The system has detected a problem. Contact your local Authorized Dimension One Spas Dealer, or authorized service center. Using the Programmable Digital Controller To initiate the programming sequence at any time, push and hold the PROGRAM pad for 3 seconds. If, within 10 seconds, you do not proceed with the hot tub programming, the hot tub will automatically exit the programming sequence and revert to the pre-set factory default settings. To exit the programming sequence at any time, do not press any pad for 10 seconds. Any programming changes made up to that point will be saved. Filter Cycle Start Time To adjust the filter cycle start time, push the UP or DOWN pads and LIGHT pad as done in the Clock Set programming mode to choose a time. Once the desired time is displayed, push the PROGRAM pad to accept the selection and move into the Filter Cycle Duration programming mode. You will be prompted later to set the filter cycle duration and the number of filter cycles. Be sure to keep this in mind when programming your filter cycle start time. During the filter cycle, JET 1 will activate at high speed the first 5 minutes and the remainder of the filter cycle time at low speed. Filter Cycle Duration To adjust the filter cycle duration, push the UP or DOWN pads to cycle through the choices of 60, 90, 120, 150 or 180 minutes (the default is 60). Once the desired time is displayed, push the PROGRAM pad to accept the selection and move into the Number of Filter Cycles programming mode. Long and/or numerous filter cycles could cause overheating of the hot tub - especially in hot climates. Number of Filter Cycles To adjust the number of filter cycles per day, push the UP or DOWN pads to cycle through the number of filter cycles - 1, 2, 3 or 4 (the default is 2). Once the desired number of cycles is displayed, push the PROGRAM pad to accept the selection and move into the Temperature Unit Selection programming mode. Temperature Unit Selection To select temperature units push the UP or DOWN pads to toggle between ° F (degrees Fahrenheit) or ° C (degrees Celsius). Once the desired temperature unit is selected push the PROGRAM pad to exit the programming mode. Initial Startup 1. Locate the Top Side Control. Directly below this control is the equipment compartment. 2. Use screwdriver to remove the spa panel screws. The number of screws to be removed will depend on the make and model of spa. On initial start-up, you can confirm that the heater is on by looking to see that the HEAT Indicator Iight located above the Digital Display on the control panel is illuminated. Once you have verified that the heater is functioning, you can reinstall the equipment door. 11. After completing the above steps, it is necessary to ensure proper water chemistry. See the Water Chemistry section in this manual for the easy steps to maintaining clean and safe water. The schedule shown may require more frequent adjustment depending on the bather load. 12. Place the thermal cover on the spa to conserve energy and to keep it ready for use. Care for Your Hot Tub Risk of Accidental Drowning. Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot use this system unless they are supervised at all times. Draining Your Hot Tub All Dimension One hot tubs are gravity drained. Do not drain water onto your lawn or plants unless all of the bromine or chlorine has dissipated from the hot tub water. The sanitizer in your hot tub water will dissipate quickly by leaving the hot tub cover off and exposing the water to direct sunlight. Drain and replace your hot tub water every six months. For heavy hot tub use, you may wish to change the water more frequently. Filter Cleaning Always turn off the power to the hot tub before cleaning the filter elements. Your hot tub is equipped with one or two top access filter cartridges. We recommend that you clean the filters every month as preventative maintenance. To clean the filter cartridge, remove the access lid covering the filter area. Lift the center float of the skimmer assembly until it is fully extended. Hold the centerpiece of the assembly and turn it counter clockwise until the flats of the basket are aligned with the securing tabs. Then pull the basket assembly straight up to remove. Next, remove the E-Z Lock Filter cartridge by twisting the cartridge 1/4 turn counterclockwise to its stop. (Be careful not to overturn the filter) Then lift the filter out of its canister. Clean the cartridge with a high-pressure garden hose. Every other cleaning, soak the cartridge in a filter cleaning solution, rinse it thoroughly, and reinstall. Replace the skimmer basket assembly and the access lid or cover. After cleaning, run the pump for a few minutes at high speed, then return to the heating mode. Light Bulb Replacement All systems are equipped with a 12 volt light using a GE912 bulb. To change the bulb: 1. Turn the power off and drain the system below t...
Эта инструкция также подходит к моделям:Прочие аксессуары для дома - @home Dream HP (4.33 mb)