The last measured temperature is constantly displayed on the LCD. Note that the last measured spa temperature displayed is current only when the pump has been running for at least 2 minutes. Press the “Warm” or “Cool” button to display and adjust the set temperature. After three seconds, the LCD will automatically display the last measured spa temperature. Jets Touch the “Jets” button once to activate the low speed of the pump and again for the high speed. Press the “Jets” button again to turn off pump 1. If left running, the pump’s low speed will automatically turn off after 4 hours, and the pump’s high speed will automatically turn off after 15 minutes. The pump’s low speed runs when the spa is heating, when a filter cycle is activated, or when a freezing condition is detected. When the low speed turns on automatically, it cannot be deactivated from the panel; however, the high speed may be started. Note: The pump can also be activated by an optional auxiliary control button. Light Press the “Light” button to turn the spa light on and off. If left on, the light automatically turns off after 4 hours. If a fiber optic light is installed, press the “Light” button once to start the light and wheel, press it again to stop the wheel, and then again to turn the light off. Blower This button turns the blower on and off. The blower automatically turns off after 15 minutes. Mode This button is used to switch between Standard, Economy, and Sleep Modes. (over) 2000LE M-7 Control Reference Card Non-Circ Operation Initial Start-up When your spa is first activated, it will go into Priming mode, indicated by “ .”Please see the M-7 Installation Instruction Manual for complete instructions on Power-up and Pump Priming. The Priming mode will last for less than 5 minutes and then the spa will begin normal operation in Standard Mode. Standard Mode is programmed to maintain the desired temperature. Note that the last measured spa temperature displayed is current only when the pump has been running for at least 2 minutes. “ ” will be displayed momentarily when you switch into Standard Mode. Economy Mode heats the spa to the set temperature only during filter cycles. “ ” will display solid when temperature is not current, and will alternate with temperature when temperature is current. Sleep Mode heats the spa to within 20°F of the set temperature only during filter cycles. “ ” will display solid when temperature is not current, and will alternate with temperature when temperature is current. Preset Filter Cycles The first filter cycle begins 6 minutes after the spa is energized. The second filter cycle begins 12 hours later. Filter duration is programmable for 2, 4, 6, 8 hours or for continuous filtration (indicated by “FILC”). The default filter time is 2 hours. To program, press “Warm” or “Cool,” then “Jets.” Press “Warm” or “Cool” to adjust. Press “Jets” to exit programming. The blower purges for 30 seconds at the beginning of each filter cycle. The low speed of the pump runs during filtration and the ozone sterilizer (if installed) will be enabled. Freeze Protection If the temperature sensors detect a drop to approximately 44°F/6.7°C within the heater, then the pump and the blower will automatically activate to provide freeze protection. The equipment stays on until 4 minutes after the sensors detect that the spa temperature has risen to approximately 45°F/7.2°C or higher. In colder climates, an optional additional freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard sensors. Aux freeze sensor protection acts similarly except with the temperature thresholds determined by the switch and without a 4-minute delay in turnoff. See your dealer for details. Spa is shut down. The sensor that is plugged into the Sensor “B” jack is not working. Sensors are out of balance. If alternating with temperature, it may just be a temporary condition. If flashing by itself, spa is shut down. A substantial difference in temperature has been detected between temperature sensors. This could indicate a flow problem. Persistent low flow problems. (Displays on the fifth occurrence of the “HFL” message within 24 hours.) Heater is shut down, but other spa functions continue to run normally. Inadequate water detected in heater. Inadequate water detected in heater. (Displays on third occurrence of “dr” message.) Spa is shut down. and disappear when the heater cools.) If the problem persists, contact your dealer or service organization. (May appear temporarily in an overheat situation and disappear when the heater cools.) If the problem persists, contact your dealer or service organization. Check water level in spa. Refill if necessary. If the water level is okay, make sure the pumps have been primed. If problem persists, contact your dealer or service organization. Follow action required for “HFL” message. Turn spa off then back on again to restore heating capability. Check water level in spa. Refill if ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории