Войти:
Оценок - 4, средний балл: 4.5 ( )

Инструкция по эксплуатации Sundance Spas, модель Spas 880 Series

Производитель: Sundance Spas
Размер: 1.5 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Consider: . How should water spills be handled? . How many drains should be installed? . What is the best flooring to install near the spa? . If a leak occurs, can the floor handle the entire contents of the spa? . Will the furniture and walls around my spa withstand and resist water and moisture? . What provisions should I make for the ceiling and structures that may be below the spa. If the spa is being installed on a second story or higher, consult a structural engineer to discuss the best way to support the spa. Special attention is needed to plan for a spa installed on a balcony or roof. Most spa servicing is performed on the spa equipment that is located behind the panels of the spa. It is important to install the spa to allow easy access to the spa equipment. When the spa is in use, considerable amounts of moisture/water are present. Over time, this moisture may cause mold and mildew and damage to certain surfaces and/or surroundings. Proper ventilation should be discussed with an engineer who understands the necessity of venting moist and heated air that is associated with chemical emissions. Consult your local state or city building ordinances to ensure installation is in accordance with local codes. Any damage caused if you do not follow these guidelines voids the spa’s warranty. Planning to Move the Spa into your yard Planning to Move the Spa into your yard Check your spa’s dimensions Plan the delivery route Use a crane Check the width of gates, doors, and sidewalks to make sure your spa will pass through unobstructed. During delivery, the spa must remain on the delivery cart at all times. You may have to remove a gate or part of a fence to allow an unobstructed passageway to the installation location. After referring to Figure 2, plan your spa’s delivery route into your yard. Check off each item on the checklist below to verify your plans. . If the delivery route requires a 90° turn, check the measurements at the turn to ensure the spa will fit. . Are there protruding gas or water meters, or A/C units obstructing the delivery path to your yard? . Are there low roof eaves, overhanging branches, or rain gutters that could be an obstruction to overhead clearance? . Are there more than 6 consecutive stairs without a landing in your delivery route? If so, you must consult your Sundance dealer prior to delivery to make adequate preparations. The use of a crane for delivery and installation is sometimes necessary. It is used primarily to avoid damage to your spa, your property, or to delivery personnel. Your authorized Sundance dealer may be able to assist you with the arrangements. If your spa delivery requires the use of a crane, the cost of a crane is not included in standard delivery service. Continued on next page Planning to Move the Spa into your yard, Continued Planning to Move the Spa into your yard, Continued Check corner clearance. The spa can not bend. Be aware of other structures that might be in the way, such as dog houses, wood piles, etc. Check all gates and entries for width clearance. more than 6 in a row without a landing. Check protruding meters, fixtures, and rain gutters. Check the number of stairs, there should be no Check overhang clearances. Figure 2 Check for obstacles in the delivery route BEFORE receiving your new spa electrical Tasks Before Spa delivery electrical Tasks Before Spa delivery + Before the installation of your spa begins, check with the local building department to ensure this installation conforms to local building codes. important When installed in the United States, the electrical wiring of this spa must meet the requirements of the National Electric Code (NEC) and any applicable state or local codes. The electrical circuit must be installed by an electrical contractor AND approved by a local building/electrical inspector. Never use an extension cord of any kind. Using an extension cord can damage the spa equipment and void your warranty. The Sundance Denali, Dover, and Tacoma North American models include a 10 foot GFCI cord for plug-in 120V operation. Connect this cord directly to a dedicated/grounded wall outlet. When a power cord over 10 ft. is required, the spas must be hard wired in accordance with state and local codes. Before the scheduled arrival of your spa, it is necessary to set up the electrical components. Use the checklist below to prepare for the spa’s installation. r Prepare the electrical connection for your spa based on one of the configurations listed below. If necessary, refer to the Power Configuration tables for additional information by model. if installing a spa that is … Then it must be … 240V (North America) Hard wired to the power supply. 120V (USA only) Plugged into a dedicated grounded outlet using the GFCI cord supplied with the spa. 120V (Canada) Hard wired to the power supply per CSA standards. Continued on next page electrical Tasks Before Spa delivery, Continued electrical Tasks Before Spa delivery, Continued • connections ...

Эта инструкция также подходит к моделям:
Прочие аксессуары для дома - Spas 780 Series (1.5 mb)
Прочие аксессуары для дома - Spas 680 Series (1.5 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории