|
Фрагмент инструкции
Thank You for purchasing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life. This manual contains the information needed to properly install this appliance, and to use, care for and maintain or repair the appliance in a manner which will ensure its optimum performance. WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 3 INSTALLATION INSTRUCTIONS 5 AGENCY APPROVAL INFORMATION 5 OPERATION 6 USERS GUIDE 7 CLEANING INSTRUCTIONS 8 SERVICING INSTRUCTIONS Operational Adjustments 9 Electrical 10 Plumbing 12 De-liming Heater Tank 14 Diagnostics & Troubleshooting 15 EXPLODED VIEW & PARTS LIST Airpot Brewer Models 16 Thermal Brewer Models 18 WIRING DIAGRAMS Airpot/Thermal Brewer Models 20 Export 240V thermal/airpot brewer 21 MODEL CONFIGURATION HEIGHT WIDTH OVER ALL DEPTH 2280/2286EX Thermal Brewer 27p (699 mm) 9b(231 mm) 22 D” (575 mm) 2282/2288EX Airpot Brewer 23p (599 mm) 9b(231 mm) 22 D” (575 mm) MODEL WATTS VOLTS HZ. CIRCUIT REQ. WIRE 2286EX 2288EX 3200 240 50/60 HARD WIRED TO BREAKER 2 + GND. SPECIFICATIONS 1 TABLE OF CONTENTS ELECTRICAL SPECIFICATIONS* MODEL WATTS VOLTS Hz CIRCUIT REQUIRED WIRE 2280 1800 120 50/60 15 AMP (NEMA 5-15R) 2 + ground 2282 1800 120 50/60 15 AMP (NEMA 5-15R) 2 + ground Canada 1500 watts DIMENSIONS* * for complete information regarding specifications and dimensions, please consult the GLD (General Layout Data) for the appliance ( p/n 75054). Thank You for purchasing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life. This manual contains the information needed to properly install this appliance, and to use, care for and maintain or repair the appliance in a manner which will ensure its optimum performance. WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 3 INSTALLATION INSTRUCTIONS 5 AGENCY APPROVAL INFORMATION 5 OPERATION 6 USERS GUIDE 7 CLEANING INSTRUCTIONS 8 SERVICING INSTRUCTIONS Operational Adjustments 9 Electrical 10 Plumbing 12 De-liming Heater Tank 14 Diagnostics & Troubleshooting 15 EXPLODED VIEW & PARTS LIST Airpot Brewer Models 16 Thermal Brewer Models 18 WIRING DIAGRAMS Airpot/Thermal Brewer Models 20 Export 240V thermal/airpot brewer 21 MODEL CONFIGURATION HEIGHT WIDTH OVER ALL DEPTH 2280/2286EX Thermal Brewer 27p (699 mm) 9b(231 mm) 22 D” (575 mm) 2282/2288EX Airpot Brewer 23p (599 mm) 9b(231 mm) 22 D” (575 mm) MODEL WATTS VOLTS HZ. CIRCUIT REQ. WIRE 2286EX 2288EX 3200 240 50/60 HARD WIRED TO BREAKER 2 + GND. SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 1. Brew Indicator Glows during brew cycle, flashes in “Brew Wait” 2. Heat Indicator Glows when heating elements are energized 3. Power Indicator Glows when power is on 5. Brew Switch Press to initiate brew cycle 6. Cancel Switch Press to terminate brew cycle 7. Power Switch Press to turn brewer on or off 8. Hot Water Faucet Dispense up to 2 cups of hot water at a time for tea, etc. 8 LIFT FOR HOT WATER 1 2 3 5 6 7 CONTROL PANEL CONTROL PANEL HOT WATER FAUCET BREW CHAMBER AIRPOT (BREWING POSITION) POSITIONING BRACKET AIRPOT BREWER BREW CHAMBER THERMAL SERVER (BREWING POSITION) NAMEPLATE THERMAL BREWER CONTROL PANEL HOT WATER FAUCET NAMEPLATE 2 PRECAUTIONS AND GENERAL INFORMATION WARNING: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: Injury Hazard All installation procedures must be performed by qualified personnel with full knowledge of all applicable electrical and plumbing codes. Failure could result in property damage and personal injury. WARNING Electric Shock Hazard Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious Injury. WARNING: Burn Hazard This appliance dispenses very hot liquid. Serious bodily injury from scalding can occur from contact with dispensed liquids. This appliance is intended for commercial use only. This appliance is intended for use to brew beverage products for human consumption. No other use is recommended or authorized by the manufacturer or its agents. This appliance is intended for use in commercial establishments, where all operators are familiar with the appliance use, limitations and associated hazards. Operating instructions and warnings must be read and understood by all operators and users. Except as noted, this piece of equipment is made in the USA and has American sizes on hardware. Please note: Metric hardware is us...
Эта инструкция также подходит к моделям:Прочая кухонная техника - 2280 (1.62 mb)
Прочая кухонная техника - 2282 (1.62 mb)
Прочая кухонная техника - 2288EX (1.62 mb)