Войти:
Оценок - 3, средний балл: 3.3 ( )

Инструкция по эксплуатации Aruba Spa, модель 2003 Escape

Производитель: Aruba Spa
Размер: 214.13 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Reinstall the O-ring and retighten the union. WARNING Only turn union one turn counter clockwise. 3) To fill your spa, place garden hose directly in the filter. The spa holds 360 gallons (1620 litres) of water. You will notice that there is an indented wave in the spa. This is the water line. It is important that you maintain your water at this level. INITIAL ST INITIAL STINITIAL STAR ARART TT-UP -UP-UP Before proceeding with the initial start-up, make sure you have completed the start-up preparations from the previous section. The following procedures must be done in the order they are listed. HAZARD This system should be set to maintain a water temperature NO GREATER THAN 40° CELSIUS (104° F). 1) Make sure all of the jets are in the full open position, (refer to Hydrotherapy Jets, page 13). 2) The Electronic Operating System spa control has automatic functions that operate upon start-up and normal operation to protect the system. Power up system and “Pur” will appear for 30 seconds while system is in purge mode then normal operation will resume. 3) With the breaker in the “On” position check to see if water is circulating. If not then you must prime the pump. To prime the pump turn union #1 slowly 1/2 to 1 turn to release air, being careful not to open too far. After you hear the water begin circulating, retighten the union. The pump must be primed every time the water is changed. Check to see if water is coming from all the jets. 4) At the end of the boot up, 30 seconds, the pump will be in high speed until the water temperature reaches 52°F. If your water temperature is below 39°F, at the time of fill, the topside control will toggle back and forth reading th2/39. The pack system is in lockout and the pump will run in high speed until the water temperature reaches 52°F. Once the water temperature has reached 52°F, the pump will then run in low speed. You can now set your water temperature to your desired level. Note: At the time of boot up, your spa will automatically go through its first filtration cycle for 2 hours. 5) Press the pump button on the control panel to test if the pump is changing from low to high-speed, (refer to Topside Control Component Identification, next page). You will be able to tell the difference between low and high-speed by the sound of the water moving through the spa’s plumbing system. Press the pump button again to return the pump to low speed. 6) Once the water has reached the set temperature add chem icals to adjust the water balance (see Chemical Maintenance, page 19). 7) The spa pack is thoroughly tested before shipping. The most common cause of immediate pack failure is dry firing (this occurs if the pump is running and the water is not circulating) and this type of failure is not covered by warranty. 8) If you experience any problems with the procedures above contact an Aruba customer service representative. 9) After your spa is operational you must install the Spa Cover latches. The locks will already be attached to the end of the straps. Position the tie strap so it is fully extended, without stretching. Locate the 2 holes on the locking mechanism, marking them with a pen. Remove the locking mechanism from the strap and fasten to the spa. HAZARD Never leave an uncovered spa unattended, and never leave a covered spa unlatched. SP SPSPA OPERA A OPERAA OPERATIONS GUIDE TIONS GUIDETIONS GUIDE T TTopside Contr opside Contropside Control Component Identification ol Component Identificationol Component Identification Heat HeatHeat s and Heat and Heatand Heat t buttons buttonsbuttonsThe spa’s thermostat is to provide you with optimum control of the spa water temperature. This temperature set point can be adjusted from 21° C (70° F) to 40° C (104 degrees F). Invert Button Invert ButtonInvert ButtonThis button will flip the LED readout 180°. Pump button Pump buttonPump button The control panel button designated “PUMP” activates the pump when pressed. The pump sequence is low speed, high speed, off. The pump, when the “PUMP” button is manually pressed, turns off after thirty minutes (a thirty-minute default). NOTE: You will not be able to turn off your pump if your spa is in a filter cycle, heating, or in freeze protection (less than 52°F). Light LightLight The control panel button designated “LIGHT” activates the spa light when pressed. The light turns off after two hour (a two-hour default). Filter Cycle Pr Filter Cycle PrFilter Cycle Programming ogrammingogramming Proper filtration is an important key to maintaining the clarity of your spa’s water. The filter system is designed for unsurpassed effectiveness at removing debris and suspensions from the water while the water is circulating. By pressing the Heat key and the Program key at the same time, you can adjust your filtration cycle from the factory setting of 2 hours every 12 hours, in 1-hour intervals. NOTE: If the water temperature does not drop the internal timer still operates the filter cycle to ensure proper filtra...

Эта инструкция также подходит к моделям:
Прочие аксессуары для дома - 2003 Breeze (214.13 kb)
Прочие аксессуары для дома - 2003 Serenade (214.13 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории