Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации Napoleon Fireplaces, модель GI3016-P

Производитель: Napoleon Fireplaces
Размер: 345.01 kb
Название файла: d759df01-9244-4fc2-9926-f1a2148b8117.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Take the time to FLAME IMPINGEMENT AND CARBONING. carefully position the charcoal embers for a maximum glowing effect. FIGURE 10 1. Place the front log onto the main burner, pushing it as close as possible to the burner ports without blocking/covering them. The left and right spacing between the log ends and the burner ports should be equal. 2. Place the back log onto the log support brackets located on the rear wall of the combustion chamber. The notch situated at the lower left of the back log should be centred evenly above the pilot assembly. 3. While supporting the back log, to prevent it from falling forward, set the three smaller logs into the pockets and grooves of the front and back logs, respectively. Log colours may vary. During the initial use of the fireplace, the colours will become more uniform as colour pigments burn in during the heat activated curing process. CHARCOAL EMBERS Randomly place the embers along the front burner ports. Keep ember dust away from burner ports to avoid plugging them. Fine dust found in bottom of bag not to be used. PHAZERTM logs and charcoal embers glow when exposed to direct flame. Use only certified PHAZERTM logs and charcoal embers available from your Napoleon dealer. FIGURE 11 W415-0171 / D / 01.06.04 FLUSH GLASS FRONT KIT, GI-FF FLUSH LOUVRE KIT, GI-1L FLUSH GLASS FRONT KIT, GI-FF FLUSH LOUVRE KIT, GI-1L Attach the lower glass bracket. Seat the glass inside the bracket and using two screws attach the upper glass bracket, as shown. FIGURE 12a FLASHING SURROUND KITS, GI-900 / GI-909 Assemble the flashing and mount to the inside of the outer shell using 4 securing screws (supplied with the louvre kit). LOWER GLASS BRACKET LOGO13/8" SECURING SCREW LOCATIONS LOGO PLACEMENT FIGURE 12b FIGURE 13 11/8" Remove the backing of the logo supplied and place on the glass viewing area, as indicated. FIGURE 14 SIDE VIEWUPPER LOUVRE LOUVRE CLIP UPPER LOUVRES Insert the back edge of the upper louvre into the upper louvre clips. LOWER LOUVRES Secure the lower louvre assembly to the insert, using the 4 screws supplied. W415-0171 / D / 01.06.04 BAY GLASS FRONT, GI-BF BAY GLASS FRONT, GI-BF FIGURE 17 FIGURE 18 ORNAMENTAL FLUSH INSETS, GI-OI Assemble the flashing and mount to the inside of the outer shell using 4 securing screws and spacers (supplied) as shown. Hook the ornamental inlays over the spacers. FIGURES 15 LOWER UPPER With the bay chassis on a flat surface, insert the front glass (bottom first) and centred to the mitred edges of the chassis. Fit the bevelled edge of the each side glass piece tightly to either edge of the front glass. Secure the glass by bend- RETAINER TAB ing up the retainer tabs at the top and bottom. Spread and insert the spring clips between the side glass and the chassis (2 per side). Place the front brick panel pieces into place at the bottom. SPRING CLIP FIGURES 16 Secure the bay to the insert front at the top and bottom outside corners using 4 screws. BAY LOUVRES, GIB-L Note: Black louvre assembly, if supplied, must be installed as uppers, due to the high fireplace temperature. ORNAMENTAL BAY INSETS, GI-OI FIGURE 19 FIGURE 20 MAGNET MAGNET W415-0171 / D / 01.06.04 Both these options may be attached to the insert front using 4 magnets, positioned as shown: NOTE:The ornamental bay inlays can be adjusted to align with the bay door assembly. 10 W415-0171 / D / 01.06.04 If your masonry fireplace is equipped with a fresh air inlet in the floor of the firebrick chamber, the insert is able to take outside air directly into the unit through an opening in its base thereby eliminating the need to use preheated room air for combustion. The flow of air may be adjusted through the use of a damper located below the louvre access door. The damper should be kept closed (pushed all the way in) when the unit is not in operation or if no outside air is available. The damper is fully open when pulled forward (one inch from the closed position). FIGURE 22 Never obstruct the flow of combustion or ventilation air. When lit for the first time, the stove will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to sufficiently ventilate the room. After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to sufficiently ventilate the room. Call a qualified service technician. Force or attempted repair may result in a fire or explosion. D Do not use this insert if any part has been under water. Immediately call a qualified service technician to inspect the unit and replace any part of the control system and any gas control touched by water. A This stove has a pilot which must be lit by hand while following these instructions...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории