Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации Emerson, модель LK59FSST

Производитель: Emerson
Размер: 91.88 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Hold the glass shade(1) securely while removing the finial nut(2), glass cap(3), hex nut and the guide plate(4) (Figure 7). 3. Carefully place the glass shade, finial nut, glass cap, hex nut and guide plate in a safe place while replacing the bulb(s). NOTE: Use only replacement 13-watt GU24 fluorescent bulb(s). 4. Install the replacement bulb in accordance with the “Installation of Fluorescent Bulbs and Glass Shade” section, on Page 5. 6 Installation Fans with (Detachable) Switch Cups 1. Remove all parts and parts from the carton. 2. On the ceiling fan, remove the switch cup(1) from the cover plate(2) by removing the three screws(3) around the side of the switch cup (Figure 1). 3. Disconnect the motor connector(4) from the switch cup connector(5) (Figure 1). 4. Remove the center screw(6) from the switch cup (Figure 1). 5. Carefully locate the white and blue wires (labeled either "L" or "LIGHT") in the switch cup. Remove and retain the wire connectors(6) from the wires (Figure 2). 6. Insert the black and white wires from the light fitter(7) through the center hole in the switch cup (Figure 2) and thread the switch cup tightly onto the light fitter. Hold wires taut while installing switch cup to prevent the wires from twisting. (3) SCREWS (6) CENTER SCREW (1) SWITCH CUP (4) MOTOR CONNECTOR (2) COVER PLATE (5) SWITCH CUP CONNECTOR Figure 1 7. Insert the black the lockwasher(supplied. Firmly tighten secure the light kit fitter(cup(1) (Figure 2). 8. Connect the white wire from cup to the white wire of the light (Figure 2). Connect the blue wire the switch cup to the black wire of the light fitter. Use U.L. listed wire connectors (previously removed in Step 5) to make connections (Figures 2 and 3). (3) SCREWS (5) SWITCH CUP CONNECTOR (2) COVER PLATE (6) WIRE CONNECTORS WHITE WIRES (1) SWITCH CUP BLACK WIRE FAN SWITCH CHAIN (8) LOCKWASHER (9) HEX NUT (7) LIGHT FITTER BLUE WIRE (4) MOTOR CONNECTOR Figure 2 WARNING ! To avoid possible fire or electrical shock, make certain no bare wire strands are exposed outside wire connectors. Figure 3 9. Carefully tuck all wires and splices into the switch cup(1). (Figure 2.) 10. Connect the motor connector(4) to the switch cup connector(5). 3 11. Position the the cover plate(three screws(3) that removed in Step 2 and securely. WARNING ! To avoid possible fire or electric be careful not to pinch wires between switch cup and the cover plate. 12. Proceed to “Installation of Fluorescent Bulbs and Glass Shade” section. Installation on Emerson Fans Having Two-Piece Die-Cast Switch Housings 1. Remove all parts and parts packages from carton. WARNING ! To avoid possible electric shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. 2. Remove the cover(5) from the fan switch housing(1) by removing the two outer screws(2). (See Figure 4). 3. Remove the center screw(4) from the cover(5). Insert the black and white wires from the light fitter(6) thru the hole and thread the switch housing cover tightly onto the light fitter. 4. Insert the black and white wires through the lockwasher(8) and hex nut(7) supplied. Firmly tighten the hex nut to secure the light fitter to the switch housing cover(5). WHITE WIRES BLUE WIRE BLACK WIRE ASSEMBLY (8) LOCKWASHER (7) HEX NUT (6) LIGHT FITTER FAN SWITCH (1) SWITCH CHAIN HOUSING (3) WIRE CONNECTORS (5) COVER (4) CENTER SCREW (2) SCREWS Figure 4 5. Carefully locate the white and blue wires (labeled either “L” or “LIGHT”) in the switch housing. Remove and retain the wire connectors(3) from the wires. 6. Connect the white wire from the ceiling fan to the white wire of the light fitter(6). Connect the blue wire from the ceiling fan to the black wire of the light fitter. Use U.L. listed wire connectors(3) (previously removed in Step 5) to make connections. (Figures 3 and 4.) 7. Carefully tuck all wires and splices into the switch housing(1). 8. Attach the cover/light fitter(5)(6) to the switch assembly housing(1) using the two outer screws(2) that were removed in Step 2) (Figure 4.) WARNING ! To avoid fire or electrical shock, be careful not to pinch wires between the switch housing assembly and the cover. 9. Proceed to “Installation of Fluorescent Bulbs and Glass Shade” section. 4 Installation Fluorescent Bulbs Glass Shade WARNING ! To avoid fire hazard, do not wattage indicated on the fixture. 1. Carefully position one of the GU24 fluorescent bulbs(1) (supplied) into the light fitter socket. Twist the bulb clockwise, approximately 1/16 turn, to engage the bulbs pins into the light fitter socket holes(2) (Figure 5). Install the remaining three GU24 fluorescent bulbs in the same manner. 2. Remove the fan switch pendant(3) from the fan switch chain(4) for installation of glass. Place the fan switch chain through the light fitter plate(5) hole (Figure 5). (1) 13-WATT GU24 FLUORESCENT BULB (4) (2) LIGHT FITTER SOCKET (5) LIGHT FITTER PLATE HOLES (4) FAN SWITCH CHAIN (3) FAN SWITCH PENDANT LIGHT FITTER PLATE Figure 5 3. P...

Эта инструкция также подходит к моделям:
Прочие аксессуары для дома - LK59FOM (91.88 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории