Войти:
Оценок - 2, средний балл: 5 ( )

Инструкция по эксплуатации Weslo, модель Daybreak 515 WLHS42081

Производитель: Weslo
Размер: 2.58 mb
Название файла: 299d4edf-5009-4c7f-8ca8-7930bbfe4abe.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Two more jets are located on each of the bench seats, and they focus the water massage on your lower or middle back. The spa also features an ozone jet (C) which is part of the built-in ozone generator system. Ozone helps sanitize your spa with minimal chemical treatment. The suction vents (D) located near the floor of the spa brings the water into the pump in order to operate the system. The suction covers should always be in place over the suction vents. Never operate the spa without the suction covers in place. The filter (E) can be removed for replacement and cleaning (see CHECKING AND CLEANING THE FILTER on page 18). The temperature probe (F) reads the current water temperature which is displayed on the console. The DAYBREAK 515 also has a light (G) for your safety and convenience during evening use. Use of the Console (H) and the Diverter (I) is explained on pages 12 and 13 of this manual. The DAYBREAK 515 offers automatic freeze protection. If the water temperature falls below 40.F, the pump will begin circulating and heating the water to prevent the water from freezing. 11 CONSOLE DIAGRAM USING THE CONSOLE Refer to the console diagram above. The function of each console control is explained below: Temperature Display: During normal use this display shows the actual water temperature. When the Set Temp indicator is lit, the display shows the set temperature. Light: This button turns the light on and off. When the light is on, the indicator above the light button will be lit. The light will automatically turn off after two hours. Pump: This button turns the pump on and off. When the pump is running, the LED indicator above the button will light. To turn the pump on high, press the button once. The thera-jets will operate at full speed. To turn the pump on low, press the control twice. The thera-jets will operate at low speed. After you press the button a third time, the thera-jets will shut off, unless it is time for the heat or filter cycles. If you turn the pump off and it continues to operate, check if the Heat On or Filter On indicators are lit to see if either cycle is running. Set Temp: This indicator will light when the temperature is adjusted by using the up and down buttons. To adjust the temperature, press either the up or down buttons to select a new temperature. The thermostat can be set to heat the water from 41.F to 104.F. While you are setting the temperature, the temperature display will show the new temperature. The new temperature will remain in the display for five seconds after you release the buttons. Then the Set Temp light will turn off and the display will return to the actual water temperature. The water heats at 1.0 to 2.0.F per hour with the cover on. Heat On: This LED indicator is lit when the spa is running the heating cycle. Filter On: This LED indicator is lit when the spa is running the filter cycle. Note: To keep the heat and filter cycles from running, shut off the circuit breaker or GFCI. Air Control: Determines the amount of air that is in the spa jet system during operation. If the control is turned to the left, the amount of air flowing through the jets will increase. If the control is turned to the right, the amount will decrease. Error Messages: When certain problems occur, the Temperature Display will show an error code. The error codes are explained below: HL High temperature protection mode. If the water temperature rises above 115.F, the heater will shut off. If the temperature rises above 122.F, the high temperature circuit will shut off the entire system. In either case, once the water has cooled to normal, you can press any button to reset the system. FrE Freeze protection mode. If the water temperature falls below 40.F, the pump will begin cycling the water through the heater to raise the temperature. This cycle will run for one minute and may be repeated as needed. FLC Flow related problems. You will need to call our customer service department. FLO Flow related problems. You will need to call our customer service department. PrH High temperature probe problem. You will need to call our customer service department. Prr Temperature probe problem. You will need to call our customer service department. 12 USING THE DIVERTER The Diverter is located on the other side of the spa from the console. The Diverter controls the flow and intensity of the water through the hydrotherapy jets. Diverter Left Diverter Right Diverter Middle Refer to the drawing above. When the diverter is turned to the left, the pump will provide intense hydrotherapy through the eight jets shown above the dotted line. When the diverter is turned to the right, the pump will provide intense hydrotherapy through the seven jets shown below the dotted line. When the diverter is set in the middle, the pump will provide equal water pressure through all fifteen hydrotherapy jets. ADJUSTING THE FILTER CYCLE The spa filter cycle runs automatically to clean the water in the spa. However, the number ...

Эта инструкция также подходит к моделям:
Прочие аксессуары для дома - Daybreak 515 WLHS42081 (2.58 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории