Войти:
Оценок - 3, средний балл: 4.7 ( )

Инструкция по эксплуатации Monessen Hearth, модель ODGR500

Производитель: Monessen Hearth
Размер: 1.38 mb
Название файла: c5f8374f-5ff1-4140-bd0d-e758f23cd2b1.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


(Fig. 5) 2. Lift the brick with the logo on it. (Fig. 6) Hard, Flat Surface (i.e. concrete) FP1642a Fig. 7 Exterior chase installation. FP1416ODUVSRpart id11/24/03 djt Gas Line Installation This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure equal to or less than 1/2 psig (3.45 kPa). The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPa). If gas piping from the source to the appliance location has not been accomplished, install the required pipe. Consult local plumbing code to assure proper pipe size. The gas pipeline can be brought in through the right side of the appliance. A knockout is provided to allow for the gas pipe installation and testing of any gas connection. NOTE: The gas line connection can be made with 3/8" copper tubing approved for propane or natural gas, 1/2" rigid pipe or an approved flex connector, then reduced to 3/8" to the appliance. Because some municipalities have some additional local codes, it is always best to consult your local authority. U.S.: Consult the current National Fuel Gas Code, ANSI Z223.1/NFPA 54. Canada: CSA - B149.1 installation code. Test for leaks. Use a 50/50 solution of liquid soap and water to test for leaks at gas fittings and joints. Apply water/soap solution with brush only - do not over apply. NEVER test with an open flame. The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to provide a 1/8" test point up stream of the control. When using copper or flex connector use only approved fittings. Always provide a union so that gas line can be easily disconnected for burner or fan servicing. See gas specification for pressure details and ratings. NOTE: If flex connector is used, it must be kept inside of the appliance. (Fig. 10) *Do not install header until unit is in place. Standoff Surround Gas Line Access Nailing Flange Screen Grate Firebox Valve Access Panel FP1416 Fig. 8 Parts identification. FP1416ODUVSRpart id11/24/03 djt Interior sides of an exterior chase should be weather proof *Do not install header until unit is in place. Standoff Surround Gas Line Access Screen Grate Firebox Valve Access Panel Nailing Flange FP1644 1/2" Gas Supply GF598nvb GAS SUPPLY INSTALL12/4/97 Fig. 9 Exterior chase installation. 1/2" x 3/8" Shut-off Valve 3/8" Nipple 3/8" Union 3/8" Nipple FP598 Fig. 10 Typical gas supply installation. HV105Generic Gas Valve9/22/99 djtTPTHTHTP Remote Wall Switch NOTE: Use an approved outdoor switch. 1. Thread wire through the low voltage wire access hole located on either side of unit. Do not cut wire or insulation on metal edges. Ensure that wire is protected. Run the other end to a conveniently located wall receptacle box. 2. Attach wire to switch and install switch into receptacle box. Attach cover plate to switch. 3. Connect wiring to gas valve. Refer to Figure 11. CAUTION: Do not wire millivolt remote wall switch for gas appliance to a 120v power supply. For lighting instructions, refer to Page 12. Pilot Thermodisk Valve NOTE: If glass doors are installed, the unit must be operated with the doors fully open. (Fig. 12) If the doors are not fully open, the thermodisk will automatically turn the unit off. CAUTION: After the unit cools, the burner will automatically come on. On/Off Switch HV105 Fig. 11 Remote switch wiring. MD706-7Glass Door Position1/20/99OPEN MD706-7 Wrong Correct Fig. 12 Correct door position during operation. Operating Instructions Log Installation 1. Remove logs from the packaging. As with all plastic, these bags are not toys and should always be kept away from children and infants. 2. Place left rear log on rear log support. Ensure that log is firmly positioned and there is no side-to-side movement. (Figs. 13 & 14) 3. Carefully place Ember Log between grate and burner. (Figs. 13 & 14) 4. Place the front of right rear log on the burner and the back of the log on the rear log support. 5. Place the top logs onto the locator notches. Ensure the logs are secure. (Fig. 13 & 14) Right Cross Log LG317UVODSR36 logs11/24/03 djt Left Cross Log Right Rear Log Left Rear Log Ember Log LG317 Fig. 13 ODGR400 log placement. Left Cross Log First Firing Upon completing the gas line connection, a small amount of air will be trapped in the line. When first lighting the unit with pilot light, it will take a few minutes to purge the trapped air. Once purging is complete, the pilot and burner will light and operate as indicated in the instruction manual. Subsequent lightings of the appliance will not require purging. When lit for the first time, the appliance will emit a slight odor for an hour or two. This is due to paint and lubricants used in the manufacturing process. After each lighting, vapor may condense and fog the glass; this moisture disappears in a few minutes of...

Эта инструкция также подходит к моделям:
Прочие аксессуары для дома - ODGR400 (1.38 mb)
Прочие аксессуары для дома - ODGR400 (1.38 mb)
Прочие аксессуары для дома - ODGR500 (1.38 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории