|
Фрагмент инструкции
6 How to maintain your shower …………… 10 Guarantee …………… 12 How to use your shower 1. Ensure the electricity and water are turned on to the unit 2. Function of controls : - KNOB “A” – Power selector. (On/off 600 only) KNOB “B” – Adjusts the flow / temperature of the water BUTTON “C”– Starts and ‘Shuts down’ the shower and cools the water automatically for (620 only) the next shower. 3. Turning the unit on Model 600 – Rotate knob “A” clockwise a . turn (one click) this will select full power, the normal setting, further turns change the power setting (see above). Model 620 – Press button “C”. (Rotating knob “A” selects the power level, full power being the normal setting - see above). 4. You will now need to adjust the temperature of the water. Rotate knob “B”. If the temperature is too low rotate knob “B” anti clockwise and allow 20 seconds for the temperature to settle. Repeat this procedure until the temperature is to your liking. 5. If the temperature is too high then turn knob “B” clockwise allowing 20 seconds between adjustments. The final adjustment can be anywhere on the scale. See diagram 2 for relationship of flow to temperature. 6. Clockwise makes the temperature cooler, anti-clockwise makes the temperature warmer. 7. Once a temperature setting to your liking has been achieved knob “B” will rarely need adjusting, e.g. Adjust for variations of incoming mains water temperature between summer and winter. 8. The options of Medium or Low, reduces the power used giving a cooler shower or the option of reduced flow. These options are mainly for summer usage and knob “B” will have to be re-adjusted. The cold option (620 only) supplies water with no heat. 9. When you have finished showering. Model 600 -Rotate knob “A” to the 12 o’clock position ( ). The electricity is switched off and the water will cease to flow immediately. Model 620 - Press button “C”. The electricity to the elements is then switched off, water will continue to flow for approximately 5 seconds before switching off. This reduces the temperature of the water in the unit. Switch the electricity off at the ceiling switch or local isolator. 10.Your shower is designed to stabilise temperature changes caused by water pressure fluctuations. These can result from toilets being flushed or taps being turned on or off. When this happens your showering temperature will be held within a controlled band, provided that the minimum pressure required by the shower is maintained. 11.Your shower requires a minimum operating pressure of 100 kPa (1.0 bar, 14.5 p.s.i.). At pressures above 100 kPa (1.0 bar, 14.5 p.s.i.) it will minimise temperature fluctuations detailed in note 9. If the water pressure falls below 100 kPa (1.0 bar, 14.5 p.s.i.), it is likely that the pressure switch will turn off the power to the heating elements, resulting in a cold shower. 12.During normal operation if the shower senses an overheated water temperature then the thermal cutout will switch off the heating elements. Water will continue to flow and as the water temperature falls the heating elements will be turned back on. If the unit continues to do this then increase the flow rate by turning knob “B” clockwise and check that the handset does not require de-scaling. If it still continues, then rotate knob “A” to the MEDIUM power setting, six o’clock position (Knob B will need adjusting). 13.Note that knob “B” IS NOT A TAP and does not turn the water off. WARNING! DO NOT SWITCH THE SHOWER ON IF YOU SUSPECT IT OF BEING FROZEN. WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT. Redring After Sales Service We offer a technical advisory service on the telephone to contractors and other customers with problems in the field. RING 0870 9000 430 Spare parts can be supplied against any debit or credit cards. RING 0870 0102 829 Remember to quote the exact type of shower, as written on the front of the shower and on this leaflet. It may also be of use to have a note of the catalogue number and serial number as stated on the underside of the shower How your shower works Your shower is designed for convenience, economy and safety of use 1. Water is heated instantaneously as it flows over the heating elements in the copper heating tube. 2. The required water temperature is achieved by adjusting the rate of water flow. Diagram 2 shows the principle involved in relating temperature rise to flow rate. The higher the water flow the lower the temperature rise, and vice versa. The temperature of the water supplied from the mains can vary considerably throughout the year from 5 to 20°C. This means that in Winter, the flow rate will be less than in the Summer to achieve the same outlet temperature. In summer the ‘MED (medium)’ or ‘LOW’ power setting may give adequate hot water. a switch, which works on water pressure. 3. The water is turned on and off by the solenoid valve built into the shower. This is switched on by rotating Knob “A” (pressing button “C” - model 620 only) 4. The flow of water is automatically...
Эта инструкция также подходит к моделям:Прочие аксессуары для дома - 620 (2.16 mb)