Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Vermont Casting, модель 36CDVRRN

Производитель: Vermont Casting
Размер: 3.76 mb
Название файла: 3e247606-a679-4898-9f51-c768592d4c41.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• Do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas suppliers instructions. • If you cannot contact your gas supplier call the Fire Department C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand do not try to repair it, call a qualified service technician. Force or attempting repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and replace any part of the control system and any gas control that has been under water. Lighting Instructions 1. STOP! Read the safety information above before continuing. 2. Turn off all electrical power to the appliance. 3. This appliance is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand. 4. Access the gas control by lowering the lower access door (louvre assembly). 5. Turn the remote switch, if used, OFF. Turn the wireless remote, if used, OFF. 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas STOP. Follow instructions B in the safety warnings above. If you do not smell gas go onto the next step. 7. Close the access door. 8. Turn ON all electrical power to the appliance. 9. Turn remote switch or wireless remote to “ON”. 10. If the appliance will not operate, follow the instructions TURNING OFF THE GAS TO THE APPLIANCE and call your service technician or gas supplier. HI LO Turning Off the Gas to the Appliance 1. Turn the remote switch to the “OFF” position. 2. Turn OFF all electrical power to the fireplace if service is required. 3 Open the lower access panel. 4. Turn the shut-off valve on the flexible gas line to the “OFF” position. FP297AValve in the on position 1/2” Gas Supply 1/2” NPT x 1/2” Flare Shut-Off Valve 3/8” Flex Line (From Valve) 20010175 31 CDV Series Direct Vent Gas Fireplace Troubleshooting the Gas Control System SIT NOVA 820 MILLIVOLT VALVE NOTE: Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or misaligned electrode at pilot. Using a match, light pilot. If pilot lights, turn off pilot and push the red button again. If pilot will not light - check gap at electrode and pilot-should be 1/8” to have a strong spark. B. Defective ignitor (Push Button) Push Piezo Ignitor Button. Check for spark at electrode and pilot. If no spark to pilot, and elec trode wire is properly connected, replace ignitor. 2. Pilot will not stay lit after carefully following lighting instructions. A. Defective pilot generator (thermocouple), remote wall switch. Check pilot flame. Must impinge on thermo couple/thermopile. Note: this pilot burner assem bly utilizes both-a thermocouple and a thermopile. The thermocouple operates the main valve operation (On and Off). Clean and or adjust pilot for maximum flame impingement on thermopile and thermocouple. B. Defective automatic valve Turn valve knob to “Pilot”. Maintain flow to pilot; milivolt meter should read greater than 10 mV. If the reading is okay and the pilot does not stay on, replace the gas valve. Note: An interrupter block (not supplied) must be used to conduct this test. 3. Pilot burning, no gas to main burner A. Wall switch or wires defective Check wall switch and wires for proper connec tions. Jumper wire accross terminals at wall switch, if burner comes on, replace defective wall switch. If okay, jumper wires across wall switch wires at valve, if burner comes on, wires are faulty or connections are bad. B. Thermopile may not be generating sufficient millivoltage. 1. Be sure wire connections from thermopile at gas valve terminals are tight and thermopile is fully inserted into pilot bracket. 2. One of the wall switch wires may be grounded. Remove wall switch wires from valve terminals if pilot now stays lit, trace wall switch wiring for ground. May be grounded to fireplace or gas supply. 3. Check thermopile with millivolt meter. Take reading at thermopile terminals of gas valve. Should read 250-300 millivolts (minimum 150) while holding valve knob depressed in pilot position and wall switch “Off”. Replace faulty thermopile if reading is below specified minimum. C. Plugged burner orifice. Check burner orifices for debris and remove. D. Defective automatic valve operator. Turn valve knob to “On”, place wall switch to “On” millivolt meter should read greater than 100 mV. If the reading is okay and the burner does not come on, replace the gas valve. 4. Frequent pilot outage problem. A. Pilot flame may be too low or blowing (high) causing the pilot safety to drop out. Clean and/or adjust pilot flame for maximum flame impingement on thermopile and th...

Эта инструкция также подходит к моделям:
Прочие аксессуары для дома - 36CDVTRN (3.76 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории