Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации ProForm, модель PFSB43140

Производитель: ProForm
Размер: 640.66 kb
Название файла: f9cbbfdd-2008-4ec4-ab7a-15923d3de586.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


This will help protect the cover from sun damage. CHECKING AND CLEANING THE FILTER The filter should be checked periodically for build-up of dirt and oil. If the filter needs to be cleaned, follow the steps below: 1. Turn off the power. 2. Lift the filter cover. 3. Lift the the filter out of the filter housing. 4. Check the filter for dirt and debris. If the filter needs to be cleaned, rinse the filter with a hose. If the filter is still dirty, soak it in cleaning solution from a pool and spa supply store. 5. Inspect the filter for damage. Replace the filter if it is damaged. 6. Insert the cleaned or new filter into the fil- Filter Housing Filter Basket Filter Cover ter housing. 7. Reattach the filter cover. 16 WATER CHEMISTRY Maintaining the pH level of the water is very important to the operation of the spa. To maintain the proper pH level and to sanitize the spa, you can purchase a chemical starter kit from your local pool and spa supply store. CAUTION: The chemicals used to maintain the pH balance of the water and to sanitize the water can be dangerous. Always follow these basic guidelines when handling the chemicals: 1. Always read and follow the directions on the label, unless directed otherwise. 2. Never mix different chemicals. 3. Do not exceed the recommended amounts of chemicals—follow the directions on the label. 4. Keep all chemicals out of the reach of children and pets. 5. Keep all containers closed tightly when not in use. 6. Never add water to the chemicals—always add the chemicals to the water as directed. 7. Always store chemicals in a cool, dry place. MAINTAINING THE PROPER PH BALANCE The pH factor is a measure of the relative acidity or alkalinity in the water, and is measured on a scale of 1 to 14. Pure water has a value of 7, which is neutral. Any value above 7 is alkaline, and any value below 7 is acidic. You should maintain a slightly alkaline pH level, between 7.2 and 7.8, in the hydrotherapy spa. Severe problems can occur when the pH balance is not maintained within this range. If the pH level exceeds 7.8, dissolved minerals can build up and clog the plumbing in the spa jet unit. If the pH level falls below 7.2, the acid level in the water will begin to corrode the metal parts in the spa jet unit. Also, the sanitation agents in the water will not be effective if the pH level is not properly maintained. Damage caused by improper pH levels is not covered under the warranty. To maintain the proper pH level, test the pH of the water regularly. To test the water, purchase a pH test kit at a pool and spa supply store. The pH reading should be between 7.2 and 7.8. If the level is too low, add a pH increaser (usually soda ash). If the level is too high, add a pH reducer (usually sodium bisulfate). Test the water again after five minutes. See the instructions with your pH test kit for additional information about testing and adjusting the pH. SANITIZING THE HYDROTHERAPY SPA The most common sanitizing agent is a solid bromine concentrate. The amount required varies according to several factors, such as user load, temperature, and water conditions. Proper water maintenance is a complex process. Contact your local pool and spa supplier for information concerning which chemicals you should use in your area to sanitize the spa. CHANGING THE FILTER CYCLE The spa will filter the water every 12 hours. The duration of the cycle can be adjusted to last for 2, 4, 6, or 8 hours or to run indefinitely. Press the temperature up or temperature down button on the console. When the display begins to flash, press pump button 1. The display will read “F2.” To change the time, press the temperature up button until the desired time is reached. Press pump button 2 to confirm the selection. Pump 2 purges for five minutes and the blower purges for 30 seconds at the beginning of each filter cycle. Pump 1 will run on low during filtration and the ozone generator will be enabled. As spa usage increases, the duration of the filter cycle may need to be increased. 17 ATTACHING AND REMOVING THE ACCESS PANELS Shut off the power to the spa, at the circuit breaker or GFCI. To remove the indicated Access Panels (25), remove the eight #10 x 2” Machine Screws (39) that secure the Access Panels to the spa. Carefully remove the Access Panels and set them aside. 25 25 39 To replace the Access Panels (25), hold the Access Panels in place and secure them with the eight #10 x 2” Machine Screws (39). Be careful not to overtighten the Machine Screws. DRAINING THE HYDROTHERAPY SPA The hydrotherapy spa should be drained at least four times per year and refilled with clean water. You may need to drain the spa more often, depending on the user load. This must be done because after repeated chemical treatment the water becomes chemically saturated. Once this happens, additional chemical treatment of the water is no longer effective. The spa should also be drained if you will not be using it for long periods of time. The spa must always be ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории