|
Фрагмент инструкции
NOTE: There are five sealing washers (21). One is for use in the hexagon nut of the S.S. flexible hose, another is used for the hand shower. The remaining three sealing washers are spare parts to be stored for later use. NOTE: Flush the water lines supply lines to eliminate any construction debris prior to connecting water lines. Ensure there is no particle contamination on the threaded ends of the water supply pipe. Debris and particles in the water supply will reduce shower performance. Figure 4 1 4 11 3 1 21 Parts List The parts list table common to all Ristorre shower towers is located on Page 9. Please refer to this table for component identification of parts list in all Ristorre shower towers. Figure 5 26 Mirror Installation 27 14 25 23 24 Figure 6 21 5 22 16 22 2. Connect 1/2" hoses from the front plate (1) marked in red and blue to the hot and cold water supply’s, respectively, as shown in Figure 7. NOTE: Do not bend or kink the hoses when installing. Tighten fittings with a wrench and test for leaks. 3. Align the three mounting holes of the back housing (5) and front plate (1) with the three mounting rods (7) on wall. Fasten the front plate to the fixing rods and attach with the washers (9) and cap screws (10) provided. NOTE: Figure 8 shows the hot and cold supply locations. BLUE HOSERED HOSEHOT WATER SUPPLYCOLD WATER SUPPLY Figure 7 RED AND BLUE WATER SUPPLY LINES (1/2" NPT Thread) 7 5 5 10 7 9 9 10 7 Onda Ovale Metallo Figure 8 Place supply lines within hatched region Place supply lines within hatched region Place supply lines within hatched region 6.25" 2.00" 2.00" 6.25" 6.25" 3.50" 11.00" 18.50" 4. Using the dimensions indicated in Figure 9, drill two holes 1/4” diameter by 1-3/8” deep into the wall on the right hand side of the shower tower. Insert the plastic anchors (18) into each of the holes, and mount the bracket (17) onto the wall using the M3.5x25mm Screws (19). 5. Confirm the sealing washer (21) is inside the end of the S.S. flexible hose (16). Attach the hand shower (15) onto the hose by hand and place the hand shower into the bracket as shown in Figure 10. 6. After finishing the installation, the shower tower is ready for use. 7. There is an optional tube-shaped temperature check spout (13) as an alternative to the pre-installed square- shaped temperature check spout (12). To exchange these two components, use a hand wrench (not supplied) to remove the supply hose connecting nut attached to the square-shaped temperature check spout. Remove the mounting nut of the spout to release it. After that, install the tube-shaped temperature check spout into the mounting hole and tighten it, and mount it with the supplying hose, see Figure 11. NOTE: To avoid scratching the front surface, do not turn square spout. Hold and remove washer rather than remove the square spout. 2" (23mm) 9-7/8" (250mm) 63" (1600mm) TOFLOOR2HOLES1/4"DIA.(6,4mm)x1-3/8"(35mm) DEEP2HOLES1/4"DIA.(6,4mm)x1-3/8"(35mm) DEEP191618 Figure 9 17 19 18 152116 Figure 11 12 12 Figure 10 13 1. CONTROL VALVE. The Control Valve consists of three parts, the diverter (20a), flow control (20b), and thermo-static control (20c). a. Diverter The Diverter (20a) works as a function selection. Four icons on the diverter indicate the function selected. The four icons represent the following four functions: Hand shower spray , Body jets , Wall mount spray , and Bath spout . b. Flow Control The Flow Control (4b) is located in the center of the Control Valve and is used to control the water flow volume. Increase the water flow by turning the handle to the left and decrease by turning to the right. c. Thermo-Static Control The thermo-Static Control (20c) is used for setting the water temperature. There are the “H” and “C” letters, and red and blue colors representing Hot and Cold, respectively. Users can adjust the water temperature as they want by turning the control handle. CAUTION: The “38° C” (100° F) mark on the control represents the safety temperature level. If a higher water temperature is needed, turn the handle left while pressing the red button. CAUTION: Remember to return the handle to the “38°C” after use at the higher water temperature. 2. BRACKET. Use the wall mounted bracket (16) to hold the hand shower (15) on wall. Select "??" on the Diverter to activate the hand shower. Troubleshooting 1. If the water flow rate is reduced or if there is no water flow while using a specific function, dismount the shower tower and verify the main water supply hoses (blue and red supply lines) or tubing are not bent or kinked. 2. During operation, if only cold or hot water is supplied but no combination, please check to see if the thermo-static control (20c) is set at the middle level. Also check for bending or kinking in the main cold or hot water supply lines. Cleaning Do not use sand paper, thinner or other corrosive cleaner. Normal non-abrasive household cleaners can be used. Rinse with water. OPERATION 20a 38 20b 20c Proper installation of the ...
Эта инструкция также подходит к моделям:Прочие аксессуары для дома - Ristorre Metallo EC33000 (7.85 mb)
Прочие аксессуары для дома - Ristorre Ovale EC31000 (7.85 mb)