for test gauge connections to the appliance. NOTICE: This appliance is not intended to be used as a primary source of heat. CAUTION: Do not connect appliance before pressure testing gas piping. Damage to gas valve may result and an unsafe condition may be caused. GAS RATING - NATURAL M36E(B,H)/VM36E(B,H) M42E(B,H)/VM42E(B,H) Max. Input Rating: 40,000 Btu/Hr 45,000 Btu/Hr Manifold Pressure: 3.5 in. WC (.87 kPa) 3.5 in. WC (.87 kPa) Minimum Supply Pressure: 4.5 in. WC (1.12 kPa) 4.5 in. WC (1.12 kPa) Maximum Supply Pressure: 10.5 in. WC (2.66 kPa) 10.5 in. WC (2.66 kPa) Orifice Size: # 30 # 29 GAS RATING - PROPANE/LP Max. Input Rating: 40,000 Btu/Hr 45,000 Btu/Hr Manifold Pressure: 10.0 in. WC (2.49 kPa) 10.0 in. WC (2.49 kPa) Minimum Supply Pressure: 11.0 in. WC (2.74 kPa) 11.0 in. WC (2.74 kPa) Maximum Supply Pressure: 13.0 in. WC (3.23 kPa) 13.0 in. WC (3.23 kPa) Orifice Size: # 52 # 50 For more information, visit more information, visit 108796-01E PRODUCT SPECIFICATIONS 5 PRODUCT SPECIFICATIONS S T P Q R X Outside Air Kit Location (Optional) K 7" J I M L V 13.5" 1.5"Glass Door (Optional) W ON Alternate Gas Supply Inlet 7" G H FA Stand Off Collar For Use With 6"O Type B-1 Vent Pipe Only B E D C DIMENSIONS HEARTH AREA 7" Model 36 Model 42 Model 36 Model 42 A B C D E F G H I J K L 29" 5/8" 41" 12" 21 1/4" 22 1/4" (24" w/o Brick) 32 5/8" (34" w/o Brick) 15 3/4" (16 3/4" w/o Brick) 40 1/4" 21" 8" 34 3/4" 36" 5/8" 48" 14" 23" 29 1/4" (31" w/o Brick) 39 1/2" (41 1/4" w/o Brick) 17 3/4" (18 3/4" w/o Brick) 44 1/4" 24" 9" 42" M N O P Q R S T U V W X 42" 36" 37" 8 5/8" 13 7/8" 10 1/2" 2 1/2" 8 1/8" 11" 7" 2 1/4" 5" 49" 40" 41" 10 1/2" 14" 12 1/2" 2 1/2" 8 1/8" 12 3/4" 7" 2 1/4" 4 1/2" Figure 1 - Appliance Dimensions For more information, visit more information, visit 108796-01E 108796-01E 6 Forr morre iinfforrmattiion,, viisiitt CLEARANCES Minimum clearances to comb...
Эта инструкция также подходит к моделям:Прочие аксессуары для дома - M36E(B (3.11 mb)
Прочие аксессуары для дома - M42E(B (3.11 mb)
Прочие аксессуары для дома - VM42E(B (3.11 mb)